{"id":9904,"date":"2022-03-10T20:30:51","date_gmt":"2022-03-10T20:30:51","guid":{"rendered":"https:\/\/www.hexorcism.com\/19BP\/sm2565457\/"},"modified":"2022-03-10T20:30:51","modified_gmt":"2022-03-10T20:30:51","slug":"sm2565457","status":"publish","type":"page","link":"https:\/\/www.hexorcism.com\/19BP\/sm2565457\/","title":{"rendered":"EXPANSION VALVE"},"content":{"rendered":"<div class=\"detailsTabContent\">\n<h3 class=\"c1\">EXPANSION VALVE<\/h3>\n<\/div>\n<p>SM2565457<\/p>\n<div class=\"node SERVICE_MANUALS\"><\/p>\n<div class=\"textleft\">\n<div class=\"attr CONTENT content c2\">\n<hr \/>\n<p class=\"servinfo-title-id\" align=\"right\">id071100002000<\/p>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id07110000200001\" id=\"id07110000200001\"><\/a><\/p>\n<p class=\"servinfosub-title\">Purpose<\/p>\n<div class=\"list\">\u2022 The expansion valve atomizes liquid refrigerant to facilitate cooling of the evaporator.<\/div>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id07110000200002\" id=\"id07110000200002\"><\/a><\/p>\n<p class=\"servinfosub-title\">Function<\/p>\n<div class=\"list\">\u2022 The expansion valve reduces the pressure of liquid refrigerant rapidly to facilitate vaporization of the atomized refrigerant at the evaporator, and adjusts the refrigerant amount sent into the evaporator.<\/div>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id07110000200003\" id=\"id07110000200003\"><\/a><\/p>\n<p class=\"servinfosub-title\">Structure\/Construction<\/p>\n<div class=\"list\">\u2022 The expansion valve consists of the following parts:<\/div>\n<dl>\n<dd class=\"list\">\n<div class=\"list\">\u2015 Diaphragm<\/div>\n<div class=\"list\">\u2015 Temperature sensor<\/div>\n<div class=\"list\">\u2015 Shaft<\/div>\n<div class=\"list\">\u2015 Expansion valve body<\/div>\n<div class=\"list\">\u2015 Ball valve<\/div>\n<div class=\"list\">\u2015 Spring<\/div>\n<\/dd>\n<\/dl>\n<table class=\"figure-flame-non table-flame\">\n<tbody>\n<tr>\n<td>\n<table class=\"figure-non-float table-flame\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3uun00002789.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3uun00002789<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id07110000200004\" id=\"id07110000200004\"><\/a><\/p>\n<p class=\"servinfosub-title\">Operation<\/p>\n<div class=\"list\">\u2022 Adjustment of the refrigerant amount supplied to the evaporator is performed by the ball valve opening angle in the expansion valve.<\/div>\n<div class=\"list\">\u2022 The opening angle adjustment is performed according to the balance of the following forces:<\/p>\n<table class=\"figure-flame table-flame\">\n<tbody>\n<tr>\n<td width=\"10mm\"><\/td>\n<td>\n<table class=\"figure-float table-flame\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3uun00002790.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3uun00002790<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<dl>\n<dd class=\"list\">\n<div class=\"list\">\u2015 Refrigerant pressure (Pd) in diaphragm<\/div>\n<div class=\"list\">\u2015 Refrigerant gas pressure (PI) of evaporator under diaphragm<\/div>\n<div class=\"list\">\u2015 Spring force (Fs) pushing up ball valve<\/div>\n<\/dd>\n<\/dl>\n<div class=\"list\">\u2022 If the refrigerant gas temperature from the evaporator increases, the expansion valve increases the amount of refrigerant according to the following operations:<\/p>\n<table class=\"figure-flame table-flame\">\n<tbody>\n<tr>\n<td width=\"10mm\"><\/td>\n<td>\n<table class=\"figure-float table-flame\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3uun00002791.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3uun00002791<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<dl>\n<dd class=\"list\">\n<div class=\"list\">1. The temperature of the temperature sensor tightly sealed against the diaphragm increases.<\/div>\n<div class=\"list\">2. The refrigerant in the diaphragm warms and the Pd increases.<\/div>\n<div class=\"list\">3. If this Pd increases more than PI + Fs, the diaphragm is pressed down.<\/div>\n<div class=\"list\">4. The shaft installed to the temperature sensor end presses down the ball valve.<\/div>\n<div class=\"list\">5. The amount of refrigerant is increased.<\/div>\n<\/dd>\n<\/dl>\n<div class=\"list\">\u2022 If the refrigerant gas temperature from the evaporator decreases, the expansion valve decreases the amount of refrigerant flow according to the following operation:<\/p>\n<table class=\"figure-flame table-flame\">\n<tbody>\n<tr>\n<td width=\"10mm\"><\/td>\n<td>\n<table class=\"figure-float table-flame\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3uun00002792.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3uun00002792<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<dl>\n<dd class=\"list\">\n<div class=\"list\">1. The temperature of the temperature sensor tightly sealed against the diaphragm decreases.<\/div>\n<div class=\"list\">2. The refrigerant temperature in the diaphragm decreases and the Pd decreases.<\/div>\n<div class=\"list\">3. The Pd decreases less than PI + Fs.<\/div>\n<div class=\"list\">4. The ball valve installed to the temperature sensor end is pressed up.<\/div>\n<div class=\"list\">5. The amount of refrigerant is decreased.<\/div>\n<\/dd>\n<\/dl>\n<\/div>\n<div class=\"ATTACHMENTS\"><\/div>\n<div class=\"attr VTOC_FILENAME content c2\"><!--\n                        am3zz0711x2n0000006 --><\/div>\n<div class=\"attr SIE_ID content c2\"><!--\n                        id071100002000.ent --><\/div>\n<p><!--\n*****************************\nERROR: Schema not found. TYPE=META REFERENCEKEY=SERVICE_MANUALS ROOT=null\n*****************************\n--><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>EXPANSION VALVE SM2565457 id071100002000 Purpose \u2022 The expansion valve atomizes liquid refrigerant to facilitate cooling of the evaporator. Function \u2022 The expansion valve reduces the pressure of liquid refrigerant rapidly to facilitate vaporization of the atomized refrigerant at the evaporator, and adjusts the refrigerant amount sent into the evaporator. Structure\/Construction \u2022 The expansion valve consists of the following parts: \u2015 Diaphragm \u2015 Temperature sensor \u2015 Shaft \u2015 Expansion valve body \u2015 Ball valve \u2015 Spring [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-9904","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/9904","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/comments?post=9904"}],"version-history":[{"count":0,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/9904\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/media?parent=9904"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}