{"id":9173,"date":"2022-03-10T20:30:45","date_gmt":"2022-03-10T20:30:45","guid":{"rendered":"https:\/\/www.hexorcism.com\/19BP\/sm2335674\/"},"modified":"2022-03-10T20:30:45","modified_gmt":"2022-03-10T20:30:45","slug":"sm2335674","status":"publish","type":"page","link":"https:\/\/www.hexorcism.com\/19BP\/sm2335674\/","title":{"rendered":"AMOUNT OF AIR BLOWN FROM VENTS DOES NOT CHANGE [FULL-AUTO AIR CONDITIONER]"},"content":{"rendered":"<div class=\"detailsTabContent\">\n<h3 class=\"c1\">AMOUNT OF AIR BLOWN FROM VENTS DOES NOT CHANGE [FULL-AUTO AIR CONDITIONER]<\/h3>\n<\/div>\n<p>SM2335674<\/p>\n<div class=\"node SERVICE_MANUALS\"><\/p>\n<div class=\"textleft\">\n<div class=\"attr CONTENT content c2\">\n<hr \/>\n<p class=\"servinfo-title-id\" align=\"right\">id0703c1700400<\/p>\n<p clear=\"all\">\n<table class=\"table-flame\" border=\"1\">\n<thead>\n<tr>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Troubleshooting item<\/p>\n<\/th>\n<th id=\"\" align=\"left\" colspan=\"2\">\n<p class=\"thead\">Amount of air blown from vents does not change<\/p>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\"><span>Description<\/span><\/div>\n<\/td>\n<td id=\"\" align=\"left\" colspan=\"2\">\n<div class=\"list\">\u2022 Blower motor does not operate even if airflow volume control switch is operated (no airflow from vent)<\/div>\n<div class=\"list\">\u2022 Blower motor operation does not change even if airflow volume control switch is operated (airflow volume from vent does not change)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\"><span>Possible cause<\/span><\/div>\n<\/td>\n<td id=\"\" align=\"left\" colspan=\"2\">\n<div class=\"list\">\u2022 Dash-electrical supply unit detects DTC<\/div>\n<dl>\n<dd class=\"list\">\n<div class=\"list\">\u2015 Detects DTC and activates fail-safe<\/div>\n<\/dd>\n<\/dl>\n<div class=\"list\">\u2022 Blower unit malfunction<\/div>\n<dl>\n<dd class=\"list\">\n<div class=\"list\">\u2015 Blockage<\/div>\n<div class=\"list\">\u2015 Interference between blower motor fan and case<\/div>\n<\/dd>\n<\/dl>\n<div class=\"list\">\u2022 Open circuit in blower motor power supply circuit<\/div>\n<div class=\"list\">\u2022 Short to ground in blower motor power supply circuit<\/div>\n<div class=\"list\">\u2022 Blower motor malfunction<\/div>\n<div class=\"list\">\u2022 Open circuit in blower motor signal circuit<\/div>\n<div class=\"list\">\u2022 Short to ground in blower motor signal circuit<\/div>\n<div class=\"list\">\u2022 Short to power supply in blower motor signal circuit<\/div>\n<div class=\"list\">\u2022 Climate control unit malfunction<\/div>\n<div class=\"list\">\u2022 Blower fan controller (built-in dash-electrical supply unit) malfunction<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" colspan=\"3\"><img decoding=\"async\" src=\"..\/assets\/am3zzw00031394.png\" \/><\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" colspan=\"2\"><img decoding=\"async\" src=\"..\/assets\/am3zzw00030447.png\" \/><\/td>\n<td id=\"\" align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzw00030448.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"list\">\u2022 When performing an asterisked (*) troubleshooting inspection, shake the wiring harness and connectors while performing the inspection to discover whether poor contact points are the cause of any intermittent malfunctions. If there is a problem, inspect make sure connectors, terminals and wiring harnesses are connected correctly and undamaged.<\/div>\n<p clear=\"all\">\n<p class=\"table-title\">Diagnostic Procedure<\/p>\n<table class=\"table-flame\" border=\"1\">\n<thead>\n<tr>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Step<\/p>\n<\/th>\n<th id=\"\" align=\"center\" colspan=\"2\">\n<p class=\"thead\">Inspection<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Action<\/p>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">1<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">PERFORM DASH-ELECTRICAL SUPPLY UNIT DTC INSPECTION<\/div>\n<div class=\"list\">\u2022 Perform the dash-electrical supply unit DTC inspection using the M-MDS. (See <a href=\"SM2337315\">DTC INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Are any DTCs displayed?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the applicable DTC inspection.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2335558\">DTC TABLE [DASH-ELECTRICAL SUPPLY UNIT (US)]<\/a>.)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">2<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT TO SEE WHETHER MALFUNCTION IS IN BLOWER UNIT OR ELSEWHERE<\/div>\n<div class=\"list\">\u2022 Switch the ignition ON (engine off or on).<\/div>\n<div class=\"list\">\u2022 Turn the airflow volume control switch on.<\/div>\n<div class=\"list\">\u2022 Recirculate air inside the vehicle.<\/div>\n<div class=\"list\">\u2022 Does the blower motor rotate?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to Step 4.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">3<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT BLOWER UNIT INTAKE VENT<\/div>\n<div class=\"list\">\u2022 Is blower unit intake vent restricted?