{"id":9250,"date":"2022-03-10T20:30:46","date_gmt":"2022-03-10T20:30:46","guid":{"rendered":"https:\/\/www.hexorcism.com\/19BP\/sm2336283\/"},"modified":"2022-03-10T20:30:46","modified_gmt":"2022-03-10T20:30:46","slug":"sm2336283","status":"publish","type":"page","link":"https:\/\/www.hexorcism.com\/19BP\/sm2336283\/","title":{"rendered":"TRUNK\/LIFTGATE DOES NOT OPEN [SECURITY AND LOCKS]"},"content":{"rendered":"<div class=\"detailsTabContent\">\n<h3 class=\"c1\">TRUNK\/LIFTGATE DOES NOT OPEN [SECURITY AND LOCKS]<\/h3>\n<\/div>\n<p>SM2336283<\/p>\n<div class=\"node SERVICE_MANUALS\"><\/p>\n<div class=\"textleft\">\n<div class=\"attr CONTENT content c2\">\n<hr \/>\n<p class=\"servinfo-title-id\" align=\"right\">id0903k7023000<\/p>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id0903k702300001\" id=\"id0903k702300001\"><\/a><\/p>\n<p class=\"servinfosub-title\">Outline<\/p>\n<p clear=\"all\">\n<table class=\"table-flame\" border=\"1\">\n<tbody>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\"><span>Description<\/span><\/div>\n<\/td>\n<td id=\"\" align=\"left\" colspan=\"2\">\n<div class=\"list\">\u2022 Trunk\/liftgate does not open even if trunk lid opener switch\/liftgate opener switch is pressed<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Possible cause<\/div>\n<\/td>\n<td id=\"\" align=\"left\" colspan=\"2\">\n<div class=\"list\">\u2022 Connector or terminal malfunction of the following parts:<\/div>\n<dl>\n<dd class=\"list\">\n<div class=\"list\">\u2015 Trunk lid opener switch (4SD)\/liftgate opener switch (5HB)<\/div>\n<div class=\"list\">\u2015 Trunk lid latch and release actuator (4SD)\/liftgate latch and lock actuator (5HB)<\/div>\n<div class=\"list\">\u2015 BCM<\/div>\n<div class=\"list\">\u2015 Electrical Supply Unit<\/div>\n<\/dd>\n<\/dl>\n<div class=\"list\">\u2022 Open circuit in trunk lid opener switch signal circuit (4SD)\/liftgate opener switch signal circuit (5HB)<\/div>\n<div class=\"list\">\u2022 Open circuit in trunk lid opener switch ground circuit (4SD)\/liftgate opener switch ground circuit (5HB)<\/div>\n<div class=\"list\">\u2022 Short to ground or open circuit in trunk lid latch and release actuator signal circuit (4SD)\/liftgate latch and lock actuator signal circuit (5HB)<\/div>\n<div class=\"list\">\u2022 Open circuit in trunk lid latch and release actuator ground circuit (4SD)\/liftgate latch and lock actuator ground circuit (5HB)<\/div>\n<div class=\"list\">\u2022 Trunk lid opener switch (4SD)\/liftgate opener switch (5HB) malfunction<\/div>\n<div class=\"list\">\u2022 Trunk lid latch and release actuator (4SD)\/liftgate latch and lock actuator (5HB) malfunction<\/div>\n<div class=\"list\">\u2022 Electrical supply unit malfunction<\/div>\n<div class=\"list\">\u2022 BCM malfunction<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" colspan=\"3\"><img decoding=\"async\" src=\"..\/assets\/am3zzw00030439.png\" \/><\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" colspan=\"2\"><img decoding=\"async\" src=\"..\/assets\/am3zzw00026098.png\" \/><\/td>\n<td id=\"\" align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzw00026099.png\" \/><\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" colspan=\"2\"><img decoding=\"async\" src=\"..\/assets\/am3zzw00026100.png\" \/><\/td>\n<td id=\"\" align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzw00032985.png\" \/><\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" colspan=\"3\"><img decoding=\"async\" src=\"..\/assets\/am3zzw00026102.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id0903k702300002\" id=\"id0903k702300002\"><\/a><\/p>\n<p class=\"servinfosub-title\">Diagnostic Procedure<\/p>\n<p clear=\"all\">\n<table class=\"table-flame\" border=\"1\">\n<thead>\n<tr>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Step<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Inspection<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Results<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Action<\/p>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">1<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">VERIFY ALL SYSTEM DTCs<\/div>\n<div class=\"list\">\u2022 Perform the DTC inspection. (See <a href=\"SM2337315\">DTC INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Are any DTCs displayed?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair the malfunctioning location according to the applicable DTC troubleshooting.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">2<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT TRUNK LID OPENER SWITCH (4SD)\/LIFTGATE OPENER SWITCH (5HB), TRUNK LID LATCH AND RELEASE ACTUATOR (4SD)\/LIFTGATE LATCH AND LOCK ACTUATOR (5HB), BCM, AND ELECTRICAL SUPPLY UNIT CONNECTORS FOR MALFUNCTION<\/div>\n<div class=\"list\">\u2022 Inspect the applicable connector and terminal. (See <a href=\"SM2337320\">CONNECTOR INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Are the connector and terminal normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location and perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">3<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT TRUNK LID OPENER SWITCH SIGNAL CIRCUIT (4SD)\/LIFTGATE OPENER SWITCH SIGNAL CIRCUIT (5HB) FOR OPEN CIRCUIT<\/div>\n<div class=\"list\">\u2022 Inspect the signal circuit for open circuit (See <a href=\"SM2337319\">CIRCUIT INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the circuit normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location and perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">4<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT TRUNK LID OPENER SWITCH GROUND CIRCUIT (4SD)\/LIFTGATE OPENER SWITCH GROUND CIRCUIT (5HB) FOR OPEN CIRCUIT<\/div>\n<div class=\"list\">\u2022 Inspect the ground circuit for open circuit. (See <a href=\"SM2337319\">CIRCUIT INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the circuit normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location and perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">5<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT TRUNK LID LATCH AND RELEASE ACTUATOR SIGNAL CIRCUIT (4SD)\/LIFTGATE LATCH AND LOCK ACTUATOR SIGNAL CIRCUIT (5HB) FOR SHORT TO GROUND AND OPEN CIRCUIT<\/div>\n<div class=\"list\">\u2022 Inspect the signal circuit for a short to ground and open circuit. (See <a href=\"SM2337319\">CIRCUIT INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the circuit normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location and perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">6<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT TRUNK LID LATCH AND RELEASE ACTUATOR GROUND CIRCUIT (4SD)\/LIFTGATE LATCH AND LOCK ACTUATOR GROUND CIRCUIT (5HB) FOR OPEN CIRCUIT<\/div>\n<div class=\"list\">\u2022 Inspect the ground circuit for open circuit. (See <a href=\"SM2337319\">CIRCUIT INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the circuit normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location and perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">7<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT TRUNK LID OPENER SWITCH (4SD)\/LIFTGATE OPENER SWITCH (5HB) FOR MALFUNCTION<\/div>\n<div class=\"list\">\u2022 Inspect the applicable part. (See <a href=\"SM2336459\">TRUNK LID OPENER SWITCH INSPECTION<\/a>.) (See <a href=\"SM2336457\">LIFTGATE OPENER SWITCH INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the part normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location and perform the repair completion verification.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2336458\">TRUNK LID OPENER SWITCH REMOVAL\/INSTALLATION<\/a>.)<\/div>\n<div class=\"tbody\">(See <a href=\"SM2336456\">LIFTGATE OPENER SWITCH REMOVAL\/INSTALLATION<\/a>.)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">8<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT TRUNK LID LATCH AND RELEASE ACTUATOR (4SD)\/LIFTGATE LATCH AND LOCK ACTUATOR (5HB) FOR MALFUNCTION<\/div>\n<div class=\"list\">\u2022 Inspect the applicable part. (See <a href=\"SM2336447\">TRUNK LID LATCH AND RELEASE ACTUATOR INSPECTION<\/a>.) (See <a href=\"SM2336462\">LIFTGATE LATCH AND LOCK ACTUATOR INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the part normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location and perform the repair completion verification.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2336446\">TRUNK LID LATCH AND RELEASE ACTUATOR REMOVAL\/INSTALLATION<\/a>.)<\/div>\n<div class=\"tbody\">(See <a href=\"SM2336461\">LIFTGATE LATCH AND LOCK ACTUATOR REMOVAL\/INSTALLATION<\/a>.)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">9<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT ELECTRICAL SUPPLY UNIT FOR MALFUNCTION<\/div>\n<div class=\"list\">\u2022 Inspect the applicable part. (See <a href=\"SM2336728\">ELECTRICAL SUPPLY UNIT (ESU) INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the part normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location and perform the repair completion verification.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2336727\">ELECTRICAL SUPPLY UNIT (ESU) REMOVAL\/INSTALLATION<\/a>.)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">Repair completion verification<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">VERIFY THAT VEHICLE IS REPAIRED<\/div>\n<div class=\"list\">\u2022 Install\/connect the part removed\/disconnected during the troubleshooting procedure.<\/div>\n<div class=\"list\">\u2022 Has the malfunction symptom been eliminated?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Complete the symptom troubleshooting. (Explain contents of repair to customer)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Refer to the controller area network (CAN) malfunction diagnosis flow to inspect for a CAN communication error.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2566441\">CONTROLLER AREA NETWORK (CAN) MALFUNCTION DIAGNOSIS FLOW [(US)]<\/a>.)<\/div>\n<div class=\"tbody\">If the CAN communication is normal, perform the diagnosis from Step 1.<\/div>\n<div class=\"list\">\u2022 If the malfunction is not resolved, replace the BCM. (See <a href=\"SM2336729\">BODY CONTROL MODULE (BCM) REMOVAL\/INSTALLATION<\/a>.)<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"ATTACHMENTS\"><\/div>\n<div class=\"attr VTOC_FILENAME content c2\"><!--\n                        am3zz0903k7w0000034 --><\/div>\n<div class=\"attr SIE_ID content c2\"><!--\n                        id0903k7023000.ent --><\/div>\n<p><!--\n*****************************\nERROR: Schema not found. TYPE=META REFERENCEKEY=SERVICE_MANUALS ROOT=null\n*****************************\n--><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>TRUNK\/LIFTGATE DOES NOT OPEN [SECURITY AND LOCKS] SM2336283 id0903k7023000 Outline Description \u2022 Trunk\/liftgate does not open even if trunk lid opener switch\/liftgate opener switch is pressed Possible cause \u2022 Connector or terminal malfunction of the following parts: \u2015 Trunk lid opener switch (4SD)\/liftgate opener switch (5HB) \u2015 Trunk lid latch and release actuator (4SD)\/liftgate latch and lock actuator (5HB) \u2015 BCM \u2015 Electrical Supply Unit \u2022 Open circuit in trunk lid opener switch signal circuit [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-9250","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/9250","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/comments?post=9250"}],"version-history":[{"count":0,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/9250\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/media?parent=9250"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}