{"id":8567,"date":"2022-03-10T20:30:40","date_gmt":"2022-03-10T20:30:40","guid":{"rendered":"https:\/\/www.hexorcism.com\/19BP\/sm2333643\/"},"modified":"2022-03-10T20:30:40","modified_gmt":"2022-03-10T20:30:40","slug":"sm2333643","status":"publish","type":"page","link":"https:\/\/www.hexorcism.com\/19BP\/sm2333643\/","title":{"rendered":"FRONT PILLAR REMOVAL [PANEL REPLACEMENT]"},"content":{"rendered":"<div class=\"detailsTabContent\">\n<h3 class=\"c1\">FRONT PILLAR REMOVAL [PANEL REPLACEMENT]<\/h3>\n<\/div>\n<p>SM2333643<\/p>\n<div class=\"node SERVICE_MANUALS\"><\/p>\n<div class=\"textleft\">\n<div class=\"attr CONTENT content c2\">\n<hr \/>\n<p class=\"servinfo-title-id\" align=\"right\">id098008744700<\/p>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id09800874470001\" id=\"id09800874470001\"><\/a><\/p>\n<p class=\"servinfosub-title\">Symbol Mark<\/p>\n<table class=\"figure-flame-non table-flame\">\n<tbody>\n<tr>\n<td>\n<table class=\"figure-non-float table-flame\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am6zzb00000379.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am6zzb00000379<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id09800874470002\" id=\"id09800874470002\"><\/a><\/p>\n<p class=\"servinfosub-title\">Removal Procedure<\/p>\n<dl>\n<dd>\n<div class=\"attention2-label\">Caution<\/div>\n<\/dd>\n<dd>\n<div class=\"attention2\">\n<div class=\"list\">\u2022 To prevent injury, remove the curtain air bag module before performing the work.<\/div>\n<p class=\"figure-title\">4SD<\/p>\n<table class=\"figure-flame-non table-flame\">\n<tbody>\n<tr>\n<td>\n<table class=\"figure-non-float table-flame\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzb00000404.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3zzb00000404<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"figure-title\">5HB<\/p>\n<table class=\"figure-flame-non table-flame\">\n<tbody>\n<tr>\n<td>\n<table class=\"figure-non-float table-flame\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzb00000405.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3zzb00000405<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/dd>\n<\/dl>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id09800874470003\" id=\"id09800874470003\"><\/a><\/p>\n<p class=\"servinfosub-title\">4SD<\/p>\n<p class=\"list\">1.Drill the spot welds in the 80 locations in area A shown in the figure.<\/p>\n<p class=\"list\">\n<table class=\"figure-flame-non table-flame\">\n<tbody>\n<tr>\n<td>\n<table class=\"figure-non-float table-flame\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzb00000347.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3zzb00000347<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"list\">2.Remove the roof panel.<\/p>\n<p class=\"list\">\n<dl>\n<dd>\n<div class=\"attention2-label\">Caution<\/div>\n<\/dd>\n<dd>\n<div class=\"attention2\">\n<div class=\"list\">\u2022 If cutting work is done using flame, a fire could occur because insulators are inserted in the locations shown in the figure. When performing the cutting work near the insulator insert areas, avoid using flame and use an air saw or drill.<\/div>\n<table class=\"figure-flame-non table-flame\">\n<tbody>\n<tr>\n<td>\n<table class=\"figure-non-float table-flame\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzb00000348.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3zzb00000348<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/dd>\n<\/dl>\n<p class=\"list\">3.Rough cut the 2 locations in area B shown in the figure.<\/p>\n<p class=\"list\">\n<table class=\"figure-flame-non table-flame\">\n<tbody>\n<tr>\n<td>\n<table class=\"figure-non-float table-flame\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzb00000349.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3zzb00000349<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"list\">4.Drill the spot welds in the 97 locations in area C shown in the figure.<\/p>\n<p class=\"list\">\n<table class=\"figure-flame-non table-flame\">\n<tbody>\n<tr>\n<td>\n<table class=\"figure-non-float table-flame\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzb00000350.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3zzb00000350<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"list\">5.Remove the cabin side frame (outer) (front pillar (outer)).<\/p>\n<p class=\"list\">\n<dl>\n<dd>\n<div class=\"attention2-label\">Caution<\/div>\n<\/dd>\n<dd>\n<div class=\"attention2 list\">\u2022 If cutting work is done using flame, a fire could occur because insulators are inserted in the locations shown in the figure. When performing the cutting work near the insulator insert areas, avoid using flame and use an air saw or drill.<\/div>\n<\/dd>\n<\/dl>\n<table class=\"figure-flame-non table-flame\">\n<tbody>\n<tr>\n<td>\n<table class=\"figure-non-float table-flame\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzb00000351.