{"id":9251,"date":"2022-03-10T20:30:46","date_gmt":"2022-03-10T20:30:46","guid":{"rendered":"https:\/\/www.hexorcism.com\/19BP\/sm2336285\/"},"modified":"2022-03-10T20:30:46","modified_gmt":"2022-03-10T20:30:46","slug":"sm2336285","status":"publish","type":"page","link":"https:\/\/www.hexorcism.com\/19BP\/sm2336285\/","title":{"rendered":"OPERATION USING REMOTE TRANSMITTER BUTTON NOT POSSIBLE [SECURITY AND LOCKS]"},"content":{"rendered":"<div class=\"detailsTabContent\">\n<h3 class=\"c1\">OPERATION USING REMOTE TRANSMITTER BUTTON NOT POSSIBLE [SECURITY AND LOCKS]<\/h3>\n<\/div>\n<p>SM2336285<\/p>\n<div class=\"node SERVICE_MANUALS\"><\/p>\n<div class=\"textleft\">\n<div class=\"attr CONTENT content c2\">\n<hr \/>\n<p class=\"servinfo-title-id\" align=\"right\">id0903k7023200<\/p>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id0903k702320001\" id=\"id0903k702320001\"><\/a><\/p>\n<p class=\"servinfosub-title\">Outline<\/p>\n<p clear=\"all\">\n<table class=\"table-flame\" border=\"1\">\n<tbody>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\"><span>Description<\/span><\/div>\n<\/td>\n<td id=\"\" align=\"left\" colspan=\"2\">\n<div class=\"list\">\u2022 The door lock\/unlock operation using the remote transmitter button is not possible.<\/div>\n<div class=\"list\">\u2022 The trunk open operation using the remote transmitter button is not possible.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Possible cause<\/div>\n<\/td>\n<td id=\"\" align=\"left\" colspan=\"2\">\n<div class=\"list\">\u2022 Remote transmitter malfunction<\/div>\n<div class=\"list\">\u2022 Effect of non-standard equipment (any control unit with built-in micro computer such as radio set, mobile telephone, and TV)<\/div>\n<div class=\"list\">\u2022 Connector or terminal malfunction of the following parts:<\/div>\n<dl>\n<dd class=\"list\">\n<div class=\"list\">\u2015 Keyless receiver<\/div>\n<div class=\"list\">\u2015 LF control module<\/div>\n<\/dd>\n<\/dl>\n<div class=\"list\">\u2022 Short to ground or open circuit in keyless receiver signal circuit<\/div>\n<div class=\"list\">\u2022 Keyless receiver malfunction<\/div>\n<div class=\"list\">\u2022 LF control unit malfunction<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" colspan=\"3\"><img decoding=\"async\" src=\"..\/assets\/am3zzw00026110.png\" \/><\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" colspan=\"2\"><img decoding=\"async\" src=\"..\/assets\/am3zzw00026111.png\" \/><\/td>\n<td id=\"\" align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzw00026112.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id0903k702320002\" id=\"id0903k702320002\"><\/a><\/p>\n<p class=\"servinfosub-title\">Diagnostic Procedure<\/p>\n<p clear=\"all\">\n<table class=\"table-flame\" border=\"1\">\n<thead>\n<tr>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Step<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Inspection<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Results<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Action<\/p>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">1<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">VERIFY ALL SYSTEM DTCs<\/div>\n<div class=\"list\">\u2022 Perform the DTC inspection. (See <a href=\"SM2337315\">DTC INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Are any DTCs displayed?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair the malfunctioning location according to the applicable DTC troubleshooting.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">2<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT REMOTE TRANSMITTER FOR MALFUNCTION<\/div>\n<div class=\"list\">\u2022 Inspect the applicable part. (See <a href=\"SM2336429\">REMOTE TRANSMITTER BATTERY VOLTAGE INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the part normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location and perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">3<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">DETERMINE IF MALFUNCTION CAUSE IS RADIO WAVE DISTURBANCE<\/div>\n<div class=\"list\">\u2022 Did the malfunction occur under the following conditions?