{"id":9663,"date":"2022-03-10T20:30:49","date_gmt":"2022-03-10T20:30:49","guid":{"rendered":"https:\/\/www.hexorcism.com\/19BP\/sm2337192\/"},"modified":"2022-03-10T20:30:49","modified_gmt":"2022-03-10T20:30:49","slug":"sm2337192","status":"publish","type":"page","link":"https:\/\/www.hexorcism.com\/19BP\/sm2337192\/","title":{"rendered":"i-ACTIVSENSE SWITCH INSPECTION"},"content":{"rendered":"<div class=\"detailsTabContent\">\n<h3 class=\"c1\">i-ACTIVSENSE SWITCH INSPECTION<\/h3>\n<\/div>\n<p>SM2337192<\/p>\n<div class=\"node SERVICE_MANUALS\"><\/p>\n<div class=\"textleft\">\n<div class=\"attr CONTENT content c2\">\n<hr \/>\n<p class=\"servinfo-title-id\" align=\"right\">id152000015300<\/p>\n<dl>\n<dd>\n<div class=\"attention3-label\">Note<\/div>\n<\/dd>\n<dd>\n<div class=\"attention3\">\n<div class=\"list\">\u2022 The i-ACTIVSENSE switch is integrated with the cluster switch No.1.<\/div>\n<div class=\"list\">\u2022 For the i-ACTIVSENSE switch switch removal\/installation, refer to CLUSTER SWITCH REMOVAL\/INSTALLATION. (See <a href=\"SM2336513\">CLUSTER SWITCH REMOVAL\/INSTALLATION<\/a>.)<\/div>\n<\/div>\n<\/dd>\n<\/dl>\n<p class=\"list\">1.Disconnect the negative battery terminal. (See <a href=\"SM2565818\">NEGATIVE BATTERY TERMINAL DISCONNECTION\/CONNECTION [(US)]<\/a>.)<\/p>\n<p class=\"list\">\n<p class=\"list\">2.Disconnect the cluster switch No.1 connector. (See <a href=\"SM2336513\">CLUSTER SWITCH REMOVAL\/INSTALLATION<\/a>.)<\/p>\n<p class=\"list\">\n<p class=\"list\">3.Attach the tester lead to the cluster switch No.1 wiring harness-side connector and inspect voltage or continuity according to the Terminal Voltage Table (Reference) on the table.<\/p>\n<p class=\"list\">\n<dl>\n<dd>\n<div class=\"list\">\u2022 If not as specified, repair or replace the related wiring harness.<\/div>\n<div class=\"list\">\u2022 If as specified, replace the cluster switch No.1. (See <a href=\"SM2336513\">CLUSTER SWITCH REMOVAL\/INSTALLATION<\/a>.)<\/div>\n<\/dd>\n<\/dl>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id15200001530001\" id=\"id15200001530001\"><\/a><\/p>\n<p class=\"servinfosub-title\">Terminal Voltage Table (Reference)<\/p>\n<table class=\"figure-flame-non\">\n<tbody>\n<tr>\n<td>\n<table class=\"figure-non-float\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzw00026476.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3zzw00026476<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p clear=\"all\">\n<p>\u2014: Not applicable<\/p>\n<table class=\"table-flame\" border=\"1\">\n<thead>\n<tr>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Terminal<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Connected to<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Test item<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Test condition<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Specification<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Inspection item(s)<\/p>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">A<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Instrument cluster<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Continuity<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Cluster switch No.1 terminal A\u2014Instrument cluster B<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Continuity<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">\u2022 Wiring harness between cluster switch No.1 terminal A and Instrument cluster terminal B<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">B<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"tbody\">IG1 relay No.2<\/div>\n<\/td>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">Voltage<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Ignition is switched ON<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">B+<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"list\">\u2022 Wiring harness between cluster switch No.1 terminal B and IG1 relay No.2 terminal C<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Except above<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">1.0 V or less<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">C<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Instrument cluster<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Continuity<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Cluster switch No.1 terminal C\u2014Instrument cluster AI<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Continuity<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">\u2022 Wiring harness between cluster switch No.1 terminal C and Instrument cluster terminal AI<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">D<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Ground point<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Continuity<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Under any condition<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Continuity<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">\u2022 Wiring harness between cluster switch No.1 terminal D and ground point<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"ATTACHMENTS\"><\/div>\n<div class=\"attr VTOC_FILENAME content c2\"><!--\n                        am3zz152000w0000107 --><\/div>\n<div class=\"attr SIE_ID content c2\"><!--\n                        id152000015300.ent --><\/div>\n<p><!--\n*****************************\nERROR: Schema not found. TYPE=META REFERENCEKEY=SERVICE_MANUALS ROOT=null\n*****************************\n--><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>i-ACTIVSENSE SWITCH INSPECTION SM2337192 id152000015300 Note \u2022 The i-ACTIVSENSE switch is integrated with the cluster switch No.1. \u2022 For the i-ACTIVSENSE switch switch removal\/installation, refer to CLUSTER SWITCH REMOVAL\/INSTALLATION. (See CLUSTER SWITCH REMOVAL\/INSTALLATION.) 1.Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION\/CONNECTION [(US)].) 2.Disconnect the cluster switch No.1 connector. (See CLUSTER SWITCH REMOVAL\/INSTALLATION.) 3.Attach the tester lead to the cluster switch No.1 wiring harness-side connector and inspect voltage or continuity according to the Terminal [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-9663","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/9663","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/comments?post=9663"}],"version-history":[{"count":0,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/9663\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/media?parent=9663"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}