{"id":9848,"date":"2022-03-10T20:30:51","date_gmt":"2022-03-10T20:30:51","guid":{"rendered":"https:\/\/www.hexorcism.com\/19BP\/sm2565351\/"},"modified":"2022-03-10T20:30:51","modified_gmt":"2022-03-10T20:30:51","slug":"sm2565351","status":"publish","type":"page","link":"https:\/\/www.hexorcism.com\/19BP\/sm2565351\/","title":{"rendered":"AIR FUEL RATIO (A\/F) SENSOR HEATER CONTROL [SKYACTIV-G (WITHOUT CYLINDER DEACTIVATION (US))]"},"content":{"rendered":"<div class=\"detailsTabContent\">\n<h3 class=\"c1\">AIR FUEL RATIO (A\/F) SENSOR HEATER CONTROL [SKYACTIV-G (WITHOUT CYLINDER DEACTIVATION (US))]<\/h3>\n<\/div>\n<p>SM2565351<\/p>\n<div class=\"node SERVICE_MANUALS\"><\/p>\n<div class=\"textleft\">\n<div class=\"attr CONTENT content c2\">\n<hr \/>\n<p class=\"servinfo-title-id\" align=\"right\">id0140u0785500<\/p>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id0140h478550001\" id=\"id0140h478550001\"><\/a><\/p>\n<p class=\"servinfosub-title\">Outline<\/p>\n<div class=\"list\">\u2022 Based on the control of the A\/F sensor heater, a stabilized oxygen concentration is detected even at low exhaust temperatures, and feedback control of fuel injection even at cold engine start is made possible for improved cold temperature exhaust emission performance.<\/div>\n<div class=\"list\">\u2022 Both emission performance and sensor protection have been improved by duty control of the heater according to engine operation conditions (exhaust gas temperature).<\/div>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id0140h478550002\" id=\"id0140h478550002\"><\/a><\/p>\n<p class=\"servinfosub-title\">Block Diagram<\/p>\n<table class=\"figure-flame-non\">\n<tbody>\n<tr>\n<td>\n<table class=\"figure-non-float\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzn00008280.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3zzn00008280<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id0140h478550003\" id=\"id0140h478550003\"><\/a><\/p>\n<p class=\"servinfosub-title\">Operation<\/p>\n<p><br clear=\"all\" \/><\/p>\n<p><a name=\"id0140h478550004\" id=\"id0140h478550004\"><\/a><\/p>\n<p class=\"topic-title\">Normal control<\/p>\n<dl>\n<dd>\n<div class=\"list\">\u2022 The PCM operates the A\/F sensor based on the following control conditions:<\/div>\n<\/dd>\n<\/dl>\n<p clear=\"all\">\n<table class=\"table-flame\" border=\"1\">\n<thead>\n<tr>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Output duty ratio<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Control condition<\/p>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">0%<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">\u2022 Ignition switched off<\/div>\n<div class=\"list\">\u2022 Engine stopped (excludes engine stop by i-stop control)<\/div>\n<div class=\"list\">\u2022 Engine start (cranking)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">0\u2015100%<\/div>\n<div class=\"tbody\">(Duty ratio determined by measuring the element temperature by the A\/F sensor heater element impedance)<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">\u2022 After engine warm-up (value fluctuates by battery condition, etc.)<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"ATTACHMENTS\"><\/div>\n<div class=\"attr VTOC_FILENAME content c2\"><!--\n                        am3zz0140h4n0000018 --><\/div>\n<div class=\"attr SIE_ID content c2\"><!--\n                        id0140u0785500.ent --><\/div>\n<p><!--\n*****************************\nERROR: Schema not found. TYPE=META REFERENCEKEY=SERVICE_MANUALS ROOT=null\n*****************************\n--><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>AIR FUEL RATIO (A\/F) SENSOR HEATER CONTROL [SKYACTIV-G (WITHOUT CYLINDER DEACTIVATION (US))] SM2565351 id0140u0785500 Outline \u2022 Based on the control of the A\/F sensor heater, a stabilized oxygen concentration is detected even at low exhaust temperatures, and feedback control of fuel injection even at cold engine start is made possible for improved cold temperature exhaust emission performance. \u2022 Both emission performance and sensor protection have been improved by duty control of the heater according to [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-9848","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/9848","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/comments?post=9848"}],"version-history":[{"count":0,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/9848\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/media?parent=9848"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}