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Remove obstruction, then perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Inspect if there are any obstruction in the A\/C unit passage, then perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">4*<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT BLOWER MOTOR POWER SUPPLY CIRCUIT FOR SHORT TO GROUND AND OPEN CIRCUIT<\/div>\n<div class=\"list\">\u2022 Inspect the power supply circuit for an open circuit and short to ground. (See <a href=\"SM2337319\">CIRCUIT INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the circuit normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location and perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">5<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\"><span class=\"entry-title\">INSPECT TO SEE WHETHER MALFUNCTION IS IN BLOWER MOTOR OR ELSEWHERE<\/span><\/div>\n<div class=\"list\">\u2022 Switch the ignition off.<\/div>\n<div class=\"list\">\u2022 Disconnect the negative battery terminal. (See <a href=\"SM2565818\">NEGATIVE BATTERY TERMINAL DISCONNECTION\/CONNECTION [(US)]<\/a>.)<\/div>\n<div class=\"list\">\u2022 Inspect the blower motor. (See <a href=\"SM2335702\">BLOWER MOTOR INSPECTION [(US)]<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the blower motor normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Replace the blower motor, then perform the repair completion verification.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2335701\">BLOWER MOTOR REMOVAL\/INSTALLATION [(US)]<\/a>.)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">6<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT BLOWER MOTOR CONTROL CIRCUIT FOR OPEN CIRCUIT<\/div>\n<div class=\"list\">\u2022 Inspect the applicable circuit for open circuit. (See <a href=\"SM2337319\">CIRCUIT INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the circuit normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location and perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">7<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT BLOWER MOTOR CONTROL CIRCUIT FOR SHORT TO GROUND<\/div>\n<div class=\"list\">\u2022 Inspect the applicable circuit for a short to ground. (See <a href=\"SM2337319\">CIRCUIT INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the circuit normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location and perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">8<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT BLOWER MOTOR CONTROL CIRCUIT FOR SHORT TO POWER SUPPLY<\/div>\n<div class=\"list\">\u2022 Inspect the applicable circuit for a short to power supply. (See <a href=\"SM2337319\">CIRCUIT INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the circuit normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location and perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">Repair completion verification<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">VERIFY THAT MALFUNCTION SYMPTOM DOES NOT RECUR AFTER REPAIR<\/div>\n<div class=\"list\">\u2022 Is air discharged from vent?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Troubleshooting completed.<\/div>\n<div class=\"tbody\">Explain repairs to customer.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Refer to the controller area network (CAN) malfunction diagnosis flow to inspect for a CAN communication error.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2566441\">CONTROLLER AREA NETWORK (CAN) MALFUNCTION DIAGNOSIS FLOW [(US)]<\/a>.)<\/div>\n<div class=\"list\">\u2022 If the CAN communication is normal, replace the climate control unit. (See <a href=\"SM2566269\">CLIMATE CONTROL UNIT REMOVAL\/INSTALLATION [FULL-AUTO AIR CONDITIONER (US)]<\/a>.)<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"ATTACHMENTS\"><\/div>\n<div class=\"attr VTOC_FILENAME content c2\"><!--\n                        am3zz0703c1w0000104 --><\/div>\n<div class=\"attr SIE_ID content c2\"><!--\n                        id0703c1700400.ent --><\/div>\n<p><!--\n*****************************\nERROR: Schema not found. TYPE=META REFERENCEKEY=SERVICE_MANUALS ROOT=null\n*****************************\n--><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>AMOUNT OF AIR BLOWN FROM VENTS DOES NOT CHANGE [FULL-AUTO AIR CONDITIONER] SM2335674 id0703c1700400 Troubleshooting item Amount of air blown from vents does not change Description \u2022 Blower motor does not operate even if airflow volume control switch is operated (no airflow from vent) \u2022 Blower motor operation does not change even if airflow volume control switch is operated (airflow volume from vent does not change) Possible cause \u2022 Dash-electrical supply unit detects DTC \u2015 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-9173","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/9173","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/comments?post=9173"}],"version-history":[{"count":0,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/9173\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/media?parent=9173"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}