{"id":9167,"date":"2022-03-10T20:30:45","date_gmt":"2022-03-10T20:30:45","guid":{"rendered":"https:\/\/www.hexorcism.com\/19BP\/sm2335556\/"},"modified":"2022-03-10T20:30:45","modified_gmt":"2022-03-10T20:30:45","slug":"sm2335556","status":"publish","type":"page","link":"https:\/\/www.hexorcism.com\/19BP\/sm2335556\/","title":{"rendered":"PID\/DATA MONITOR TABLE [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER) (US)]"},"content":{"rendered":"<div class=\"detailsTabContent\">\n<h3 class=\"c1\">PID\/DATA MONITOR TABLE [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER) (US)]<\/h3>\n<\/div>\n<p>SM2335556<\/p>\n<div class=\"node SERVICE_MANUALS\"><\/p>\n<div class=\"textleft\">\n<div class=\"attr CONTENT content c2\">\n<hr \/>\n<p class=\"servinfo-title-id\" align=\"right\">id0702k30114l1<\/p>\n<p clear=\"all\">\n<p>\u2014: Not applicable<\/p>\n<table class=\"table-flame\" border=\"1\">\n<thead>\n<tr>\n<th id=\"\" align=\"center\">\n<p class=\"thead\"><span>PID\/data monitor item<\/span><\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\"><span>Unit\/Operation<\/span><\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\"><span>Data contents<\/span><\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\"><span>Module control terminal<\/span><\/p>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">A\/C_CTRL_STAT<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">OFF\/AC<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">\u2022 OFF: A\/C compressor control is off<\/div>\n<div class=\"list\">\u2022 AC: A\/C compressor control is on<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">A\/C_MAX_SW<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">OFF\/ON<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">\u2022 OFF: Temperature control dial is not rotated to maximum left<\/div>\n<div class=\"list\">\u2022 ON: Temperature control dial is rotated to maximum left<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">A\/C_MODE_BILVL_SW<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">OFF\/ON<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">\u2022 OFF: Mode switch (BI-LEVEL) is not pressed<\/div>\n<div class=\"list\">\u2022 ON: Mode switch (BI-LEVEL) is pressed<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">A\/C_MODE_CTRL_STAT<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Vent\/B\/L\/HEAT\/H\/D\/DEF<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">\u2022 Vent: Airflow mode setting is in VENT<\/div>\n<div class=\"list\">\u2022 B\/L: Airflow mode setting is in BI-LEVEL<\/div>\n<div class=\"list\">\u2022 HEAT: Airflow mode setting is in HEAT<\/div>\n<div class=\"list\">\u2022 H\/D: Airflow mode setting is in DEF\/HEAT<\/div>\n<div class=\"list\">\u2022 DEF: Airflow mode setting is in DEFROSTER<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">A\/C_MODE_FLOOR_DEF_SW<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">OFF\/ON<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">\u2022 OFF: Mode switch (DEF\/HEAT) is not pressed<\/div>\n<div class=\"list\">\u2022 ON: Mode switch (DEF\/HEAT) is pressed<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">A\/C_MODE_FLOOR_SW<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">OFF\/ON<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">\u2022 OFF: Mode switch (HEAT) is not pressed<\/div>\n<div class=\"list\">\u2022 ON: Mode switch (HEAT) is pressed<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">A\/C_MODE_PNL_SW<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">OFF\/ON<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">\u2022 OFF: Mode switch (VENT) is not pressed<\/div>\n<div class=\"list\">\u2022 ON: Mode switch (VENT) is pressed<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">A\/C_SW<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">OFF\/ON<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">\u2022 OFF: A\/C switch is off<\/div>\n<div class=\"list\">\u2022 ON: A\/C switch is on<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">ATC_CTRL<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Displays the air-conditioning control mode condition.<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">CLIMATE_STAT<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Stopped\/IP-ESU Indicater all ON Control\/Indicater all ON Mode<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">\u2022 Stopped: All of the indicators and switch back lights on climate control unit are turned off<\/div>\n<div class=\"list\">\u2022 IP-ESU Indicater all ON Control: All of the indicators and switch back lights on climate control unit are turned on<\/div>\n<div class=\"list\">\u2022 Indicater all ON Mode: While in all indicators on mode<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">CRANKING_STAT<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Displays during engine cranking or other than engine cranking.