{"id":8973,"date":"2022-03-10T20:30:43","date_gmt":"2022-03-10T20:30:43","guid":{"rendered":"https:\/\/www.hexorcism.com\/19BP\/sm2334590\/"},"modified":"2022-03-10T20:30:43","modified_gmt":"2022-03-10T20:30:43","slug":"sm2334590","status":"publish","type":"page","link":"https:\/\/www.hexorcism.com\/19BP\/sm2334590\/","title":{"rendered":"DTC P0053:00 [PCM (SKYACTIV-G)]"},"content":{"rendered":"<div class=\"detailsTabContent\">\n<h3 class=\"c1\">DTC P0053:00 [PCM (SKYACTIV-G)]<\/h3>\n<\/div>\n<p>SM2334590<\/p>\n<div class=\"node SERVICE_MANUALS\"><\/p>\n<div class=\"textleft\">\n<div class=\"attr CONTENT content c2\">\n<hr \/>\n<p class=\"servinfo-title-id\" align=\"right\">id0102t4933800<\/p>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id0102t493380001\" id=\"id0102t493380001\"><\/a><\/p>\n<p class=\"servinfosub-title\">Outline<\/p>\n<p clear=\"all\">\n<table class=\"table-flame\" border=\"1\">\n<thead>\n<tr>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">System malfunction location<\/p>\n<\/th>\n<th id=\"\" align=\"left\" colspan=\"5\">\n<p class=\"thead\">A\/F sensor heater resistance<\/p>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\"><span>Detection condition<\/span><\/div>\n<\/td>\n<td id=\"\" align=\"left\" colspan=\"5\">\n<div class=\"list\">\u2022 When the PCM controls the A\/F sensor heater, the A\/F sensor element resistance input to the PCM is the specified value or more.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\"><span>Fail-safe<\/span><\/div>\n<\/td>\n<td id=\"\" align=\"left\" colspan=\"5\">\n<div class=\"list\">\u2022 Stops fuel feedback control<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\"><span>Possible cause<\/span><\/div>\n<\/td>\n<td id=\"\" align=\"left\" colspan=\"5\">\n<div class=\"list\">\u2022 A\/F sensor connector or terminals malfunction<\/div>\n<div class=\"list\">\u2022 F8 15 A fuse malfunction<\/div>\n<div class=\"list\">\u2022 Short to ground in A\/F sensor heater power supply circuit<\/div>\n<div class=\"list\">\u2022 Open circuit in A\/F sensor heater power supply circuit<\/div>\n<div class=\"list\">\u2022 A\/F sensor heater malfunction<\/div>\n<div class=\"list\">\u2022 PCM connector or terminals malfunction<\/div>\n<div class=\"list\">\u2022 Open circuit in A\/F sensor heater control circuit<\/div>\n<div class=\"list\">\u2022 Short to ground in A\/F sensor heater control circuit<\/div>\n<div class=\"list\">\u2022 PCM malfunction<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" colspan=\"6\"><img decoding=\"async\" src=\"..\/assets\/am3zzw00033940.png\" \/><\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" colspan=\"3\"><img decoding=\"async\" src=\"..\/assets\/am3zzw00033941.png\" \/><\/td>\n<td id=\"\" align=\"center\" colspan=\"3\"><img decoding=\"async\" src=\"..\/assets\/am3zzw00033942.png\" \/><\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" colspan=\"6\"><img decoding=\"async\" src=\"..\/assets\/am3zzw00033943.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id0102t493380002\" id=\"id0102t493380002\"><\/a><\/p>\n<p class=\"servinfosub-title\">Diagnostic Procedure<\/p>\n<p clear=\"all\">\n<table class=\"table-flame\" border=\"1\">\n<thead>\n<tr>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Step<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Inspection<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Results<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Action<\/p>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">1<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"entry-title\">RECORD VEHICLE STATUS WHEN DTC WAS DETECTED TO UTILIZE WITH REPEATABILITY VERIFICATION<\/div>\n<div class=\"list\">\u2022 Record the freeze frame data\/snapshot data and diagnostic monitoring test results (A\/F sensor heater, HO2S heater related).<\/p>\n<dl>\n<dd>\n<div class=\"attention3-label\">Note<\/div>\n<\/dd>\n<dd>\n<div class=\"attention3 list\">\u2022 Recording can be facilitated using the screen capture function of the PC.<\/div>\n<\/dd>\n<\/dl>\n<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">2<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">VERIFY RELATED REPAIR INFORMATION OR SERVICE INFORMATION AVAILABILITY<\/div>\n<div class=\"list\">\u2022 Verify related Service Bulletins, on-line repair information, or Service Information availability.<\/div>\n<div class=\"list\">\u2022 Is any related Information available?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Perform repair or diagnosis according to the available information.<\/div>\n<div class=\"list\">\u2022 If the vehicle is not repaired, go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">3<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT A\/F SENSOR CONNECTOR FOR MALFUNCTION<\/div>\n<div class=\"list\">\u2022 Inspect the applicable connector and terminal. (See <a href=\"SM2337320\">CONNECTOR INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Are the connector and terminal normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location and perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">4<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT F8 15 A FUSE<\/div>\n<div class=\"list\">\u2022 Remove the F8 15 A fuse.<\/div>\n<div class=\"list\">\u2022 Inspect the F8 15 A fuse.