{"id":9800,"date":"2022-03-10T20:30:50","date_gmt":"2022-03-10T20:30:50","guid":{"rendered":"https:\/\/www.hexorcism.com\/19BP\/sm2565297\/"},"modified":"2022-03-10T20:30:50","modified_gmt":"2022-03-10T20:30:50","slug":"sm2565297","status":"publish","type":"page","link":"https:\/\/www.hexorcism.com\/19BP\/sm2565297\/","title":{"rendered":"CHARGING SYSTEM [SKYACTIV-G (WITHOUT CYLINDER DEACTIVATION (US))]"},"content":{"rendered":"<div class=\"detailsTabContent\">\n<h3 class=\"c1\">CHARGING SYSTEM [SKYACTIV-G (WITHOUT CYLINDER DEACTIVATION (US))]<\/h3>\n<\/div>\n<p>SM2565297<\/p>\n<div class=\"node SERVICE_MANUALS\"><\/p>\n<div class=\"textleft\">\n<div class=\"attr CONTENT content c2\">\n<hr \/>\n<p class=\"servinfo-title-id\" align=\"right\">id0117v0102900<\/p>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id0117v010290001\" id=\"id0117v010290001\"><\/a><\/p>\n<p class=\"servinfosub-title\">CHARGING SYSTEM<\/p>\n<p><br clear=\"all\" \/><\/p>\n<p><a name=\"id0117v010290002\" id=\"id0117v010290002\"><\/a><\/p>\n<p class=\"topic-title\">Outline<\/p>\n<dl>\n<dd>\n<div class=\"list\">\u2022 A generator using two delta connection type stator coils has been adopted.<\/div>\n<\/dd>\n<\/dl>\n<p><br clear=\"all\" \/><\/p>\n<p><a name=\"id0117v010290003\" id=\"id0117v010290003\"><\/a><\/p>\n<p class=\"topic-title\">Structural View<\/p>\n<table class=\"figure-flame-non\">\n<tbody>\n<tr>\n<td>\n<table class=\"figure-non-float\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzn00007321.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3zzn00007321<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><br clear=\"all\" \/><\/p>\n<p><a name=\"id0117v010290004\" id=\"id0117v010290004\"><\/a><\/p>\n<p class=\"topic-title\">Structure<\/p>\n<dl>\n<dd>\n<div class=\"list\">\u2022 Consists of the following parts:<\/div>\n<\/dd>\n<\/dl>\n<p clear=\"all\">\n<table class=\"table-flame\" border=\"1\">\n<tbody>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Battery<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">(See <a href=\"#id0117v010290005\">BATTERY<\/a>.)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Generator<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">(See <a href=\"#id0117v010290008\">GENERATOR<\/a>.)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Charging system warning indication\/Charging system warning light<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">(See <a href=\"#id0117v010290012\">CHARGING SYSTEM WARNING INDICATION\/CHARGING SYSTEM WARNING LIGHT<\/a>.)<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id0117v010290005\" id=\"id0117v010290005\"><\/a><\/p>\n<p class=\"servinfosub-title\">BATTERY<\/p>\n<p><br clear=\"all\" \/><\/p>\n<p><a name=\"id0117v010290006\" id=\"id0117v010290006\"><\/a><\/p>\n<p class=\"topic-title\">Purpose, Function<\/p>\n<dl>\n<dd>\n<div class=\"list\">\u2022 The battery stores electricity generated by the generator. In addition, it supplies power to electronic devices if necessary.<\/div>\n<\/dd>\n<\/dl>\n<p><br clear=\"all\" \/><\/p>\n<p><a name=\"id0117v010290007\" id=\"id0117v010290007\"><\/a><\/p>\n<p class=\"topic-title\">Construction<\/p>\n<dl>\n<dd>\n<div class=\"list\">\u2022 The battery is installed in the engine compartment. (vehicle left)<\/p>\n<table class=\"figure-flame\">\n<tbody>\n<tr>\n<td width=\"10mm\"><\/td>\n<td>\n<table class=\"figure-float\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzn00008212.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3zzn00008212<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/dd>\n<\/dl>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id0117v010290008\" id=\"id0117v010290008\"><\/a><\/p>\n<p class=\"servinfosub-title\">GENERATOR<\/p>\n<p><br clear=\"all\" \/><\/p>\n<p><a name=\"id0117v010290009\" id=\"id0117v010290009\"><\/a><\/p>\n<p class=\"topic-title\">Purpose, Function<\/p>\n<dl>\n<dd>\n<div class=\"list\">\u2022 The generator operates by obtaining drive force from the engine via the drive belt and generates the required electricity for electronic devices.<\/div>\n<\/dd>\n<\/dl>\n<p><br clear=\"all\" \/><\/p>\n<p><a name=\"id0117v010290010\" id=\"id0117v010290010\"><\/a><\/p>\n<p class=\"topic-title\">Construction<\/p>\n<dl>\n<dd>\n<div class=\"list\">\u2022 The generator is installed on the engine left front side.<\/p>\n<table class=\"figure-flame\">\n<tbody>\n<tr>\n<td width=\"10mm\"><\/td>\n<td>\n<table class=\"figure-float\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzn00008213.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3zzn00008213<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"list\">\u2022 Two delta connection type stator coils have been adopted.<\/p>\n<table class=\"figure-flame-non\">\n<tbody>\n<tr>\n<td>\n<table class=\"figure-non-float\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzn00006923.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3zzn00006923<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table class=\"figure-flame-non\">\n<tbody>\n<tr>\n<td>\n<table class=\"figure-non-float\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzn00007887.