<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">DEF_SW<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">OFF\/ON<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">\u2022 OFF: DEFROSTER switch is off<\/div>\n<div class=\"list\">\u2022 ON: DEFROSTER switch is on<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">DIM_CANCEL<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Displays the dimmer cancel condition.<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">FAN_CTRL_STAT<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">FAN OFF\/Manual 1\/Manual 2\/Manual 3\/Manual 4\/Manual 5\/Manual 6\/Manual 7<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">\u2022 FAN OFF: Blower motor is stopped<\/div>\n<div class=\"list\">\u2022 Manual 1: Blower motor is operating in manual 1<\/div>\n<div class=\"list\">\u2022 Manual 2: Blower motor is operating in manual 2<\/div>\n<div class=\"list\">\u2022 Manual 3: Blower motor is operating in manual 3<\/div>\n<div class=\"list\">\u2022 Manual 4: Blower motor is operating in manual 4<\/div>\n<div class=\"list\">\u2022 Manual 5: Blower motor is operating in manual 5<\/div>\n<div class=\"list\">\u2022 Manual 6: Blower motor is operating in manual 6<\/div>\n<div class=\"list\">\u2022 Manual 7: Blower motor is operating in manual 7<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">FAN_DIAL_POS<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">FAN OFF\/Manual 1\/Manual 2\/Manual 3\/Manual 4\/Manual 5\/Manual 6\/Manual 7<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">\u2022 FAN OFF: Airflow volume control dial is stopped at fan stop position<\/div>\n<div class=\"list\">\u2022 Manual 1: Airflow volume control dial is stopped at manual 1 position<\/div>\n<div class=\"list\">\u2022 Manual 2: Airflow volume control dial is stopped at manual 2 position<\/div>\n<div class=\"list\">\u2022 Manual 3: Airflow volume control dial is stopped at manual 3 position<\/div>\n<div class=\"list\">\u2022 Manual 4: Airflow volume control dial is stopped at manual 4 position<\/div>\n<div class=\"list\">\u2022 Manual 5: Airflow volume control dial is stopped at manual 5 position<\/div>\n<div class=\"list\">\u2022 Manual 6: Airflow volume control dial is stopped at manual 6 position<\/div>\n<div class=\"list\">\u2022 Manual 7: Airflow volume control dial is stopped at manual 7 position<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">FAN_DIAL_VAL_A\/D<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">LSB<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Displays the A\/D converted value of the airflow volume control dial.<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">GLOVE_BOX_LAMP_CTRL<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">OFF\/ON<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<dl>\n<dd>\n<div class=\"attention3-label\">Note<\/div>\n<\/dd>\n<dd>\n<div class=\"attention3 list\">\u2022 Displays in the M-MDS but it does not operate.<\/div>\n<\/dd>\n<\/dl>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">HZRD_CTRL_STAT<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">OFF\/ON<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">\u2022 OFF: Hazard system is not operating<\/div>\n<div class=\"list\">\u2022 ON: Hazard system is operating<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">HZRD_SW<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">OFF\/ON<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">\u2022 OFF: Hazard warning switch is off<\/div>\n<div class=\"list\">\u2022 ON: Hazard warning switch is on<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">ILLMI_MODE<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Displays the illumination mode.<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">ILLMI_POWER<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Displays the illumination power supply condition.<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">INTAKE_CTRL_STAT<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">REC\/FRESH<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">\u2022 REC: Air intake control setting is in REC<\/div>\n<div class=\"list\">\u2022 FRESH: Air intake control setting is in FRESH<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">PNL_BRIGHT_LVL<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Displays the panel light brightness.<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">POWER_STAT<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Displays the ignition switch condition.<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">R_DEF_CTRL_STAT<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">OFF\/ON<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">\u2022 OFF: Rear window defogger switch indicator is turned off (rear window defogger stopped)<\/div>\n<div class=\"list\">\u2022 ON: Rear window defogger switch indicator is turned on (rear window defogger operating)<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">R_DEF_SW<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">OFF\/ON<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">\u2022 OFF: Rear window defogger switch is off<\/div>\n<div class=\"list\">\u2022 ON: Rear window defogger switch is on<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">REC_SW<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">OFF\/ON<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">\u2022 OFF: RECIRCULATE switch is off<\/div>\n<div class=\"list\">\u2022 ON: RECIRCULATE switch is on<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">ROOM_FUSE_STAT<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Displays the F27 25 A fuse condition.