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3zzb00000351<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"list\">6.Drill the spot welds in the 20 locations in area D shown in the figure.<\/p>\n<p class=\"list\">\n<dl>\n<dd>\n<div class=\"attention3-label\">Note<\/div>\n<\/dd>\n<dd>\n<div class=\"attention3 list\">\u2022 When drilling the spot welds in the 20 locations in area D shown in the figure, do not drill through-holes in consideration of the workability when installing.<\/div>\n<\/dd>\n<\/dl>\n<p class=\"list\">7.Drill the spot welds in the 7 locations in area E shown in the figure.<\/p>\n<p class=\"list\">\n<table class=\"figure-flame-non table-flame\">\n<tbody>\n<tr>\n<td>\n<table class=\"figure-non-float table-flame\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzb00000352.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3zzb00000352<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"list\">8.Remove the hinge reinforcement and the front pillar reinforcement (upper) at the same time.<\/p>\n<p class=\"list\">\n<p class=\"list\">9.Drill the spot welds in the 14 locations in area F shown in the figure from the interior.<\/p>\n<p class=\"list\">\n<dl>\n<dd>\n<div class=\"attention3-label\">Note<\/div>\n<\/dd>\n<dd>\n<div class=\"attention3 list\">\u2022 When drilling the spot welds in the 14 locations in area F shown in the figure, do not drill through-holes in consideration of the workability when installing.<\/div>\n<\/dd>\n<\/dl>\n<table class=\"figure-flame-non table-flame\">\n<tbody>\n<tr>\n<td>\n<table class=\"figure-non-float table-flame\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzb00000353.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3zzb00000353<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"list\">10.Remove the front pillar upper reinforcement.<\/p>\n<p class=\"list\">\n<p class=\"list\">11.Drill the spot welds in the 3 locations in area G shown in the figure from the interior.<\/p>\n<p class=\"list\">\n<table class=\"figure-flame-non table-flame\">\n<tbody>\n<tr>\n<td>\n<table class=\"figure-non-float table-flame\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzb00000354.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3zzb00000354<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"list\">12.Remove the front pillar (inner).<\/p>\n<p class=\"list\">\n<p class=\"list\">13.Drill the spot welds in the 27 locations in area H shown in the figure.<\/p>\n<p class=\"list\">\n<table class=\"figure-flame-non table-flame\">\n<tbody>\n<tr>\n<td>\n<table class=\"figure-non-float table-flame\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzb00000355.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3zzb00000355<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"list\">14.Remove the hinge pillar (inner).<\/p>\n<p class=\"list\">\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id09800874470004\" id=\"id09800874470004\"><\/a><\/p>\n<p class=\"servinfosub-title\">5HB<\/p>\n<p class=\"list\">1.Drill the spot welds in the 94 locations in area A shown in the figure.<\/p>\n<p class=\"list\">\n<p class=\"list\">2.Drill the spot welds in the 14 locations in area B shown in the figure.<\/p>\n<p class=\"list\">\n<table class=\"figure-flame-non table-flame\">\n<tbody>\n<tr>\n<td>\n<table class=\"figure-non-float table-flame\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzb00000356.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3zzb00000356<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"list\">3.Remove the roof panel.<\/p>\n<p class=\"list\">\n<dl>\n<dd>\n<div class=\"attention2-label\">Caution<\/div>\n<\/dd>\n<dd>\n<div class=\"attention2\">\n<div class=\"list\">\u2022 If cutting work is done using flame, a fire could occur because insulators are inserted in the locations shown in the figure. When performing the cutting work near the insulator insert areas, avoid using flame and use an air saw or drill.<\/div>\n<table class=\"figure-flame-non table-flame\">\n<tbody>\n<tr>\n<td>\n<table class=\"figure-non-float table-flame\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzb00000357.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3zzb00000357<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/dd>\n<\/dl>\n<p class=\"list\">4.Rough cut the 2 locations in area C shown in the figure.<\/p>\n<p class=\"list\">\n<table class=\"figure-flame-non table-flame\">\n<tbody>\n<tr>\n<td>\n<table class=\"figure-non-float table-flame\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzb00000358.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3zzb00000358<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"list\">5.Drill the spot welds in the 97 locations in area D shown in the figure.<\/p>\n<p class=\"list\">\n<table class=\"figure-flame-non table-flame\">\n<tbody>\n<tr>\n<td>\n<table class=\"figure-non-float table-flame\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzb00000359.