{"id":9183,"date":"2022-03-10T20:30:45","date_gmt":"2022-03-10T20:30:45","guid":{"rendered":"https:\/\/www.hexorcism.com\/19BP\/sm2335685\/"},"modified":"2022-03-10T20:30:45","modified_gmt":"2022-03-10T20:30:45","slug":"sm2335685","status":"publish","type":"page","link":"https:\/\/www.hexorcism.com\/19BP\/sm2335685\/","title":{"rendered":"INSUFFICIENT AIR (OR NO AIR) BLOWN FROM VENTS [MANUAL AIR CONDITIONER]"},"content":{"rendered":"<div class=\"detailsTabContent\">\n<h3 class=\"c1\">INSUFFICIENT AIR (OR NO AIR) BLOWN FROM VENTS [MANUAL AIR CONDITIONER]<\/h3>\n<\/div>\n<p>SM2335685<\/p>\n<div class=\"node SERVICE_MANUALS\"><\/p>\n<div class=\"textleft\">\n<div class=\"attr CONTENT content c2\">\n<hr \/>\n<p class=\"servinfo-title-id\" align=\"right\">id0703c2700300<\/p>\n<p clear=\"all\">\n<table class=\"table-flame\" border=\"1\">\n<thead>\n<tr>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Troubleshooting item<\/p>\n<\/th>\n<th id=\"\" align=\"left\" colspan=\"2\">\n<p class=\"thead\">Insufficient air (or no air) blown from vents<\/p>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\"><span>Description<\/span><\/div>\n<\/td>\n<td id=\"\" align=\"left\" colspan=\"2\">\n<div class=\"list\">\u2022 Insufficient airflow from vent or duct<\/div>\n<div class=\"list\">\u2022 No airflow from vent or duct<\/div>\n<div class=\"list\">\u2022 Airflow mode does not change<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\"><span>Possible cause<\/span><\/div>\n<\/td>\n<td id=\"\" align=\"left\" colspan=\"2\">\n<div class=\"list\">\u2022 Dash-electrical supply unit detects DTC<\/div>\n<dl>\n<dd class=\"list\">\n<div class=\"list\">\u2015 Detects DTC and activates fail-safe<\/div>\n<\/dd>\n<\/dl>\n<div class=\"list\">\u2022 Blower system malfunction<\/div>\n<div class=\"list\">\u2022 Vent is closed<\/div>\n<div class=\"list\">\u2022 Vent is blocked<\/div>\n<div class=\"list\">\u2022 Duct malfunction<\/div>\n<dl>\n<dd class=\"list\">\n<div class=\"list\">\u2015 Deformation<\/div>\n<div class=\"list\">\u2015 Blockage<\/div>\n<div class=\"list\">\u2015 Air leakage<\/div>\n<div class=\"list\">\u2015 Bad installation<\/div>\n<\/dd>\n<\/dl>\n<div class=\"list\">\u2022 Airflow mode link malfunction<\/div>\n<dl>\n<dd class=\"list\">\n<div class=\"list\">\u2015 Lack of grease<\/div>\n<div class=\"list\">\u2015 Bad installation<\/div>\n<\/dd>\n<\/dl>\n<div class=\"list\">\u2022 Airflow mode actuator malfunction<\/div>\n<div class=\"list\">\u2022 Airflow mode door malfunction<\/div>\n<dl>\n<dd class=\"list\">\n<div class=\"list\">\u2015 Bad installation<\/div>\n<div class=\"list\">\u2015 Damage<\/div>\n<\/dd>\n<\/dl>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p clear=\"all\">\n<p class=\"table-title\">Diagnostic Procedure<\/p>\n<table class=\"table-flame\" border=\"1\">\n<thead>\n<tr>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Step<\/p>\n<\/th>\n<th id=\"\" align=\"center\" colspan=\"2\">\n<p class=\"thead\">Inspection<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Action<\/p>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">1<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">PERFORM DASH-ELECTRICAL SUPPLY UNIT DTC INSPECTION<\/div>\n<div class=\"list\">\u2022 Perform the dash-electrical supply unit DTC inspection using the M-MDS. (See <a href=\"SM2337315\">DTC INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Are any DTCs displayed?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the applicable DTC inspection.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2335558\">DTC TABLE [DASH-ELECTRICAL SUPPLY UNIT (US)]<\/a>.)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">2<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">VERIFY BLOWER MOTOR OPERATION<\/div>\n<div class=\"list\">\u2022 Switch the ignition ON (engine off or on).<\/div>\n<div class=\"list\">\u2022 Set the airflow volume control dial to 1 or more.<\/div>\n<div class=\"list\">\u2022 Does air flow from the vent after operating the blower motor?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the following malfunction symptom item.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2335686\">AMOUNT OF AIR BLOWN FROM VENTS DOES NOT CHANGE [MANUAL AIR CONDITIONER]<\/a>.)