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3zzn00007887<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/dd>\n<\/dl>\n<dl>\n<dd>\n<div class=\"list\">\u2022 The two stator coils form the circuit having a phase difference, and magnetic pull, which operates between the rotor and stator coil by the phase difference, is theoretically eliminated. Due to this, electromagnetic vibration and generator operation noise (electromagnetic noise) have been reduced.<\/p>\n<table class=\"figure-flame\">\n<tbody>\n<tr>\n<td width=\"10mm\"><\/td>\n<td>\n<table class=\"figure-float\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3uun00001931.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3uun00001931<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/dd>\n<\/dl>\n<dl>\n<dd>\n<div class=\"list\">\u2022 Pulsation occurring through voltage rectifying using two stator coils having a phase difference is minimized and stable voltage output is supplied.<\/p>\n<table class=\"figure-flame-non\">\n<tbody>\n<tr>\n<td>\n<table class=\"figure-non-float\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3uun00002198.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3uun00002198<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/dd>\n<\/dl>\n<p><br clear=\"all\" \/><\/p>\n<p><a name=\"id0117v010290011\" id=\"id0117v010290011\"><\/a><\/p>\n<p class=\"topic-title\">Operation<\/p>\n<dl>\n<dd>\n<div class=\"list\">\u2022 For generator control details, refer to CONTROL SYSTEM. (See <a href=\"SM2565339\">GENERATOR CONTROL [SKYACTIV-G (WITHOUT CYLINDER DEACTIVATION (US))]<\/a>.)<\/div>\n<\/dd>\n<\/dl>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id0117v010290012\" id=\"id0117v010290012\"><\/a><\/p>\n<p class=\"servinfosub-title\">CHARGING SYSTEM WARNING INDICATION\/CHARGING SYSTEM WARNING LIGHT<\/p>\n<div class=\"list-title\">Purpose, Function<\/div>\n<div class=\"list\">\u2022 Warns the driver of a charging system malfunction.<\/div>\n<dl>\n<dd class=\"list\">\n<div class=\"list\">\u2015 For details on DTCs which illuminate the charging system warning indication\/charging system warning light, refer to \u201cworkshop manual\u201d.<\/div>\n<\/dd>\n<\/dl>\n<div class=\"list-title\">Construction<\/div>\n<div class=\"list\">\u2022 The charging system warning indication\/charging system warning light is built into the instrument cluster. (See <a href=\"SM2515111\">INSTRUMENT CLUSTER [(US)]<\/a>.)<\/p>\n<table class=\"figure-flame\">\n<tbody>\n<tr>\n<td width=\"10mm\"><\/td>\n<td>\n<table class=\"figure-float\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzn00009697.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3zzn00009697<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"list-title\">Operation<\/div>\n<div class=\"list\">\u2022 Illuminates when a malfunction occurs in the charging system and a DTC is stored in the PCM.<\/div>\n<div class=\"list\">\u2022 A warning message in the center display is displayed when the charging system warning indication\/charging system warning light is turned on. For the message content and verification method, refer to the CENTER DISPLAY in the workshop manual.<\/div>\n<div class=\"list\">\u2022 A warning message in the active driving display is displayed when the charging system warning indication\/charging system warning light is turned on. For the message content and verification method, refer to the ACTIVE DRIVING DISPLAY. (See <a href=\"SM2334292\">ACTIVE DRIVING DISPLAY<\/a>.)<\/div>\n<\/div>\n<div class=\"ATTACHMENTS\"><\/div>\n<div class=\"attr VTOC_FILENAME content c2\"><!--\n                        am3zz0117v0n0000001 --><\/div>\n<div class=\"attr SIE_ID content c2\"><!--\n                        id0117v0102900.ent --><\/div>\n<p><!--\n*****************************\nERROR: Schema not found. TYPE=META REFERENCEKEY=SERVICE_MANUALS ROOT=null\n*****************************\n--><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>CHARGING SYSTEM [SKYACTIV-G (WITHOUT CYLINDER DEACTIVATION (US))] SM2565297 id0117v0102900 CHARGING SYSTEM Outline \u2022 A generator using two delta connection type stator coils has been adopted. Structural View am3zzn00007321 Structure \u2022 Consists of the following parts: Battery (See BATTERY.) Generator (See GENERATOR.) Charging system warning indication\/Charging system warning light (See CHARGING SYSTEM WARNING INDICATION\/CHARGING SYSTEM WARNING LIGHT.) BATTERY Purpose, Function \u2022 The battery stores electricity generated by the generator. In addition, it supplies power to electronic [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-9800","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/9800","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/comments?post=9800"}],"version-history":[{"count":0,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/9800\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/media?parent=9800"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}