{"id":9177,"date":"2022-03-10T20:30:45","date_gmt":"2022-03-10T20:30:45","guid":{"rendered":"https:\/\/www.hexorcism.com\/19BP\/sm2335678\/"},"modified":"2022-03-10T20:30:45","modified_gmt":"2022-03-10T20:30:45","slug":"sm2335678","status":"publish","type":"page","link":"https:\/\/www.hexorcism.com\/19BP\/sm2335678\/","title":{"rendered":"AIR FROM VENTS NOT COLD ENOUGH [FULL-AUTO AIR CONDITIONER]"},"content":{"rendered":"<div class=\"detailsTabContent\">\n<h3 class=\"c1\">AIR FROM VENTS NOT COLD ENOUGH [FULL-AUTO AIR CONDITIONER]<\/h3>\n<\/div>\n<p>SM2335678<\/p>\n<div class=\"node SERVICE_MANUALS\"><\/p>\n<div class=\"textleft\">\n<div class=\"attr CONTENT content c2\">\n<hr \/>\n<p class=\"servinfo-title-id\" align=\"right\">id0703c1700800<\/p>\n<p clear=\"all\">\n<table class=\"table-flame\" border=\"1\">\n<thead>\n<tr>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Troubleshooting item<\/p>\n<\/th>\n<th id=\"\" align=\"left\" colspan=\"2\">\n<p class=\"thead\">Air from vents not cold enough<\/p>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\"><span>Description<\/span><\/div>\n<\/td>\n<td id=\"\" align=\"left\" colspan=\"2\">\n<div class=\"list\">\u2022 Insufficient cooled-airflow even if airflow temperature setting is MAX COLD<\/div>\n<div class=\"list\">\u2022 Excessive time required to cool to set temperature<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\"><span>Possible cause<\/span><\/div>\n<\/td>\n<td id=\"\" align=\"left\" colspan=\"2\">\n<dl>\n<dd>\n<div class=\"attention3-label\">Note<\/div>\n<\/dd>\n<dd>\n<div class=\"attention3 list\">\u2022 If the engine coolant temperature increases due to a cooling system malfunction, the fail-safe function disables the A\/C operation.<\/div>\n<\/dd>\n<\/dl>\n<div class=\"list\">\u2022 Blower unit or air filter blockage<\/div>\n<div class=\"list\">\u2022 Drive belt malfunction<\/div>\n<div class=\"list\">\u2022 Refrigerant pressure sensor malfunction<\/div>\n<div class=\"list\">\u2022 Cooling fan operation malfunction<\/div>\n<div class=\"list\">\u2022 Condenser fin blockage<\/div>\n<div class=\"list\">\u2022 Expansion valve malfunction<\/div>\n<div class=\"list\">\u2022 Insufficient compressor oil<\/div>\n<div class=\"list\">\u2022 Poor installation of air mix link and air mix door for A\/C unit<\/div>\n<div class=\"list\">\u2022 Air mix actuator malfunction<\/div>\n<div class=\"list\">\u2022 System piping malfunction<\/div>\n<dl>\n<dd class=\"list\">\n<div class=\"list\">\u2015 Crushed piping<\/div>\n<div class=\"list\">\u2015 Gas leakage from connecting area (improper installation, O-ring malfunction)<\/div>\n<\/dd>\n<\/dl>\n<div class=\"list\">\u2022 Condenser malfunction<\/div>\n<div class=\"list\">\u2022 Poor A\/C compressor compression<\/div>\n<div class=\"list\">\u2022 Evaporative temperature sensor malfunction<\/div>\n<div class=\"list\">\u2022 Poor evaporator temperature sensor installation<\/div>\n<div class=\"list\">\u2022 Receiver\/drier malfunction<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p clear=\"all\">\n<p class=\"table-title\">Diagnostic Procedure<\/p>\n<table class=\"table-flame\" border=\"1\">\n<thead>\n<tr>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Step<\/p>\n<\/th>\n<th id=\"\" align=\"center\" colspan=\"2\">\n<p class=\"thead\">Inspection<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Action<\/p>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">1<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT BLOWER UNIT AND AIR FILTER<\/div>\n<div class=\"list\">\u2022 Are the blower unit intake or air filter clogged? (See <a href=\"SM2566251\">AIR FILTER INSPECTION<\/a>.)<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Remove the cause of the blockage.<\/div>\n<div class=\"tbody\">Replace the air filter if it is clogged.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2335707\">AIR FILTER REMOVAL\/INSTALLATION [(US)]<\/a>.)<\/div>\n<div class=\"tbody\">After performing the repair, perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">2<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT REFRIGERANT PRESSURE<\/div>\n<div class=\"list\">\u2022 Inspect the refrigerant pressure. (See <a href=\"SM2566249\">REFRIGERANT PRESSURE CHECK [(US)]<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the refrigerant pressure normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Record the inspection results.<\/div>\n<div class=\"list\">\u2022 If the refrigerant pressures on the high pressure and low pressure side are both high, go to Step 6.<\/div>\n<div class=\"list\">\u2022 If the refrigerant pressures on the high pressure and low pressure sides are almost same, go to Step 9.<\/div>\n<div class=\"list\">\u2022 If the refrigerant pressures on the high pressure and low pressure sides are both low, go to Step 11.<\/div>\n<div class=\"list\">\u2022 If vacuum on the low pressure side and the refrigerant pressure on the high pressure side is extremely low, go to Step 12.