{"id":9660,"date":"2022-03-10T20:30:49","date_gmt":"2022-03-10T20:30:49","guid":{"rendered":"https:\/\/www.hexorcism.com\/19BP\/sm2337188\/"},"modified":"2022-03-10T20:30:49","modified_gmt":"2022-03-10T20:30:49","slug":"sm2337188","status":"publish","type":"page","link":"https:\/\/www.hexorcism.com\/19BP\/sm2337188\/","title":{"rendered":"FRONT RADAR SENSOR INSPECTION"},"content":{"rendered":"<div class=\"detailsTabContent\">\n<h3 class=\"c1\">FRONT RADAR SENSOR INSPECTION<\/h3>\n<\/div>\n<p>SM2337188<\/p>\n<div class=\"node SERVICE_MANUALS\"><\/p>\n<div class=\"textleft\">\n<div class=\"attr CONTENT content c2\">\n<hr \/>\n<p class=\"servinfo-title-id\" align=\"right\">id152000014700<\/p>\n<p class=\"list\">1.Disconnect the negative battery terminal. (See <a href=\"SM2565818\">NEGATIVE BATTERY TERMINAL DISCONNECTION\/CONNECTION [(US)]<\/a>.)<\/p>\n<p class=\"list\">\n<p class=\"list\">2.Remove the front radar sensor. (See <a href=\"SM2337183\">FRONT RADAR SENSOR REMOVAL\/INSTALLATION<\/a>.)<\/p>\n<p class=\"list\">\n<p class=\"list\">3.Connect the front radar sensor connector.<\/p>\n<p class=\"list\">\n<p class=\"list\">4.Connect the negative battery terminal. (See <a href=\"SM2565818\">NEGATIVE BATTERY TERMINAL DISCONNECTION\/CONNECTION [(US)]<\/a>.)<\/p>\n<p class=\"list\">\n<p class=\"list\">5.Verify that the voltages of each of the terminals are as indicated in the terminal voltage table (reference).<\/p>\n<p class=\"list\">\n<dl>\n<dd>\n<div class=\"list\">\u2022 If the voltage is not as specified in the terminal voltage table (reference), inspect the parts under Inspection item(s) and related wiring harnesses.<\/div>\n<dl>\n<dd class=\"list\">\n<div class=\"list\">\u2015 If the system does not operate normally even though the inspection items are normal, replace the front radar sensor. (See <a href=\"SM2337183\">FRONT RADAR SENSOR REMOVAL\/INSTALLATION<\/a>.)<\/div>\n<\/dd>\n<\/dl>\n<\/dd>\n<\/dl>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id15200001470001\" id=\"id15200001470001\"><\/a><\/p>\n<p class=\"servinfosub-title\">Terminal Voltage Table (Reference)<\/p>\n<table class=\"figure-flame-non\">\n<tbody>\n<tr>\n<td>\n<table class=\"figure-non-float\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzw00027434.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3zzw00027434<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p clear=\"all\">\n<table class=\"table-flame\" border=\"1\">\n<thead>\n<tr>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Terminal<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Signal name<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Connected to<\/p>\n<\/th>\n<th id=\"\" align=\"center\" colspan=\"2\">\n<p class=\"thead\">Measurement conditions<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Voltage (V)<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Inspection item(s)<\/p>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">A<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Ground<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Body ground<\/div>\n<\/td>\n<td id=\"\" align=\"left\" colspan=\"2\">\n<div class=\"tbody\">Under any condition<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">1.0 or less<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Related wiring harness<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">B<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<td id=\"\" align=\"center\" colspan=\"2\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">C<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">CAN_L<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">CAN system related module<\/div>\n<\/td>\n<td id=\"\" align=\"left\" colspan=\"4\">\n<div class=\"tbody\">Because this terminal is for communication, determination using terminal voltage inspection is not possible.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">D<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<td id=\"\" align=\"center\" colspan=\"2\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">E<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">CAN_H<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">CAN system related module<\/div>\n<\/td>\n<td id=\"\" align=\"left\" colspan=\"4\">\n<div class=\"tbody\">Because this terminal is for communication, determination using terminal voltage inspection is not possible.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">F<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<td id=\"\" align=\"center\" colspan=\"2\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">G<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<td id=\"\" align=\"center\" colspan=\"2\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">H<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"tbody\">Power position (IG1)<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"tbody\">IG1 relay<\/div>\n<\/td>\n<td id=\"\" align=\"left\" colspan=\"2\">\n<div class=\"tbody\">Ignition switched ON (engine off or on)<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">V <sub>B<\/sub><\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"list\">\u2022 IG1 relay<\/div>\n<div class=\"list\">\u2022 Related wiring harness<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\" colspan=\"2\">\n<div class=\"tbody\">Ignition switched off or ACC<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">1.0 or less<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"ATTACHMENTS\"><\/div>\n<div class=\"attr VTOC_FILENAME content c2\"><!--\n                        am3zz152000w0000102 --><\/div>\n<div class=\"attr SIE_ID content c2\"><!--\n                        id152000014700.ent --><\/div>\n<p><!--\n*****************************\nERROR: Schema not found. TYPE=META REFERENCEKEY=SERVICE_MANUALS ROOT=null\n*****************************\n--><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>FRONT RADAR SENSOR INSPECTION SM2337188 id152000014700 1.Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION\/CONNECTION [(US)].) 2.Remove the front radar sensor. (See FRONT RADAR SENSOR REMOVAL\/INSTALLATION.) 3.Connect the front radar sensor connector. 4.Connect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION\/CONNECTION [(US)].) 5.Verify that the voltages of each of the terminals are as indicated in the terminal voltage table (reference). \u2022 If the voltage is not as specified in the terminal voltage table [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-9660","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/9660","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/comments?post=9660"}],"version-history":[{"count":0,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/9660\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/media?parent=9660"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}