{"id":9899,"date":"2022-03-10T20:30:51","date_gmt":"2022-03-10T20:30:51","guid":{"rendered":"https:\/\/www.hexorcism.com\/19BP\/sm2565452\/"},"modified":"2022-03-10T20:30:51","modified_gmt":"2022-03-10T20:30:51","slug":"sm2565452","status":"publish","type":"page","link":"https:\/\/www.hexorcism.com\/19BP\/sm2565452\/","title":{"rendered":"VENTILATION SYSTEM [(US)]"},"content":{"rendered":"<div class=\"detailsTabContent\">\n<h3 class=\"c1\">VENTILATION SYSTEM [(US)]<\/h3>\n<\/div>\n<p>SM2565452<\/p>\n<div class=\"node SERVICE_MANUALS\"><\/p>\n<div class=\"textleft\">\n<div class=\"attr CONTENT content c2\">\n<hr \/>\n<p class=\"servinfo-title-id\" align=\"right\">id0711000010x1<\/p>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id0711000010x101\" id=\"id0711000010x101\"><\/a><\/p>\n<p class=\"servinfosub-title\">Outline<\/p>\n<div class=\"list\">\u2022 The ventilation system adjusts the airflow temperature sent from the blower unit or the air vent mode.<\/div>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id0711000010x102\" id=\"id0711000010x102\"><\/a><\/p>\n<p class=\"servinfosub-title\">Function<\/p>\n<div class=\"list\">\u2022 The ventilation system adjusts the airflow temperature based on the position of the air mix door.<\/div>\n<div class=\"list\">\u2022 The ventilation system adjusts the airflow mode based on the position of the airflow mode door.<\/div>\n<table class=\"figure-flame-non table-flame\">\n<tbody>\n<tr>\n<td>\n<table class=\"figure-non-float table-flame\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzn00008061.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3zzn00008061<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id0711000010x103\" id=\"id0711000010x103\"><\/a><\/p>\n<p class=\"servinfosub-title\">Structure\/Construction<\/p>\n<p><br clear=\"all\" \/><\/p>\n<p><a name=\"id0711000010x104\" id=\"id0711000010x104\"><\/a><\/p>\n<p class=\"topic-title\">Structural View<\/p>\n<table class=\"figure-flame-non table-flame\">\n<tbody>\n<tr>\n<td>\n<table class=\"figure-non-float table-flame\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzn00008062.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3zzn00008062<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id0711000010x105\" id=\"id0711000010x105\"><\/a><\/p>\n<p class=\"servinfosub-title\">Operation<\/p>\n<p><br clear=\"all\" \/><\/p>\n<p><a name=\"id0711000010x106\" id=\"id0711000010x106\"><\/a><\/p>\n<p class=\"topic-title\">Air mix door<\/p>\n<dl>\n<dd>\n<div class=\"list\">1. The air mix actuator operates according to the airflow temperature control of the climate control unit.<\/div>\n<div class=\"list\">2. The air mix door moves in the COLD or HOT direction according to the operation of the air mix actuator.<\/div>\n<div class=\"list\">3. The airflow volume blowing from the evaporator to the heater core changes by the movement of the air mix door, and the temperature of the air which passes is adjusted.<\/div>\n<\/dd>\n<\/dl>\n<table class=\"figure-flame-non table-flame\">\n<tbody>\n<tr>\n<td>\n<table class=\"figure-non-float table-flame\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzn00008063.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3zzn00008063<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<dl>\n<dd>\n<div class=\"list-title\">Dual mode (full-auto air conditioner)<\/div>\n<\/dd>\n<\/dl>\n<dl>\n<dd>\n<div class=\"list\">1. When the DUAL mode is ON, the driver and passenger-side air mix actuators operate independently according to the temperature control dial operation or the automatic control of the climate control unit.<\/div>\n<div class=\"list\">2. The driver and passenger-side air mix doors move independently according to the air mix actuator operation.<\/div>\n<\/dd>\n<\/dl>\n<table class=\"figure-flame-non table-flame\">\n<tbody>\n<tr>\n<td>\n<table class=\"figure-non-float table-flame\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzn00008064.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3zzn00008064<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<dl>\n<dd>\n<div class=\"list\">\u2022 For the DUAL mode, refer to the [CLIMATE CONTROL UNIT]. (See <a href=\"SM2565460\">CLIMATE CONTROL UNIT [FULL-AUTO AIR CONDITIONER (US)]<\/a>.)<\/div>\n<\/dd>\n<\/dl>\n<p><br clear=\"all\" \/><\/p>\n<p><a name=\"id0711000010x107\" id=\"id0711000010x107\"><\/a><\/p>\n<p class=\"topic-title\">Airflow mode door<\/p>\n<dl>\n<dd>\n<div class=\"list\">1. The airflow mode actuator operates according to the airflow mode control of the climate control unit.<\/div>\n<div class=\"list\">2. The airflow mode main link operates according to the airflow mode actuator operation.<\/div>\n<div class=\"list\">3. The airflow mode door moves in the VENT, BI-LEVEL, HEAT, DEF\/HEAT, or DEFROSTER direction according to the airflow mode main link. The air vent changes by the movement of the airflow mode door.<\/div>\n<\/dd>\n<\/dl>\n<table class=\"figure-flame-non table-flame\">\n<tbody>\n<tr>\n<td>\n<table class=\"figure-non-float table-flame\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzn00008065.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3zzn00008065<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<dl>\n<dd>\n<div class=\"list\">\u2022 The airflow distributed by the airflow mode door passes through the duct and the air is blown from each air vent shown in the figure to the cabin.<\/div>\n<\/dd>\n<\/dl>\n<table class=\"figure-flame-non table-flame\">\n<tbody>\n<tr>\n<td>\n<table class=\"figure-non-float table-flame\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzn00008066.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3zzn00008066<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"ATTACHMENTS\"><\/div>\n<div class=\"attr VTOC_FILENAME content c2\"><!--\n                        am3zz071100n0000056 --><\/div>\n<div class=\"attr SIE_ID content c2\"><!--\n                        id0711000010x1.ent --><\/div>\n<p><!--\n*****************************\nERROR: Schema not found. TYPE=META REFERENCEKEY=SERVICE_MANUALS ROOT=null\n*****************************\n--><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>VENTILATION SYSTEM [(US)] SM2565452 id0711000010x1 Outline \u2022 The ventilation system adjusts the airflow temperature sent from the blower unit or the air vent mode. Function \u2022 The ventilation system adjusts the airflow temperature based on the position of the air mix door. \u2022 The ventilation system adjusts the airflow mode based on the position of the airflow mode door. am3zzn00008061 Structure\/Construction Structural View am3zzn00008062 Operation Air mix door 1. The air mix actuator operates according [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-9899","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/9899","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/comments?post=9899"}],"version-history":[{"count":0,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/9899\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/media?parent=9899"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}