{"id":9842,"date":"2022-03-10T20:30:51","date_gmt":"2022-03-10T20:30:51","guid":{"rendered":"https:\/\/www.hexorcism.com\/19BP\/sm2565345\/"},"modified":"2022-03-10T20:30:51","modified_gmt":"2022-03-10T20:30:51","slug":"sm2565345","status":"publish","type":"page","link":"https:\/\/www.hexorcism.com\/19BP\/sm2565345\/","title":{"rendered":"ELECTRIC VARIABLE VALVE TIMING CONTROL [SKYACTIV-G (WITHOUT CYLINDER DEACTIVATION (US))]"},"content":{"rendered":"<div class=\"detailsTabContent\">\n<h3 class=\"c1\">ELECTRIC VARIABLE VALVE TIMING CONTROL [SKYACTIV-G (WITHOUT CYLINDER DEACTIVATION (US))]<\/h3>\n<\/div>\n<p>SM2565345<\/p>\n<div class=\"node SERVICE_MANUALS\"><\/p>\n<div class=\"textleft\">\n<div class=\"attr CONTENT content c2\">\n<hr \/>\n<p class=\"servinfo-title-id\" align=\"right\">id0140u0318100<\/p>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id0140h431810001\" id=\"id0140h431810001\"><\/a><\/p>\n<p class=\"servinfosub-title\">Outline<\/p>\n<div class=\"list\">\u2022 The PCM determines the optimum intake valve timing according to the engine operation conditions, and sends the motor drive signals to the electric variable valve timing driver. With the adoption of the electric drive system, variable intake valve timing can be controlled without any influence from the engine conditions, increasing fuel economy and decreasing pumping losses.<\/div>\n<div class=\"list\">\u2022 Based on the coordination with the hydraulic variable valve timing control and by increasing the amount of overlap during high engine loads, nitrogen oxide (NOx) occurring largely at high temperatures is reduced by re-circulating exhaust gas into the combustion chamber which reduces combustion temperature.<\/div>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id0140h431810002\" id=\"id0140h431810002\"><\/a><\/p>\n<p class=\"servinfosub-title\">Block Diagram<\/p>\n<table class=\"figure-flame-non\">\n<tbody>\n<tr>\n<td>\n<table class=\"figure-non-float\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/atsuzn00000502.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">atsuzn00000502<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id0140h431810003\" id=\"id0140h431810003\"><\/a><\/p>\n<p class=\"servinfosub-title\">Operation<\/p>\n<p><br clear=\"all\" \/><\/p>\n<p><a name=\"id0140h431810004\" id=\"id0140h431810004\"><\/a><\/p>\n<p class=\"topic-title\">Intake valve timing determination<\/p>\n<dl>\n<dd>\n<div class=\"list\">\u2022 The PCM determines the optimum target intake valve timing according to the engine operation conditions, and controls the output duty ratio to the electric variable valve timing driver so that the actual intake valve timing approaches close to the target intake valve timing.<\/div>\n<\/dd>\n<\/dl>\n<dl>\n<dd>\n<div class=\"list-title\">Target valve timing<\/div>\n<\/dd>\n<\/dl>\n<dl>\n<dd>\n<div class=\"list\">\u2022 The target intake valve timing is determined according to the engine speed, charging efficiency, and engine coolant temperature.<\/div>\n<\/dd>\n<\/dl>\n<dl>\n<dd>\n<div class=\"list-title\">Actual valve timing<\/div>\n<\/dd>\n<\/dl>\n<dl>\n<dd>\n<div class=\"list\">\u2022 The actual intake valve timing is calculated by adding a correction, which is based on the electric variable valve timing actuator signal value, to the value calculated by subtracting the cam maximum retard learning value from the standard intake valve timing.<\/div>\n<div class=\"list\">\u2022 The standard intake valve timing is calculated based on the signals from the crankshaft position and camshaft position sensors.<\/div>\n<\/dd>\n<\/dl>\n<dl>\n<dd>\n<div class=\"list-title\">Cam maximum retard learning value<\/div>\n<\/dd>\n<\/dl>\n<dl>\n<dd>\n<div class=\"list\">\u2022 The cam maximum retard learning value is determined by the maximum retard indication output from the PCM and the standard intake valve timing when the standard intake valve timing is stabilized.<\/div>\n<\/dd>\n<\/dl>\n<p><br clear=\"all\" \/><\/p>\n<p><a name=\"id0140h431810005\" id=\"id0140h431810005\"><\/a><\/p>\n<p class=\"topic-title\">Output duty ratio determination<\/p>\n<dl>\n<dd>\n<div class=\"list\">\u2022 The PCM divides the electric variable valve timing motor drive range modes according to the engine operation conditions, and determines the output duty ratio to the electric variable valve timing actuator in each mode.<\/div>\n<\/dd>\n<\/dl>\n<p clear=\"all\">\n<table class=\"table-flame\" border=\"1\">\n<thead>\n<tr>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Mode name<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Control description<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Control conditions<\/p>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Feedback mode<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">\u2022 Continuously monitors the intake valve timing if it matches the target intake valve timing determined according to the engine operation condition, and controls the output duty ratio based on the result.<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">\u2022 Except for energization cut mode and phase holding mode<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Energization cut mode<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">\u2022 If there is any malfunction in the electric variable valve timing driver, the intake valve timing is held at the maximum retard position to stabilize the engine speed.<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">\u2022 Electric variable valve timing driver malfunction<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Phase holding mode<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">\u2022 To improve the startability, the phase of the electric variable valve timing actuator is held at the intermediate position after the engine is stopped.<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">\u2022 After the engine is stopped (Depending on the engine coolant temperature, operates after a certain period has elapsed from when the engine was stopped to suppress heating of the electrical variable valve timing motor.)<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"ATTACHMENTS\"><\/div>\n<div class=\"attr VTOC_FILENAME content c2\"><!--\n                        am3zz0140h4n0000032 --><\/div>\n<div class=\"attr SIE_ID content c2\"><!--\n                        id0140u0318100.ent --><\/div>\n<p><!--\n*****************************\nERROR: Schema not found. TYPE=META REFERENCEKEY=SERVICE_MANUALS ROOT=null\n*****************************\n--><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>ELECTRIC VARIABLE VALVE TIMING CONTROL [SKYACTIV-G (WITHOUT CYLINDER DEACTIVATION (US))] SM2565345 id0140u0318100 Outline \u2022 The PCM determines the optimum intake valve timing according to the engine operation conditions, and sends the motor drive signals to the electric variable valve timing driver. With the adoption of the electric drive system, variable intake valve timing can be controlled without any influence from the engine conditions, increasing fuel economy and decreasing pumping losses. \u2022 Based on the coordination [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-9842","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/9842","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/comments?post=9842"}],"version-history":[{"count":0,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/9842\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/media?parent=9842"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}