<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">SEAT_HEAT_STAT_L<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">OFF\/Lo\/Mid\/Hi<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">\u2022 OFF: Seat warmer switch (LH) indicator is turned off<\/div>\n<div class=\"list\">\u2022 Lo: Seat warmer switch (LH) indicator is turned on at temperature level 1<\/div>\n<div class=\"list\">\u2022 Mid: Seat warmer switch (LH) indicator is turned on at temperature level 2<\/div>\n<div class=\"list\">\u2022 Hi: Seat warmer switch (LH) indicator is turned on at temperature level 3<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">SEAT_HEAT_STAT_R<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">OFF\/Lo\/Mid\/Hi<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">\u2022 OFF: Seat warmer switch (RH) indicator is turned off<\/div>\n<div class=\"list\">\u2022 Lo: Seat warmer switch (RH) indicator is turned on at temperature level 1<\/div>\n<div class=\"list\">\u2022 Mid: Seat warmer switch (RH) indicator is turned on at temperature level 2<\/div>\n<div class=\"list\">\u2022 Hi: Seat warmer switch (RH) indicator is turned on at temperature level 3<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">SEAT_HEAT_SW_L<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">OFF\/ON<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">\u2022 OFF: Seat warmer switch (LH) is off<\/div>\n<div class=\"list\">\u2022 ON: Seat warmer switch (LH) is on<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">SEAT_HEAT_SW_R<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">OFF\/ON<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">\u2022 OFF: Seat warmer switch (RH) is off<\/div>\n<div class=\"list\">\u2022 ON: Seat warmer switch (RH) is on<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">STR_HEAT_STAT<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">OFF\/Lo<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">\u2022 OFF: Steering warmer switch indicator is turned off<\/div>\n<div class=\"list\">\u2022 Lo: Steering warmer switch indicator is turned on<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">STR_HEAT_SW<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">OFF\/ON<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">\u2022 OFF: Heated steering wheel switch is off<\/div>\n<div class=\"list\">\u2022 ON: Heated steering wheel switch is on<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">TEMP_DIAL_POS<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Displays the position of the temperature control dial.<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">TEMP_DIAL_VAL_A\/D<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">LSB<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Displays the A\/D converted value of the temperature control dial.<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">VOLT_5V<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">V<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Displays the voltage for the 5 V power supply of the circuit in the climate control unit.<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">VPWR<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">V<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Displays the power supply voltage (B+) to the climate control unit.<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"ATTACHMENTS\"><\/div>\n<div class=\"attr VTOC_FILENAME content c2\"><!--\n                        am3zz0702k3w0000019 --><\/div>\n<div class=\"attr SIE_ID content c2\"><!--\n                        id0702k30114l1.ent --><\/div>\n<p><!--\n*****************************\nERROR: Schema not found. TYPE=META REFERENCEKEY=SERVICE_MANUALS ROOT=null\n*****************************\n--><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>PID\/DATA MONITOR TABLE [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER) (US)] SM2335556 id0702k30114l1 \u2014: Not applicable PID\/data monitor item Unit\/Operation Data contents Module control terminal A\/C_CTRL_STAT OFF\/AC \u2022 OFF: A\/C compressor control is off \u2022 AC: A\/C compressor control is on \u2014 A\/C_MAX_SW OFF\/ON \u2022 OFF: Temperature control dial is not rotated to maximum left \u2022 ON: Temperature control dial is rotated to maximum left \u2014 A\/C_MODE_BILVL_SW OFF\/ON \u2022 OFF: Mode switch (BI-LEVEL) is not pressed [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-9167","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/9167","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/comments?post=9167"}],"version-history":[{"count":0,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/9167\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/media?parent=9167"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}