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3zzb00000359<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"list\">6.Remove the cabin side frame (outer) (front pillar (outer)).<\/p>\n<p class=\"list\">\n<dl>\n<dd>\n<div class=\"attention2-label\">Caution<\/div>\n<\/dd>\n<dd>\n<div class=\"attention2 list\">\u2022 If cutting work is done using flame, a fire could occur because insulators are inserted in the locations shown in the figure. When performing the cutting work near the insulator insert areas, avoid using flame and use an air saw or drill.<\/div>\n<\/dd>\n<\/dl>\n<table class=\"figure-flame-non table-flame\">\n<tbody>\n<tr>\n<td>\n<table class=\"figure-non-float table-flame\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzb00000360.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3zzb00000360<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"list\">7.Drill the spot welds in the 20 locations in area E shown in the figure.<\/p>\n<p class=\"list\">\n<dl>\n<dd>\n<div class=\"attention3-label\">Note<\/div>\n<\/dd>\n<dd>\n<div class=\"attention3 list\">\u2022 When drilling the spot welds in the 20 locations in area E shown in the figure, do not drill through-holes in consideration of the workability when installing.<\/div>\n<\/dd>\n<\/dl>\n<p class=\"list\">8.Drill the spot welds in the 7 locations in area F shown in the figure.<\/p>\n<p class=\"list\">\n<table class=\"figure-flame-non table-flame\">\n<tbody>\n<tr>\n<td>\n<table class=\"figure-non-float table-flame\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzb00000365.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3zzb00000365<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"list\">9.Remove the hinge reinforcement and the front pillar reinforcement (upper) at the same time.<\/p>\n<p class=\"list\">\n<p class=\"list\">10.Drill the spot welds in the 14 locations in area G shown in the figure from the interior.<\/p>\n<p class=\"list\">\n<dl>\n<dd>\n<div class=\"attention3-label\">Note<\/div>\n<\/dd>\n<dd>\n<div class=\"attention3 list\">\u2022 When drilling the spot welds in the 14 locations in area G shown in the figure, do not drill through-holes in consideration of the workability when installing.<\/div>\n<\/dd>\n<\/dl>\n<table class=\"figure-flame-non table-flame\">\n<tbody>\n<tr>\n<td>\n<table class=\"figure-non-float table-flame\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzb00000366.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3zzb00000366<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"list\">11.Remove the front pillar upper reinforcement.<\/p>\n<p class=\"list\">\n<p class=\"list\">12.Drill the spot welds in the 3 locations in area H shown in the figure from the interior.<\/p>\n<p class=\"list\">\n<table class=\"figure-flame-non table-flame\">\n<tbody>\n<tr>\n<td>\n<table class=\"figure-non-float table-flame\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzb00000367.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3zzb00000367<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"list\">13.Remove the front pillar (inner).<\/p>\n<p class=\"list\">\n<p class=\"list\">14.Drill the spot welds in the 27 locations in area I shown in the figure.<\/p>\n<p class=\"list\">\n<table class=\"figure-flame-non table-flame\">\n<tbody>\n<tr>\n<td>\n<table class=\"figure-non-float table-flame\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzb00000368.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3zzb00000368<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"list\">15.Remove the hinge pillar (inner).<\/p>\n<p class=\"list\">\n<\/div>\n<div class=\"ATTACHMENTS\"><\/div>\n<div class=\"attr VTOC_FILENAME content c2\"><!--\n                        am3zz098008b0000067 --><\/div>\n<div class=\"attr SIE_ID content c2\"><!--\n                        id098008744700.ent --><\/div>\n<p><!--\n*****************************\nERROR: Schema not found. TYPE=META REFERENCEKEY=SERVICE_MANUALS ROOT=null\n*****************************\n--><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>FRONT PILLAR REMOVAL [PANEL REPLACEMENT] SM2333643 id098008744700 Symbol Mark am6zzb00000379 Removal Procedure Caution \u2022 To prevent injury, remove the curtain air bag module before performing the work. 4SD am3zzb00000404 5HB am3zzb00000405 4SD 1.Drill the spot welds in the 80 locations in area A shown in the figure. am3zzb00000347 2.Remove the roof panel. Caution \u2022 If cutting work is done using flame, a fire could occur because insulators are inserted in the locations shown in the [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-8567","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/8567","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/comments?post=8567"}],"version-history":[{"count":0,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/8567\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/media?parent=8567"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}