{"id":9833,"date":"2022-03-10T20:30:51","date_gmt":"2022-03-10T20:30:51","guid":{"rendered":"https:\/\/www.hexorcism.com\/19BP\/sm2565336\/"},"modified":"2022-03-10T20:30:51","modified_gmt":"2022-03-10T20:30:51","slug":"sm2565336","status":"publish","type":"page","link":"https:\/\/www.hexorcism.com\/19BP\/sm2565336\/","title":{"rendered":"STARTER CUT-OFF CONTROL [SKYACTIV-G (WITHOUT CYLINDER DEACTIVATION (US))]"},"content":{"rendered":"<div class=\"detailsTabContent\">\n<h3 class=\"c1\">STARTER CUT-OFF CONTROL [SKYACTIV-G (WITHOUT CYLINDER DEACTIVATION (US))]<\/h3>\n<\/div>\n<p>SM2565336<\/p>\n<div class=\"node SERVICE_MANUALS\"><\/p>\n<div class=\"textleft\">\n<div class=\"attr CONTENT content c2\">\n<hr \/>\n<p class=\"servinfo-title-id\" align=\"right\">id0140u0204700<\/p>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id0140h420470001\" id=\"id0140h420470001\"><\/a><\/p>\n<p class=\"servinfosub-title\">Outline<\/p>\n<div class=\"list\">\u2022 The PCM controls energization to the starter relay according to an immobilizer system request to improve security.<\/div>\n<div class=\"list\">\u2022 While not in P or N position, the starter relay energization by the ignition key is inhibited.<\/div>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id0140h420470002\" id=\"id0140h420470002\"><\/a><\/p>\n<p class=\"servinfosub-title\">Block Diagram<\/p>\n<table class=\"figure-flame-non\">\n<tbody>\n<tr>\n<td>\n<table class=\"figure-non-float\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzn00008277.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3zzn00008277<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id0140h420470003\" id=\"id0140h420470003\"><\/a><\/p>\n<p class=\"servinfosub-title\">Operation<\/p>\n<div class=\"list-title\">When engine stop request signal received<\/div>\n<div class=\"list\">\u2022 The PCM does not establish a ground with the starter circuit. Therefore, even if the ignition is switched ON (START), the starter motor does not rotate because the starter relay is not energized, and the engine does not start.<\/div>\n<div class=\"list-title\">When engine stop request signal not received<\/div>\n<div class=\"list\">\u2022 The PCM establishes a ground with the starter circuit. Therefore, when the ignition is switched ON (START), the starter relay is energized and the starter motor rotates. As a result, the engine starts normally.<\/div>\n<table class=\"figure-flame-non\">\n<tbody>\n<tr>\n<td>\n<table class=\"figure-non-float\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/atsuzn00000504.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">atsuzn00000504<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"list\">\u2022 The PCM turns the starter relay off with the engine speed at the set value or more (value from engine coolant temperature fluctuates).<\/div>\n<\/div>\n<div class=\"ATTACHMENTS\"><\/div>\n<div class=\"attr VTOC_FILENAME content c2\"><!--\n                        am3zz0140h4n0000016 --><\/div>\n<div class=\"attr SIE_ID content c2\"><!--\n                        id0140u0204700.ent --><\/div>\n<p><!--\n*****************************\nERROR: Schema not found. TYPE=META REFERENCEKEY=SERVICE_MANUALS ROOT=null\n*****************************\n--><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>STARTER CUT-OFF CONTROL [SKYACTIV-G (WITHOUT CYLINDER DEACTIVATION (US))] SM2565336 id0140u0204700 Outline \u2022 The PCM controls energization to the starter relay according to an immobilizer system request to improve security. \u2022 While not in P or N position, the starter relay energization by the ignition key is inhibited. Block Diagram am3zzn00008277 Operation When engine stop request signal received \u2022 The PCM does not establish a ground with the starter circuit. Therefore, even if the ignition is [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-9833","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/9833","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/comments?post=9833"}],"version-history":[{"count":0,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/9833\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/media?parent=9833"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}