{"id":9136,"date":"2022-03-10T20:30:45","date_gmt":"2022-03-10T20:30:45","guid":{"rendered":"https:\/\/www.hexorcism.com\/19BP\/sm2335503\/"},"modified":"2022-03-10T20:30:45","modified_gmt":"2022-03-10T20:30:45","slug":"sm2335503","status":"publish","type":"page","link":"https:\/\/www.hexorcism.com\/19BP\/sm2335503\/","title":{"rendered":"INDICATOR INSPECTION"},"content":{"rendered":"<div class=\"detailsTabContent\">\n<h3 class=\"c1\">INDICATOR INSPECTION<\/h3>\n<\/div>\n<p>SM2335503<\/p>\n<div class=\"node SERVICE_MANUALS\"><\/p>\n<div class=\"textleft\">\n<div class=\"attr CONTENT content c2\">\n<hr \/>\n<p class=\"servinfo-title-id\" align=\"right\">id051800298300<\/p>\n<dl>\n<dd>\n<div class=\"attention3-label\">Note<\/div>\n<\/dd>\n<dd>\n<div class=\"attention3 list\">\u2022 The indicator is integrated with the shift panel.<\/div>\n<\/dd>\n<\/dl>\n<p class=\"list\">1.Remove the shift panel. (See <a href=\"SM2336563\">SHIFT PANEL REMOVAL\/INSTALLATION<\/a>.)<\/p>\n<p class=\"list\">\n<p class=\"list\">2.Verify that the voltages of each of the terminals are as indicated in the terminal voltage table (reference).<\/p>\n<p class=\"list\">\n<dl>\n<dd>\n<div class=\"list\">\u2022 If the voltage is not as specified in the terminal voltage table (reference), inspect the parts under Inspection item(s) and related wiring harnesses.<\/div>\n<dl>\n<dd class=\"list\">\n<div class=\"list\">\u2015 If the inspection items are normal, replace the shift panel. (See <a href=\"SM2336563\">SHIFT PANEL REMOVAL\/INSTALLATION<\/a>.)<\/div>\n<\/dd>\n<\/dl>\n<\/dd>\n<\/dl>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id05180029830001\" id=\"id05180029830001\"><\/a><\/p>\n<p class=\"servinfosub-title\">Terminal Voltage Table (Reference)<\/p>\n<table class=\"figure-flame\">\n<tbody>\n<tr>\n<td width=\"10mm\"><\/td>\n<td>\n<table class=\"figure-float\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzw00034564.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3zzw00034564<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p clear=\"all\">\n<p>\u2014: Not applicable<\/p>\n<table class=\"table-flame\" border=\"1\">\n<thead>\n<tr>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Terminal<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Connected to<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Test condition<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Voltage (V)<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Inspection item(s)<\/p>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">A<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Battery<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Under any condition<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">B+<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">\u2022 Wiring harness between indicator terminal A and battery positive terminal<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">B<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"tbody\">IG1 relay No.2<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Ignition is switched ON<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">B+<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"list\">\u2022 Wiring harness between indicator terminal B and IG1 relay No.2 terminal C<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Except above<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Below 1.0<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">C<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"tbody\">Selector lever component (shift-lock solenoid)<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">The following conditions are met (except emergency manual shift-lock release system is operated)<\/div>\n<div class=\"list\">\u2015 Selector lever is in P position<\/div>\n<div class=\"list\">\u2015 Ignition is switched to ON<\/div>\n<div class=\"list\">\u2015 Brake pedal is depressed (brake light switch is on)<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Below 1.0<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"list\">\u2022 Wiring harness between indicator terminal C and selector lever component terminal E<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Except above<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">B+<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">D<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">E<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">CAN module<\/div>\n<\/td>\n<td id=\"\" align=\"left\" colspan=\"3\">\n<div class=\"tbody\">This terminal is used for communication and cannot be used for malfunction determination during terminal voltage inspection. Perform a DTC inspection.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">F<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">CAN module<\/div>\n<\/td>\n<td id=\"\" align=\"left\" colspan=\"3\">\n<div class=\"tbody\">This terminal is used for communication and cannot be used for malfunction determination during terminal voltage inspection. Perform a DTC inspection.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">G<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"tbody\">Selector lever component (up switch)<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Selector lever is in the M position (+) side position.<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Below 1.0<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"list\">\u2022 Wiring harness between indicator terminal G and selector lever component terminal F<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Selector lever is not in the M position (+) side position.<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">B+<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">H<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"tbody\">Selector lever component (down switch)<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Selector lever is in the M position (\u2212) side position.<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Below 1.0<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"list\">\u2022 Wiring harness between indicator terminal H and selector lever component terminal D<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Selector lever is not in the M position (\u2212) side position.<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">B+<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">I<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"tbody\">Selector lever component (M position switch)<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Selector lever is in the M position.<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Below 1.0<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"list\">\u2022 Wiring harness between indicator terminal I and selector lever component terminal B<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Selector lever is not in the M position.<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">B+<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">J<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Ground point<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Under any condition<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Approx. 0<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">\u2022 Ground point<\/div>\n<div class=\"list\">\u2022 Wiring harness between indicator terminal J and ground point<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"ATTACHMENTS\"><\/div>\n<div class=\"attr VTOC_FILENAME content c2\"><!--\n                        am3zz051800w0000060 --><\/div>\n<div class=\"attr SIE_ID content c2\"><!--\n                        id051800298300.ent --><\/div>\n<p><!--\n*****************************\nERROR: Schema not found. TYPE=META REFERENCEKEY=SERVICE_MANUALS ROOT=null\n*****************************\n--><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>INDICATOR INSPECTION SM2335503 id051800298300 Note \u2022 The indicator is integrated with the shift panel. 1.Remove the shift panel. (See SHIFT PANEL REMOVAL\/INSTALLATION.) 2.Verify that the voltages of each of the terminals are as indicated in the terminal voltage table (reference). \u2022 If the voltage is not as specified in the terminal voltage table (reference), inspect the parts under Inspection item(s) and related wiring harnesses. \u2015 If the inspection items are normal, replace the shift panel. [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-9136","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/9136","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/comments?post=9136"}],"version-history":[{"count":0,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/9136\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/media?parent=9136"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}