{"id":8812,"date":"2022-03-10T20:30:42","date_gmt":"2022-03-10T20:30:42","guid":{"rendered":"https:\/\/www.hexorcism.com\/19BP\/sm2334350\/"},"modified":"2022-03-10T20:30:42","modified_gmt":"2022-03-10T20:30:42","slug":"sm2334350","status":"publish","type":"page","link":"https:\/\/www.hexorcism.com\/19BP\/sm2334350\/","title":{"rendered":"REPAIR-USE CONNECTOR REPLACEMENT PROCEDURE"},"content":{"rendered":"<div class=\"detailsTabContent\">\n<h3 class=\"c1\">REPAIR-USE CONNECTOR REPLACEMENT PROCEDURE<\/h3>\n<\/div>\n<p>SM2334350<\/p>\n<div class=\"node SERVICE_MANUALS\"><\/p>\n<div class=\"textleft\">\n<div class=\"attr CONTENT content c2\">\n<hr \/>\n<p class=\"servinfo-title-id\" align=\"right\">id000000003000<\/p>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id00000000300001\" id=\"id00000000300001\"><\/a><\/p>\n<p class=\"servinfosub-title\">Wire Harness Cutting On Vehicle Side<\/p>\n<p class=\"list\">1.If tubing or tape is used to protect the connector wiring harness, cut into it being careful not cut or damage the wiring, and expose <span>approx. 200 mm {7.84 in}<\/span> of the wiring from the connector.<\/p>\n<p class=\"list\">\n<table class=\"figure-flame table-flame\">\n<tbody>\n<tr>\n<td width=\"10mm\"><\/td>\n<td>\n<table class=\"figure-float table-flame\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am6xuw00006203.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am6xuw00006203<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"list\">2.Cut the wiring harness once at the position near the connector so as to leave a long length of wiring harness on the vehicle side, align the length with the repair-use connector wiring harness, and then re-cut at the wiring harness on the vehicle side or the repair-use connector wiring harness at the appropriate position.<\/p>\n<p class=\"list\">\n<table class=\"figure-flame table-flame\">\n<tbody>\n<tr>\n<td width=\"10mm\"><\/td>\n<td>\n<table class=\"figure-float table-flame\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/acmzzc00000415.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">acmzzc00000415<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<dl>\n<dd>\n<div class=\"attention2-label\">Caution<\/div>\n<\/dd>\n<dd>\n<div class=\"attention2\">\n<div class=\"list\">\u2022 Cut longer in consideration of the amount of wiring harness length which will be soldered.<\/div>\n<div class=\"list\">\u2022 If the cut wiring harness length is different than the repair-use wiring harness length, the following problems may occur.<\/div>\n<dl>\n<dd class=\"list\">\n<div class=\"list\">\u2015 If too short: Tension will be applied to the terminal, splice or connector resulting in an open circuit.<\/div>\n<div class=\"list\">\u2015 If too long: A short may occur due to pinching and wear of the extra length of wiring harness near the connector.<\/div>\n<\/dd>\n<\/dl>\n<\/div>\n<\/dd>\n<\/dl>\n<dl>\n<dd>\n<div class=\"attention3-label\">Note<\/div>\n<\/dd>\n<dd>\n<div class=\"attention3 list\">\u2022 If several wiring harnesses are connected to the same connector, stagger the cut positions so that the repair positions do not overlap as shown in the figure to prevent thickening of the wiring harness after repair.<\/p>\n<table class=\"figure-flame table-flame\">\n<tbody>\n<tr>\n<td width=\"10mm\"><\/td>\n<td>\n<table class=\"figure-float table-flame\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am6zzw00011195.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am6zzw00011195<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/dd>\n<\/dl>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id00000000300002\" id=\"id00000000300002\"><\/a><\/p>\n<p class=\"servinfosub-title\">Cut Off the Insulation from the Wiring Harness on the Vehicle Side and the Repair-use Connector Wiring Harness<\/p>\n<p class=\"list\">1.Strip off the insulation from the ends of the vehicle wiring harness and the repair-use connector wiring harness.<\/p>\n<p class=\"list\">\n<table class=\"figure-flame table-flame\">\n<tbody>\n<tr>\n<td width=\"10mm\"><\/td>\n<td>\n<table class=\"figure-float table-flame\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/ac9uuw00009709.