<\/div>\n<div class=\"list\">\u2022 If the refrigerant pressure on the high pressure side is low and the refrigerant pressure on the low pressure side is high, replace the A\/C compressor, then perform the repair completion verification. (See <a href=\"SM2335715\">A\/C COMPRESSOR REMOVAL\/INSTALLATION [SKYACTIV-G 2.0, SKYACTIV-G 2.5]<\/a>.)<\/div>\n<div class=\"list\">\u2022 If the refrigerant pressure condition is under any condition other than the above, go to Step 14.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">3<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">PERFORM AIR-CONDITIONING SYSTEM PERFORMANCE TEST<\/div>\n<div class=\"list\">\u2022 Perform the air-conditioning system performance test. (See <a href=\"SM2566247\">REFRIGERANT SYSTEM PERFORMANCE TEST [(US)]<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the airflow temperature within the specified range?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">4<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT DRIVE BELT<\/div>\n<div class=\"list\">\u2022 Inspect the drive belt. (See <a href=\"SM2565610\">DRIVE BELT INSPECTION [SKYACTIV-G (WITHOUT CYLINDER DEACTIVATION (US))]<\/a>.) (See <a href=\"SM2565636\">DRIVE BELT INSPECTION [SKYACTIV-G (WITH CYLINDER DEACTIVATION (US))]<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the drive belt condition normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">After adjusting the drive belt tension, go to the next step.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2565611\">DRIVE BELT REMOVAL\/INSTALLATION [SKYACTIV-G (WITHOUT CYLINDER DEACTIVATION (US))]<\/a>.)<\/div>\n<div class=\"tbody\">(See <a href=\"SM2565637\">DRIVE BELT REMOVAL\/INSTALLATION [SKYACTIV-G (WITH CYLINDER DEACTIVATION (US))]<\/a>.)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">5<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT A\/C PRESSURE SENSOR<\/div>\n<div class=\"list\">\u2022 Inspect the A\/C pressure sensor. (See <a href=\"SM2566274\">REFRIGERANT PRESSURE SENSOR INSPECTION [FULL-AUTO AIR CONDITIONER (US)]<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the A\/C pressure sensor normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Replace the refrigerant pressure sensor.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2566291\">CLIMATE CONTROL UNIT REMOVAL\/INSTALLATION [MANUAL AIR CONDITIONER (US)]<\/a>.)<\/div>\n<div class=\"tbody\">After performing the repair, perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">6<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT COOLING FAN<\/div>\n<div class=\"list\">\u2022 Verify the cooling fan operation. (See <a href=\"SM2565683\">COOLING FAN MOTOR INSPECTION [SKYACTIV-G (WITHOUT CYLINDER DEACTIVATION (US))]<\/a>.) (See <a href=\"SM2565697\">COOLING FAN MOTOR INSPECTION [SKYACTIV-G (WITH CYLINDER DEACTIVATION (US))]<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the cooling fan operation normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location according to the inspection results.<\/div>\n<div class=\"tbody\">After performing the repair, perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">7<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT CONDENSER<\/div>\n<div class=\"list\">\u2022 Inspect the condenser. (See <a href=\"SM2335717\">CONDENSER INSPECTION [SKYACTIV-G 2.0, SKYACTIV-G 2.5]<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is it normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location according to the inspection results.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2335716\">CONDENSER REMOVAL\/INSTALLATION [SKYACTIV-G 2.0, SKYACTIV-G 2.5]<\/a>.)<\/div>\n<div class=\"tbody\">After performing the repair, perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">8<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT SYSTEM PIPING<\/div>\n<div class=\"list\">\u2022 Is the hose on the low pressure side hot to the touch?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Replace the refrigerant.<\/div>\n<div class=\"tbody\">After vacuum discharging for 1 h and charging with refrigerant to the specified level, perform the repair completion verification.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2566248\">REFRIGERANT CHARGING [(US)]<\/a>.)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Replace the refrigerant.<\/div>\n<div class=\"tbody\">After vacuum discharging for <span>15 min<\/span> and charging with refrigerant to the specified level, perform the repair completion verification.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2566248\">REFRIGERANT CHARGING [(US)]<\/a>.)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">9<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT EXPANSION VALVE<\/div>\n<div class=\"list\">\u2022 Remove the expansion valve and verify its condition. (See <a href=\"SM2335711\">EXPANSION VALVE REMOVAL\/INSTALLATION [(US)]<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is there refrigerant leakage or valve blockage?