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">3<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">VERIFY AIRFLOW CONDITION<\/div>\n<div class=\"list\">\u2022 Does air flow from the vent when the airflow mode is in the VENT mode?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to Step 7.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">4<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">VERIFY VENT CONDITION<\/div>\n<div class=\"list\">\u2022 Is the air vent (right and left\/center) closed?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Open the air vent, then perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">5<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT AIR VENT FOR BLOCKAGE<\/div>\n<div class=\"list\">\u2022 Is the air vent blocked?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Remove the obstruction, then perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">6<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">VERIFY DUCT INSTALLATION CONDITION<\/div>\n<div class=\"list\">\u2022 Is the duct (installed to dashboard) installed to the position correctly and securely? (See <a href=\"SM2336561\">DASHBOARD REMOVAL [(US)]<\/a>.) (See <a href=\"SM2336562\">DASHBOARD INSTALLATION [(US)]<\/a>.)<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Inspect ducts for restriction, deformity, and air leakage, then perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Install the incorrectly installed ducts properly, then perform the repair completion verification.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2336528\">DASHBOARD DISASSEMBLY\/ASSEMBLY [(US)]<\/a>.)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">7<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">VERIFY AIRFLOW CONDITION<\/div>\n<div class=\"list\">\u2022 Does air flow from the vent when the airflow mode is in the HEAT mode?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to Step 10.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">8<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT AIR VENT FOR BLOCKAGE<\/div>\n<div class=\"list\">\u2022 Is the air vent blocked?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Remove the obstruction, then perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">9<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">VERIFY DUCT INSTALLATION CONDITION<\/div>\n<div class=\"list\">\u2022 Is the duct installed to the position correctly and securely? (See <a href=\"SM2335706\">FRONT HEAT DUCT REMOVAL\/INSTALLATION [(US)]<\/a>.) (See <a href=\"SM2335714\">REAR HEAT DUCT REMOVAL\/INSTALLATION [(US)]<\/a>.)<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Inspect ducts for restriction, deformity, and air leakage, then perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Install the incorrectly installed ducts properly, then perform the repair completion verification.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2335706\">FRONT HEAT DUCT REMOVAL\/INSTALLATION [(US)]<\/a>.)<\/div>\n<div class=\"tbody\">(See <a href=\"SM2335714\">REAR HEAT DUCT REMOVAL\/INSTALLATION [(US)]<\/a>.)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">10<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">VERIFY AIRFLOW CONDITION<\/div>\n<div class=\"list\">\u2022 Does air flow from the vent when the airflow mode is in the DEFROSTER mode?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">11<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT AIR VENT FOR BLOCKAGE<\/div>\n<div class=\"list\">\u2022 Is the air vent blocked?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Remove the obstruction, then perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">12<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT AIRFLOW MODE ACTUATOR<\/div>\n<div class=\"list\">\u2022 Inspect the airflow mode actuator. (See <a href=\"SM2566283\">AIRFLOW MODE ACTUATOR INSPECTION [MANUAL AIR CONDITIONER]<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is it normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Replace the airflow mode actuator, then perform the repair completion verification.