<\/div>\n<div class=\"list\">\u2022 Is the fuse normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Reinstall the F8 15 A fuse, then go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Replace the F8 15 A fuse and perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">5<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT A\/F SENSOR HEATER POWER SUPPLY CIRCUIT FOR SHORT TO GROUND<\/div>\n<div class=\"list\">\u2022 Inspect the applicable circuit for a short to ground. (See <a href=\"SM2337319\">CIRCUIT INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the circuit normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location and perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">6<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT A\/F SENSOR HEATER POWER SUPPLY CIRCUIT FOR OPEN CIRCUIT<\/div>\n<div class=\"list\">\u2022 Inspect the applicable circuit for open circuit. (See <a href=\"SM2337319\">CIRCUIT INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the circuit normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location and perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">7<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT A\/F SENSOR HEATER FOR MALFUNCTION<\/div>\n<div class=\"list\">\u2022 Inspect the applicable part. (See <a href=\"SM2565926\">AIR FUEL RATIO (A\/F) SENSOR INSPECTION [SKYACTIV-G (WITH CYLINDER DEACTIVATION (US))]<\/a>.) (See <a href=\"SM2565880\">AIR FUEL RATIO (A\/F) SENSOR INSPECTION [SKYACTIV-G (WITHOUT CYLINDER DEACTIVATION (US))]<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the part normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location and perform the repair completion verification.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2565927\">AIR FUEL RATIO (A\/F) SENSOR REMOVAL\/INSTALLATION [SKYACTIV-G (WITH CYLINDER DEACTIVATION (US))]<\/a>.)<\/div>\n<div class=\"tbody\">(See <a href=\"SM2565881\">AIR FUEL RATIO (A\/F) SENSOR REMOVAL\/INSTALLATION [SKYACTIV-G (WITHOUT CYLINDER DEACTIVATION (US))]<\/a>.)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">8<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT PCM CONNECTOR FOR MALFUNCTION<\/div>\n<div class=\"list\">\u2022 Inspect the applicable connector and terminal. (See <a href=\"SM2337320\">CONNECTOR INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Are the connector and terminal normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location and perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">9<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT A\/F SENSOR HEATER CONTROL CIRCUIT FOR OPEN CIRCUIT<\/div>\n<div class=\"list\">\u2022 Inspect the applicable circuit for open circuit. (See <a href=\"SM2337319\">CIRCUIT INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the circuit normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location and perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">10<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT A\/F SENSOR HEATER CONTROL CIRCUIT FOR SHORT TO GROUND<\/div>\n<div class=\"list\">\u2022 Inspect the applicable circuit for a short to ground. (See <a href=\"SM2337319\">CIRCUIT INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the circuit normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location and perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">Repair completion verification 1<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">VERIFY THAT VEHICLE IS REPAIRED<\/div>\n<div class=\"list\">\u2022 Install\/connect the part removed\/disconnected during the troubleshooting procedure.<\/div>\n<div class=\"list\">\u2022 Clear the DTC recorded in the memory. (See <a href=\"SM2337316\">CLEARING DTC<\/a>.)<\/div>\n<div class=\"list\">\u2022 Replicate the vehicle conditions at the time the DTC was detected using the following procedure.<\/div>\n<dl>\n<dd class=\"list\">\n<div class=\"list\">\u2015 Perform the KOER self test. (See <a href=\"SM2337315\">DTC INSPECTION<\/a>.)<\/div>\n<\/dd>\n<\/dl>\n<div class=\"list\">\u2022 Perform the DTC inspection for the PCM. (See <a href=\"SM2337315\">DTC INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the same Pending DTC present?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Refer to the controller area network (CAN) malfunction diagnosis flow to inspect for a CAN communication error.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2566441\">CONTROLLER AREA NETWORK (CAN) MALFUNCTION DIAGNOSIS FLOW [(US)]<\/a>.)<\/div>\n<div class=\"tbody\">If the CAN communication is normal, perform the diagnosis from Step 1.<\/div>\n<div class=\"list\">\u2022 If the malfunction recurs, replace the PCM, then go to the next step. (See <a href=\"SM2565911\">PCM REMOVAL\/INSTALLATION [SKYACTIV-G (WITH CYLINDER DEACTIVATION (US))]<\/a>.) (See <a href=\"SM2565865\">PCM REMOVAL\/INSTALLATION [SKYACTIV-G (WITHOUT CYLINDER DEACTIVATION (US))]<\/a>.)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">Repair completion verification 2<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">VERIFY IF OTHER DTCs DISPLAYED<\/div>\n<div class=\"list\">\u2022 Perform the DTC inspection. (See <a href=\"SM2337315\">DTC INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Are any other DTCs displayed?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair the malfunctioning location according to the applicable DTC troubleshooting.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">DTC troubleshooting completed.<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"ATTACHMENTS\"><\/div>\n<div class=\"attr VTOC_FILENAME content c2\"><!--\n                        am3zz0102t4w0000992 --><\/div>\n<div class=\"attr SIE_ID content c2\"><!--\n                        id0102t4933800.ent --><\/div>\n<p><!--\n*****************************\nERROR: Schema not found. TYPE=META REFERENCEKEY=SERVICE_MANUALS ROOT=null\n*****************************\n--><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>DTC P0053:00 [PCM (SKYACTIV-G)] SM2334590 id0102t4933800 Outline System malfunction location A\/F sensor heater resistance Detection condition \u2022 When the PCM controls the A\/F sensor heater, the A\/F sensor element resistance input to the PCM is the specified value or more. Fail-safe \u2022 Stops fuel feedback control Possible cause \u2022 A\/F sensor connector or terminals malfunction \u2022 F8 15 A fuse malfunction \u2022 Short to ground in A\/F sensor heater power supply circuit \u2022 Open circuit [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-8973","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/8973","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/comments?post=8973"}],"version-history":[{"count":0,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/8973\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/media?parent=8973"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}