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">If there is foreign matter blockage the valve, remove the foreign matter.<\/div>\n<div class=\"tbody\">If there is refrigerant leakage or blockage, replace the expansion valve.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2335711\">EXPANSION VALVE REMOVAL\/INSTALLATION [(US)]<\/a>.)<\/div>\n<div class=\"tbody\">Perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">10<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">DETERMINE IF MALFUNCTION CAUSE IS A\/C COMPRESSOR OR AIR MIX ACTUATOR<\/div>\n<div class=\"list\">\u2022 Start the engine and idle it.<\/div>\n<div class=\"list\">\u2022 Access the following dash-electrical supply unit PIDs using the M-MDS: (See <a href=\"SM2337317\">PID\/DATA MONITOR INSPECTION<\/a>.)<\/div>\n<dl>\n<dd class=\"list\">\n<div class=\"list\">\u2015 AIR MIX_R<\/div>\n<div class=\"list\">\u2015 AIR MIX_L<\/div>\n<\/dd>\n<\/dl>\n<div class=\"list\">\u2022 Are PID values normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">After adjusting the compressor oil to the specified level, perform the repair completion verification.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2335715\">A\/C COMPRESSOR REMOVAL\/INSTALLATION [SKYACTIV-G 2.0, SKYACTIV-G 2.5]<\/a>.)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Verify the air mix link and air mix door installation conditions on the side where the PID is not normal.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2335709\">A\/C UNIT REMOVAL\/INSTALLATION [(US)]<\/a>.)<\/div>\n<div class=\"tbody\"><span>Securely and correctly installed to positions<\/span><\/div>\n<div class=\"tbody\">Replace the air mix actuator.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2566254\">AIR MIX ACTUATOR REMOVAL [FULL-AUTO AIR CONDITIONER (US)]<\/a>.)<\/div>\n<div class=\"tbody\">(See <a href=\"SM2566275\">AIR MIX ACTUATOR INSTALLATION [FULL-AUTO AIR CONDITIONER (US)]<\/a>.)<\/div>\n<div class=\"tbody\"><span>Not securely and correctly installed to positions<\/span><\/div>\n<div class=\"tbody\">Repair the air mix link and air mix door installation conditions.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2335710\">A\/C UNIT DISASSEMBLY\/ASSEMBLY [(US)]<\/a>.)<\/div>\n<div class=\"tbody\">Perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">11<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT SYSTEM PIPING<\/div>\n<div class=\"list\">\u2022 Verify if there is gas leakage from the system piping using the gas leak tester.<\/div>\n<div class=\"list\">\u2022 Is the system piping normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Replace the crushed system piping or the malfunctioning location.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2335723\">REFRIGERANT LINE REMOVAL\/INSTALLATION [SKYACTIV-G 2.0, SKYACTIV-G 2.5]<\/a>.)<\/div>\n<div class=\"tbody\">Perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Replace the O-ring of the malfunctioning location (system piping connecting area). Or replace the malfunctioning location of the system piping.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2335723\">REFRIGERANT LINE REMOVAL\/INSTALLATION [SKYACTIV-G 2.0, SKYACTIV-G 2.5]<\/a>.)<\/div>\n<div class=\"tbody\">Perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">12<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT REFRIGERANT PRESSURE<\/div>\n<div class=\"list\">\u2022 Does the refrigerant pressure on the low pressure side vary between the vacuum and normal range?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Replace the condenser (moisture has penetrated engine coolant).<\/div>\n<div class=\"tbody\">(See <a href=\"SM2335716\">CONDENSER REMOVAL\/INSTALLATION [SKYACTIV-G 2.0, SKYACTIV-G 2.5]<\/a>.)<\/div>\n<div class=\"tbody\">Perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">13<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT EXPANSION VALVE<\/div>\n<div class=\"list\">\u2022 Remove the expansion valve and verify its condition. (See <a href=\"SM2335711\">EXPANSION VALVE REMOVAL\/INSTALLATION [(US)]<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is there refrigerant leakage or valve blockage?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">If there is foreign matter blockage the valve, remove the foreign matter.<\/div>\n<div class=\"tbody\">If there is refrigerant leakage or blockage, replace the expansion valve.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2335711\">EXPANSION VALVE REMOVAL\/INSTALLATION [(US)]<\/a>.)<\/div>\n<div class=\"tbody\">Perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Install the expansion valve, then perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">14<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT EVAPORATOR TEMPERATURE SENSOR<\/div>\n<div class=\"list\">\u2022 Inspect the evaporator temperature sensor. (See <a href=\"SM2566256\">EVAPORATOR TEMPERATURE SENSOR INSPECTION [FULL-AUTO AIR CONDITIONER]<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the evaporative temperature sensor normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Verify the evaporator temperature installation condition and repair the installation position.