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2566292\">AIRFLOW MODE ACTUATOR REMOVAL [MANUAL AIR CONDITIONER (US)]<\/a>.)<\/div>\n<div class=\"tbody\">(See <a href=\"SM2566293\">AIRFLOW MODE ACTUATOR INSTALLATION [MANUAL AIR CONDITIONER (US)]<\/a>.)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">13<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT AIRFLOW MODE LINK SET OPERATION<\/div>\n<div class=\"list\">\u2022 Operate the airflow mode link set manually.<\/div>\n<div class=\"list\">\u2022 Does the airflow mode link set operate smoothly?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Replace the airflow mode link set, or airflow mode door, then perform the repair completion verification.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2335709\">A\/C UNIT REMOVAL\/INSTALLATION [(US)]<\/a>.)<\/div>\n<div class=\"tbody\">(See <a href=\"SM2335710\">A\/C UNIT DISASSEMBLY\/ASSEMBLY [(US)]<\/a>.)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">14<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">VERIFY DUCT INSTALLATION CONDITION<\/div>\n<div class=\"list\">\u2022 Is the defroster duct installed to the position correctly and securely? (See <a href=\"SM2336561\">DASHBOARD REMOVAL [(US)]<\/a>.) (See <a href=\"SM2336562\">DASHBOARD INSTALLATION [(US)]<\/a>.)<\/div>\n<div class=\"list\">\u2022 Are the defroster ducts installed properly? (See <a href=\"SM2336561\">DASHBOARD REMOVAL [(US)]<\/a>.) (See <a href=\"SM2336562\">DASHBOARD INSTALLATION [(US)]<\/a>.)<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Inspect ducts for restriction, deformity, and air leakage, then perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Install the incorrectly installed ducts properly, then perform the repair completion verification.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2336561\">DASHBOARD REMOVAL [(US)]<\/a>.)<\/div>\n<div class=\"tbody\">(See <a href=\"SM2336562\">DASHBOARD INSTALLATION [(US)]<\/a>.)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">Repair completion verification<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">VERIFY THAT MALFUNCTION SYMPTOM DOES NOT RECUR AFTER REPAIR<\/div>\n<div class=\"list\">\u2022 Is air discharged from vent?<\/div>\n<div class=\"list\">\u2022 Does air flow from the vent while in each airflow mode?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Troubleshooting completed.<\/div>\n<div class=\"tbody\">Explain repairs to customer.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Refer to the controller area network (CAN) malfunction diagnosis flow to inspect for a CAN communication error.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2566441\">CONTROLLER AREA NETWORK (CAN) MALFUNCTION DIAGNOSIS FLOW [(US)]<\/a>.)<\/div>\n<div class=\"tbody\">If the CAN communication is normal, perform the diagnosis from Step 1.<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"ATTACHMENTS\"><\/div>\n<div class=\"attr VTOC_FILENAME content c2\"><!--\n                        am3zz0703c2w0000082 --><\/div>\n<div class=\"attr SIE_ID content c2\"><!--\n                        id0703c2700300.ent --><\/div>\n<p><!--\n*****************************\nERROR: Schema not found. TYPE=META REFERENCEKEY=SERVICE_MANUALS ROOT=null\n*****************************\n--><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>INSUFFICIENT AIR (OR NO AIR) BLOWN FROM VENTS [MANUAL AIR CONDITIONER] SM2335685 id0703c2700300 Troubleshooting item Insufficient air (or no air) blown from vents Description \u2022 Insufficient airflow from vent or duct \u2022 No airflow from vent or duct \u2022 Airflow mode does not change Possible cause \u2022 Dash-electrical supply unit detects DTC \u2015 Detects DTC and activates fail-safe \u2022 Blower system malfunction \u2022 Vent is closed \u2022 Vent is blocked \u2022 Duct malfunction \u2015 Deformation [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-9183","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/9183","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/comments?post=9183"}],"version-history":[{"count":0,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/9183\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/media?parent=9183"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}