{"id":9270,"date":"2022-03-10T20:30:46","date_gmt":"2022-03-10T20:30:46","guid":{"rendered":"https:\/\/www.hexorcism.com\/19BP\/sm2336306\/"},"modified":"2022-03-10T20:30:46","modified_gmt":"2022-03-10T20:30:46","slug":"sm2336306","status":"publish","type":"page","link":"https:\/\/www.hexorcism.com\/19BP\/sm2336306\/","title":{"rendered":"POWER SEAT SYSTEM DOES NOT OPERATE [POWER SEAT SYSTEM]"},"content":{"rendered":"<div class=\"detailsTabContent\">\n<h3 class=\"c1\">POWER SEAT SYSTEM DOES NOT OPERATE [POWER SEAT SYSTEM]<\/h3>\n<\/div>\n<p>SM2336306<\/p>\n<div class=\"node SERVICE_MANUALS\"><\/p>\n<div class=\"textleft\">\n<div class=\"attr CONTENT content c2\">\n<hr \/>\n<p class=\"servinfo-title-id\" align=\"right\">id0903p4022600<\/p>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id0903p402260001\" id=\"id0903p402260001\"><\/a><\/p>\n<p class=\"servinfosub-title\">Outline<\/p>\n<p clear=\"all\">\n<table class=\"table-flame\" border=\"1\">\n<tbody>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\"><span>Description<\/span><\/div>\n<\/td>\n<td id=\"\" align=\"left\" colspan=\"2\">\n<div class=\"list\">\u2022 The power seat does not operate even though the power seat switch is operated.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Possible cause<\/div>\n<\/td>\n<td id=\"\" align=\"left\" colspan=\"2\">\n<div class=\"list\">\u2022 Connector or terminal malfunction of the following parts:<\/div>\n<dl>\n<dd class=\"list\">\n<div class=\"list\">\u2015 Position memory control module<\/div>\n<div class=\"list\">\u2015 Power seat switch<\/div>\n<\/dd>\n<\/dl>\n<div class=\"list\">\u2022 Short or open circuit to ground in the following wiring harnesses<\/div>\n<dl>\n<dd class=\"list\">\n<div class=\"list\">\u2015 Position memory control module power supply circuit<\/div>\n<div class=\"list\">\u2015 Power seat switch signal circuit<\/div>\n<\/dd>\n<\/dl>\n<div class=\"list\">\u2022 Power seat switch malfunction<\/div>\n<div class=\"list\">\u2022 Position memory control module malfunction<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" colspan=\"3\"><img decoding=\"async\" src=\"..\/assets\/ac30zw00003863.png\" \/><\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" colspan=\"2\"><img decoding=\"async\" src=\"..\/assets\/am3zzw00027477.png\" \/><\/td>\n<td id=\"\" align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzw00027396.png\" \/><\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" colspan=\"3\"><img decoding=\"async\" src=\"..\/assets\/am3zzw00027397.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id0903p402260002\" id=\"id0903p402260002\"><\/a><\/p>\n<p class=\"servinfosub-title\">Diagnostic Procedure<\/p>\n<p clear=\"all\">\n<table class=\"table-flame\" border=\"1\">\n<thead>\n<tr>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Step<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Inspection<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Results<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Action<\/p>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">1<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">VERIFY ALL SYSTEM DTCs<\/div>\n<div class=\"list\">\u2022 Perform the DTC inspection. (See <a href=\"SM2337315\">DTC INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Are any DTCs displayed?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair the malfunctioning location according to the applicable DTC troubleshooting.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">2<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT POSITION MEMORY CONTROL MODULE AND POWER SEAT SWITCH CONNECTORS FOR MALFUNCTION<\/div>\n<div class=\"list\">\u2022 Inspect the applicable connector and terminal. (See <a href=\"SM2337320\">CONNECTOR INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Are the connector and terminal normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location and perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">3<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT POSITION MEMORY CONTROL MODULE POWER SUPPLY CIRCUIT FOR SHORT TO GROUND AND OPEN CIRCUIT<\/div>\n<div class=\"list\">\u2022 Inspect the power supply circuit for a short to ground and open circuit. (See <a href=\"SM2337319\">CIRCUIT INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the circuit normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location and perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">4<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT POWER SEAT SWITCH SIGNAL CIRCUIT FOR SHORT TO GROUND AND OPEN CIRCUIT<\/div>\n<div class=\"list\">\u2022 Inspect the signal circuit for a short to ground and open circuit. (See <a href=\"SM2337319\">CIRCUIT INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the circuit normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location and perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">5<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT POWER SEAT SWITCH FOR MALFUNCTION<\/div>\n<div class=\"list\">\u2022 Inspect the applicable part. (See <a href=\"SM2336395\">POWER SEAT SWITCH INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the part normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location and perform the repair completion verification.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2789493\">POWER SEAT SWITCH REMOVAL\/INSTALLATION [(US)]<\/a>.)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">Repair completion verification<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">VERIFY THAT VEHICLE IS REPAIRED<\/div>\n<div class=\"list\">\u2022 Install\/connect the part removed\/disconnected during the troubleshooting procedure.<\/div>\n<div class=\"list\">\u2022 Has the malfunction symptom been eliminated?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Complete the symptom troubleshooting. (Explain contents of repair to customer)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Refer to the controller area network (CAN) malfunction diagnosis flow to inspect for a CAN communication error.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2566441\">CONTROLLER AREA NETWORK (CAN) MALFUNCTION DIAGNOSIS FLOW [(US)]<\/a>.)<\/div>\n<div class=\"tbody\">If the CAN communication is normal, perform the diagnosis from Step 1.<\/div>\n<div class=\"list\">\u2022 If the malfunction is not resolved, replace the position memory control module. (See <a href=\"SM2763809\">POSITION MEMORY CONTROL MODULE REMOVAL\/INSTALLATION [(US)]<\/a>.)<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"ATTACHMENTS\"><\/div>\n<div class=\"attr VTOC_FILENAME content c2\"><!--\n                        am3zz0903p4w0000004 --><\/div>\n<div class=\"attr SIE_ID content c2\"><!--\n                        id0903p4022600.ent --><\/div>\n<p><!--\n*****************************\nERROR: Schema not found. TYPE=META REFERENCEKEY=SERVICE_MANUALS ROOT=null\n*****************************\n--><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>POWER SEAT SYSTEM DOES NOT OPERATE [POWER SEAT SYSTEM] SM2336306 id0903p4022600 Outline Description \u2022 The power seat does not operate even though the power seat switch is operated. Possible cause \u2022 Connector or terminal malfunction of the following parts: \u2015 Position memory control module \u2015 Power seat switch \u2022 Short or open circuit to ground in the following wiring harnesses \u2015 Position memory control module power supply circuit \u2015 Power seat switch signal circuit \u2022 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-9270","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/9270","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/comments?post=9270"}],"version-history":[{"count":0,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/9270\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/media?parent=9270"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}