{"id":9221,"date":"2022-03-10T20:30:46","date_gmt":"2022-03-10T20:30:46","guid":{"rendered":"https:\/\/www.hexorcism.com\/19BP\/sm2335907\/"},"modified":"2022-03-10T20:30:46","modified_gmt":"2022-03-10T20:30:46","slug":"sm2335907","status":"publish","type":"page","link":"https:\/\/www.hexorcism.com\/19BP\/sm2335907\/","title":{"rendered":"INSPECTION OF SST (DEPLOYMENT TOOL) [TWO-STEP DEPLOYMENT CONTROL SYSTEM &#8211; US\/CANADA SPEC.]"},"content":{"rendered":"<div class=\"detailsTabContent\">\n<h3 class=\"c1\">INSPECTION OF SST (DEPLOYMENT TOOL) [TWO-STEP DEPLOYMENT CONTROL SYSTEM &#8211; US\/CANADA SPEC.]<\/h3>\n<\/div>\n<p>SM2335907<\/p>\n<div class=\"node SERVICE_MANUALS\"><\/p>\n<div class=\"textleft\">\n<div class=\"attr CONTENT content c2\">\n<hr \/>\n<p class=\"servinfo-title-id\" align=\"right\">id0810b4801000<\/p>\n<p class=\"table-title\">Special Service Tool (SST)<\/p>\n<table class=\"table-flame\" border=\"1\">\n<tbody>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">49 H066 002<\/div>\n<div class=\"tbody\"><\/div>\n<div class=\"tbody\">Deployment tool<\/div>\n<\/td>\n<td id=\"\" align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am6xuw00009563.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"list\">1.Before using the <span>SST (49 H066 002)<\/span>, inspect its operation.<\/p>\n<p class=\"list\">\n<table class=\"figure-flame\">\n<tbody>\n<tr>\n<td width=\"10mm\"><\/td>\n<td>\n<table class=\"figure-float\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/ac9uuw00009002.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">ac9uuw00009002<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id0810b480100001\" id=\"id0810b480100001\"><\/a><\/p>\n<p class=\"servinfosub-title\">Inspection Procedure<\/p>\n<p class=\"list\">1.Follow the steps below to inspect the <span>SST (49 H066 002)<\/span>.<\/p>\n<p class=\"list\">\n<table class=\"figure-flame\">\n<tbody>\n<tr>\n<td width=\"10mm\"><\/td>\n<td>\n<table class=\"figure-float\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/ac9uuw00009003.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">ac9uuw00009003<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<dl>\n<dd>\n<div class=\"list\">\u2022 If not as indicated in the table, replace the <span>SST (49 H066 002)<\/span> because it has a malfunction.<\/div>\n<\/dd>\n<\/dl>\n<dl>\n<dd>\n<div class=\"attention1-label\">Warning<\/div>\n<\/dd>\n<dd>\n<div class=\"attention1 list\">\u2022 Do not use a malfunctioning SST (49 H066 002), otherwise it could cause the air bag module or pre-tensioner seat belt to accidentally operate (deploy).<\/div>\n<\/dd>\n<\/dl>\n<dl>\n<dd>\n<div class=\"attention2-label\">Caution<\/div>\n<\/dd>\n<dd>\n<div class=\"attention2 list\">\u2022 Because the permissible voltage for the SST (49 H066 002) is 12 V, do not connect a 24 V power source because it will damage the SST. Always connect only a 12 V power source.<\/div>\n<\/dd>\n<\/dl>\n<table class=\"table-flame\" border=\"1\">\n<thead>\n<tr>\n<th id=\"\" align=\"center\" rowspan=\"2\">\n<p class=\"thead\">Step<\/p>\n<\/th>\n<th id=\"\" align=\"center\" rowspan=\"2\">\n<p class=\"thead\">Inspection procedure<\/p>\n<\/th>\n<th id=\"\" align=\"center\" colspan=\"2\">\n<p class=\"thead\">Light condition<\/p>\n<\/th>\n<\/tr>\n<tr>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Green<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Red<\/p>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">1<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Connect the power supply red clip to the positive battery terminal, and the black clip to the negative battery terminal.<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">On<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Off<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">2<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Connect connectors A and B.<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Off<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">On<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">3<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Press the activation switch.<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">On<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Off<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"ATTACHMENTS\"><\/div>\n<div class=\"attr VTOC_FILENAME content c2\"><!--\n                        am6xu0810b4w0000004 --><\/div>\n<div class=\"attr SIE_ID content c2\"><!--\n                        id0810b4801000.ent --><\/div>\n<p><!--\n*****************************\nERROR: Schema not found. TYPE=META REFERENCEKEY=SERVICE_MANUALS ROOT=null\n*****************************\n--><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>INSPECTION OF SST (DEPLOYMENT TOOL) [TWO-STEP DEPLOYMENT CONTROL SYSTEM &#8211; US\/CANADA SPEC.] SM2335907 id0810b4801000 Special Service Tool (SST) 49 H066 002 Deployment tool 1.Before using the SST (49 H066 002), inspect its operation. ac9uuw00009002 Inspection Procedure 1.Follow the steps below to inspect the SST (49 H066 002). ac9uuw00009003 \u2022 If not as indicated in the table, replace the SST (49 H066 002) because it has a malfunction. Warning \u2022 Do not use a malfunctioning SST [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-9221","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/9221","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/comments?post=9221"}],"version-history":[{"count":0,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/9221\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/media?parent=9221"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}