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2566255\">EVAPORATOR TEMPERATURE SENSOR REMOVAL\/INSTALLATION [FULL-AUTO AIR CONDITIONER (US)]<\/a>.)<\/div>\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Replace the evaporative temperature sensor.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2566255\">EVAPORATOR TEMPERATURE SENSOR REMOVAL\/INSTALLATION [FULL-AUTO AIR CONDITIONER (US)]<\/a>.)<\/div>\n<div class=\"tbody\">After replacement, perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">15<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">DETERMINE IF MALFUNCTION CAUSE IS A\/C COMPRESSOR OR AIR MIX ACTUATOR<\/div>\n<div class=\"list\">\u2022 Start the engine and idle it.<\/div>\n<div class=\"list\">\u2022 Access the following dash-electrical supply unit PIDs using the M-MDS: (See <a href=\"SM2337317\">PID\/DATA MONITOR INSPECTION<\/a>).<\/div>\n<dl>\n<dd class=\"list\">\n<div class=\"list\">\u2015 AIR MIX_R<\/div>\n<div class=\"list\">\u2015 AIR MIX_L<\/div>\n<\/dd>\n<\/dl>\n<div class=\"list\">\u2022 Are PID values normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Verify the air mix link and air mix door installation conditions on the side where the PID is not normal.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2335709\">A\/C UNIT REMOVAL\/INSTALLATION [(US)]<\/a>.)<\/div>\n<div class=\"tbody\"><span>Securely and correctly installed to positions<\/span><\/div>\n<div class=\"tbody\">Replace the air mix actuator.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2566254\">AIR MIX ACTUATOR REMOVAL [FULL-AUTO AIR CONDITIONER (US)]<\/a>.)<\/div>\n<div class=\"tbody\">(See <a href=\"SM2566275\">AIR MIX ACTUATOR INSTALLATION [FULL-AUTO AIR CONDITIONER (US)]<\/a>.)<\/div>\n<div class=\"tbody\"><span>Not securely and correctly installed to positions<\/span><\/div>\n<div class=\"tbody\">Repair the air mix link and air mix door installation conditions.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2335710\">A\/C UNIT DISASSEMBLY\/ASSEMBLY [(US)]<\/a>.)<\/div>\n<div class=\"tbody\">Perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">Repair completion verification<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">VERIFY THAT MALFUNCTION SYMPTOM DOES NOT RECUR AFTER REPAIR<\/div>\n<div class=\"list\">\u2022 If refrigerant was discharged during inspection and not recharged, perform vacuum discharging and charge with new refrigerant to the specified level. (See <a href=\"SM2566248\">REFRIGERANT CHARGING [(US)]<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is there cool airflow (is the result of refrigerant system performance test normal?) ? (See <a href=\"SM2566247\">REFRIGERANT SYSTEM PERFORMANCE TEST [(US)]<\/a>.)<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Troubleshooting completed.<\/div>\n<div class=\"tbody\">Explain repairs to customer.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Refer to the controller area network (CAN) malfunction diagnosis flow to inspect for a CAN communication error.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2566441\">CONTROLLER AREA NETWORK (CAN) MALFUNCTION DIAGNOSIS FLOW [(US)]<\/a>.)<\/div>\n<div class=\"tbody\">If the CAN communication is normal, perform the diagnosis from Step 1.<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"ATTACHMENTS\"><\/div>\n<div class=\"attr VTOC_FILENAME content c2\"><!--\n                        am3zz0703c1w0000095 --><\/div>\n<div class=\"attr SIE_ID content c2\"><!--\n                        id0703c1700800.ent --><\/div>\n<p><!--\n*****************************\nERROR: Schema not found. TYPE=META REFERENCEKEY=SERVICE_MANUALS ROOT=null\n*****************************\n--><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>AIR FROM VENTS NOT COLD ENOUGH [FULL-AUTO AIR CONDITIONER] SM2335678 id0703c1700800 Troubleshooting item Air from vents not cold enough Description \u2022 Insufficient cooled-airflow even if airflow temperature setting is MAX COLD \u2022 Excessive time required to cool to set temperature Possible cause Note \u2022 If the engine coolant temperature increases due to a cooling system malfunction, the fail-safe function disables the A\/C operation. \u2022 Blower unit or air filter blockage \u2022 Drive belt malfunction \u2022 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-9177","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/9177","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/comments?post=9177"}],"version-history":[{"count":0,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/9177\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/media?parent=9177"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}