{"id":9676,"date":"2022-03-10T20:30:49","date_gmt":"2022-03-10T20:30:49","guid":{"rendered":"https:\/\/www.hexorcism.com\/19BP\/sm2337308\/"},"modified":"2022-03-10T20:30:49","modified_gmt":"2022-03-10T20:30:49","slug":"sm2337308","status":"publish","type":"page","link":"https:\/\/www.hexorcism.com\/19BP\/sm2337308\/","title":{"rendered":"OPERATION USING COMMANDER SWITCH NOT POSSIBLE"},"content":{"rendered":"<div class=\"detailsTabContent\">\n<h3 class=\"c1\">OPERATION USING COMMANDER SWITCH NOT POSSIBLE<\/h3>\n<\/div>\n<p>SM2337308<\/p>\n<div class=\"node SERVICE_MANUALS\"><\/p>\n<div class=\"textleft\">\n<div class=\"attr CONTENT content c2\">\n<hr \/>\n<p class=\"servinfo-title-id\" align=\"right\">id160300001200<\/p>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id16030000120001\" id=\"id16030000120001\"><\/a><\/p>\n<p class=\"servinfosub-title\">Outline<\/p>\n<p clear=\"all\">\n<table class=\"table-flame\" border=\"1\">\n<tbody>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Possible cause<\/div>\n<\/td>\n<td id=\"\" align=\"left\" colspan=\"2\">\n<div class=\"list\">\u2022 Connector or terminal malfunction of the following parts:<\/div>\n<dl>\n<dd class=\"list\">\n<div class=\"list\">\u2015 Commander switch<\/div>\n<div class=\"list\">\u2015 Connectivity master unit (CMU)<\/div>\n<\/dd>\n<\/dl>\n<div class=\"list\">\u2022 Short to power supply, short to ground, or open circuit in commander switch signal circuit<\/div>\n<div class=\"list\">\u2022 Commander switch malfunction<\/div>\n<div class=\"list\">\u2022 Connectivity master unit (CMU) malfunction<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" colspan=\"3\"><img decoding=\"async\" src=\"..\/assets\/bmcozp00000359.png\" \/><\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" colspan=\"2\"><img decoding=\"async\" src=\"..\/assets\/bmcozp00000363.png\" \/><\/td>\n<td id=\"\" align=\"center\"><img decoding=\"async\" src=\"..\/assets\/bmcozp00000364.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id16030000120002\" id=\"id16030000120002\"><\/a><\/p>\n<p class=\"servinfosub-title\">Diagnostic Procedure<\/p>\n<p clear=\"all\">\n<table class=\"table-flame\" border=\"1\">\n<thead>\n<tr>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Step<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Inspection<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Results<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Action<\/p>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">1<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">VERIFY ALL SYSTEM DTCs<\/div>\n<div class=\"list\">\u2022 Perform the DTC inspection. (Refer to the [DTC INSPECTION] in the workshop manual)<\/div>\n<div class=\"list\">\u2022 Are any DTCs displayed?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair the malfunctioning location according to the applicable DTC troubleshooting.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">2<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT COMMANDER SWITCH AND CONNECTIVITY MASTER UNIT (CMU) CONNECTORS FOR MALFUNCTION<\/div>\n<div class=\"list\">\u2022 Inspect the applicable connector and terminal. (Refer to the [CONNECTOR INSPECTION] in the workshop manual)<\/div>\n<div class=\"list\">\u2022 Are the connector and terminal normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location and perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">3<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT COMMANDER SWITCH SIGNAL CIRCUIT FOR SHORT TO POWER SUPPLY, SHORT TO GROUND AND OPEN CIRCUIT<\/div>\n<div class=\"list\">\u2022 Inspect the signal circuit for a short to power supply, short to ground, and an open circuit. (Refer to the [CIRCUIT INSPECTION] in the workshop manual)<\/div>\n<div class=\"list\">\u2022 Is the circuit normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location and perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">4<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT COMMANDER SWITCH FOR MALFUNCTION<\/div>\n<div class=\"list\">\u2022 Inspect the applicable part. (Refer to the [COMMANDER SWITCH INSPECTION] in the workshop manual)<\/div>\n<div class=\"list\">\u2022 Is the part normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location and perform the repair completion verification.<\/div>\n<div class=\"tbody\">(Refer to the [COMMANDER SWITCH REMOVAL\/INSTALLATION] in the workshop manual)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">Repair completion verification<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">VERIFY THAT VEHICLE IS REPAIRED<\/div>\n<div class=\"list\">\u2022 Install\/connect the part removed\/disconnected during the troubleshooting procedure.<\/div>\n<div class=\"list\">\u2022 Has the malfunction symptom been eliminated?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Complete the symptom troubleshooting. (Explain contents of repair to customer)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Refer to the controller area network (CAN) malfunction diagnosis flow to inspect for a CAN communication error.<\/div>\n<div class=\"tbody\">(Refer to the [CONTROLLER AREA NETWORK (CAN) MALFUNCTION DIAGNOSIS FLOW] in the workshop manual)<\/div>\n<div class=\"tbody\">If the CAN communication is normal, perform the diagnosis from Step 1.<\/div>\n<div class=\"list\">\u2022 If the malfunction is not resolved, replace the connectivity master unit (CMU). (Refer to the [CONNECTIVITY MASTER UNIT (CMU) REMOVAL\/INSTALLATION] in the workshop manual)<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"ATTACHMENTS\"><\/div>\n<div class=\"attr VTOC_FILENAME content c2\"><!--\n                        bmcoz160300p0000009 --><\/div>\n<div class=\"attr SIE_ID content c2\"><!--\n                        id160300001200.ent --><\/div>\n<p><!--\n*****************************\nERROR: Schema not found. TYPE=META REFERENCEKEY=SERVICE_MANUALS ROOT=null\n*****************************\n--><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>OPERATION USING COMMANDER SWITCH NOT POSSIBLE SM2337308 id160300001200 Outline Possible cause \u2022 Connector or terminal malfunction of the following parts: \u2015 Commander switch \u2015 Connectivity master unit (CMU) \u2022 Short to power supply, short to ground, or open circuit in commander switch signal circuit \u2022 Commander switch malfunction \u2022 Connectivity master unit (CMU) malfunction Diagnostic Procedure Step Inspection Results Action 1 VERIFY ALL SYSTEM DTCs \u2022 Perform the DTC inspection. (Refer to the [DTC INSPECTION] [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-9676","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/9676","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/comments?post=9676"}],"version-history":[{"count":0,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/9676\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/media?parent=9676"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}