<\/div>\n<dl>\n<dd class=\"list\">\n<div class=\"list\">\u2015 Remote transmitter is carried with communication devices such as mobile phone<\/div>\n<div class=\"list\">\u2015 Remote transmitter contacts or is covered by metal object<\/div>\n<div class=\"list\">\u2015 Remote transmitter is near electronic device such as personal computer<\/div>\n<div class=\"list\">\u2015 Non-genuine electronic device is installed<\/div>\n<div class=\"list\">\u2015 There is equipment which discharges radio waves near vehicle<\/div>\n<\/dd>\n<\/dl>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">The system is normal. (Explain to the customer that the operation cannot be performed due to radio wave disturbance.)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">4<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT KEYLESS RECEIVER AND LF CONTROL UNIT CONNECTORS FOR MALFUNCTION<\/div>\n<div class=\"list\">\u2022 Inspect the applicable connector and terminal. (See <a href=\"SM2337320\">CONNECTOR INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Are the connector and terminal normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location and perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">5<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT KEYLESS RECEIVER SIGNAL CIRCUIT FOR SHORT TO GROUND AND OPEN CIRCUIT<\/div>\n<div class=\"list\">\u2022 Inspect the signal circuit for a short to ground and open circuit. (See <a href=\"SM2337319\">CIRCUIT INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the circuit normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location and perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">6<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT KEYLESS RECEIVER FOR MALFUNCTION<\/div>\n<div class=\"list\">\u2022 Inspect the applicable part. (See <a href=\"SM2336450\">KEYLESS RECEIVER INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the part normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location and perform the repair completion verification.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2336449\">KEYLESS RECEIVER REMOVAL\/INSTALLATION<\/a>.)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">Repair completion verification<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">VERIFY THAT VEHICLE IS REPAIRED<\/div>\n<div class=\"list\">\u2022 Install\/connect the part removed\/disconnected during the troubleshooting procedure.<\/div>\n<div class=\"list\">\u2022 Has the malfunction symptom been eliminated?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Complete the symptom troubleshooting. (Explain contents of repair to customer)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Refer to the controller area network (CAN) malfunction diagnosis flow to inspect for a CAN communication error.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2566441\">CONTROLLER AREA NETWORK (CAN) MALFUNCTION DIAGNOSIS FLOW [(US)]<\/a>.)<\/div>\n<div class=\"tbody\">If the CAN communication is normal, perform the diagnosis from Step 1.<\/div>\n<div class=\"list\">\u2022 If the malfunction is not resolved, replace the LF control unit. (See <a href=\"SM2336427\">LF CONTROL UNIT REMOVAL\/INSTALLATION<\/a>.)<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"ATTACHMENTS\"><\/div>\n<div class=\"attr VTOC_FILENAME content c2\"><!--\n                        am3zz0903k7w0000037 --><\/div>\n<div class=\"attr SIE_ID content c2\"><!--\n                        id0903k7023200.ent --><\/div>\n<p><!--\n*****************************\nERROR: Schema not found. TYPE=META REFERENCEKEY=SERVICE_MANUALS ROOT=null\n*****************************\n--><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>OPERATION USING REMOTE TRANSMITTER BUTTON NOT POSSIBLE [SECURITY AND LOCKS] SM2336285 id0903k7023200 Outline Description \u2022 The door lock\/unlock operation using the remote transmitter button is not possible. \u2022 The trunk open operation using the remote transmitter button is not possible. Possible cause \u2022 Remote transmitter malfunction \u2022 Effect of non-standard equipment (any control unit with built-in micro computer such as radio set, mobile telephone, and TV) \u2022 Connector or terminal malfunction of the following parts: [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-9251","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/9251","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/comments?post=9251"}],"version-history":[{"count":0,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/9251\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/media?parent=9251"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}