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">ac9uuw00009709<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"spec\">\n<dl>\n<dd>\n<div class=\"list\">\u2022 For soldering repairs: 10\u201420 mm {0.40\u20140.78 in}<\/div>\n<div class=\"list\">\u2022 For repairs using crimp terminal: 6\u20147 mm {0.24\u20140.27 in}<\/div>\n<\/dd>\n<\/dl>\n<\/div>\n<dl>\n<dd>\n<div class=\"attention3-label\">Note<\/div>\n<\/dd>\n<dd>\n<div class=\"attention3 list\">\u2022 If the wiring harness to be repaired is thick, core twisting can be facilitated by lengthening the amount of insulation cut.<\/div>\n<\/dd>\n<\/dl>\n<dl>\n<dd>\n<div class=\"attention2-label\">Caution<\/div>\n<\/dd>\n<dd>\n<div class=\"attention2\">\n<div class=\"list\">\u2022 Do not damage or cut the cores of the wiring harnesses. After finishing the work, inspect the wiring harnesses for damage or cutting of the cores, and re-do the work if necessary.<\/div>\n<table class=\"figure-flame table-flame\">\n<tbody>\n<tr>\n<td width=\"10mm\"><\/td>\n<td>\n<table class=\"figure-float table-flame\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/amxzzw00003884.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">amxzzw00003884<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/dd>\n<\/dl>\n<p class=\"list\">2.Depending on the thickness of the wiring harness which is being repaired, select an appropriate heat shrinkable tube, and before twisting the cores together, pass them through the heat shrinkable tube.<\/p>\n<p class=\"list\">\n<table class=\"figure-flame table-flame\">\n<tbody>\n<tr>\n<td width=\"10mm\"><\/td>\n<td>\n<table class=\"figure-float table-flame\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am6xuw00006207.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am6xuw00006207<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p clear=\"all\">\n<table class=\"table-flame\" border=\"1\">\n<thead>\n<tr>\n<th id=\"\" align=\"left\" rowspan=\"2\">\n<p class=\"thead\">\n<\/th>\n<th id=\"\" align=\"center\" colspan=\"2\">\n<p class=\"thead\">Heat shrinkable tube<\/p>\n<\/th>\n<th id=\"\" align=\"center\" rowspan=\"2\">\n<p class=\"thead\">Wiring size (exterior diameter)<\/p>\n<\/th>\n<\/tr>\n<tr>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Before shrinking<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">After shrinking<\/p>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Small<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">4 mm {0.2 in}<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">1 mm {0.04 in}<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u03c62 mm {0.08 in} or less<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Large<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">8 mm {0.3 in}<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">2 mm {0.08 in}<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u03c62 mm {0.08 in} or more<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<dl>\n<dd>\n<div class=\"attention3-label\">Note<\/div>\n<\/dd>\n<dd>\n<div class=\"attention3 list\">\u2022 If the exposed area of the core where the solder is applied is a shorter length of approx. <span>10 mm {0.39 in}<\/span>, half the length ( <span>25 mm {0.98 in}<\/span>) of the heat-shrinkable tubing can be cut and used because the total length of the heat-shrinkable tubing is <span>50 mm {2.0 in}<\/span>.<\/div>\n<\/dd>\n<\/dl>\n<\/div>\n<div class=\"ATTACHMENTS\"><\/div>\n<div class=\"attr VTOC_FILENAME content c2\"><!--\n                        atsvu000000w0000009 --><\/div>\n<div class=\"attr SIE_ID content c2\"><!--\n                        id000000003000.ent --><\/div>\n<p><!--\n*****************************\nERROR: Schema not found. TYPE=META REFERENCEKEY=SERVICE_MANUALS ROOT=null\n*****************************\n--><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>REPAIR-USE CONNECTOR REPLACEMENT PROCEDURE SM2334350 id000000003000 Wire Harness Cutting On Vehicle Side 1.If tubing or tape is used to protect the connector wiring harness, cut into it being careful not cut or damage the wiring, and expose approx. 200 mm {7.84 in} of the wiring from the connector. am6xuw00006203 2.Cut the wiring harness once at the position near the connector so as to leave a long length of wiring harness on the vehicle side, align [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-8812","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/8812","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/comments?post=8812"}],"version-history":[{"count":0,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/8812\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/media?parent=8812"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}