{"id":10397,"date":"2022-03-10T20:30:55","date_gmt":"2022-03-10T20:30:55","guid":{"rendered":"https:\/\/www.hexorcism.com\/19BP\/sm2566295\/"},"modified":"2022-03-10T20:30:55","modified_gmt":"2022-03-10T20:30:55","slug":"sm2566295","status":"publish","type":"page","link":"https:\/\/www.hexorcism.com\/19BP\/sm2566295\/","title":{"rendered":"REFRIGERANT PRESSURE SENSOR REMOVAL\/INSTALLATION [MANUAL AIR CONDITIONER (US)]"},"content":{"rendered":"<div class=\"detailsTabContent\">\n<h3 class=\"c1\">REFRIGERANT PRESSURE SENSOR REMOVAL\/INSTALLATION [MANUAL AIR CONDITIONER (US)]<\/h3>\n<\/div>\n<p>SM2566295<\/p>\n<div class=\"node SERVICE_MANUALS\"><\/p>\n<div class=\"textleft\">\n<div class=\"attr CONTENT content c2\">\n<hr \/>\n<p class=\"servinfo-title-id\" align=\"right\">id0740a28173y3<\/p>\n<p class=\"table-title\">Replacement Part<\/p>\n<table class=\"table-flame\" border=\"1\">\n<tbody>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">O-ring<\/div>\n<div class=\"tbody\"><\/div>\n<div class=\"tbody\">Quantity: 1<\/div>\n<div class=\"tbody\"><\/div>\n<div class=\"tbody\">Location of use: Refrigerant pressure sensor<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id0740a28173y301\" id=\"id0740a28173y301\"><\/a><\/p>\n<p class=\"servinfosub-title\">Refrigerant Pressure Sensor No.1<\/p>\n<dl>\n<dd>\n<div class=\"attention3-label\">Note<\/div>\n<\/dd>\n<dd>\n<div class=\"attention3 list\">\u2022 The refrigerant pressure sensor No.1 is located in the cooler pipe.<\/div>\n<\/dd>\n<\/dl>\n<p class=\"list\">1.Disconnect the negative battery terminal. (See <a href=\"SM2565818\">NEGATIVE BATTERY TERMINAL DISCONNECTION\/CONNECTION [(US)]<\/a>.)<\/p>\n<p class=\"list\">\n<p class=\"list\">2.Discharge the refrigerant. (See <a href=\"SM2566250\">REFRIGERANT RECOVERY<\/a>.) (See <a href=\"SM2566248\">REFRIGERANT CHARGING [(US)]<\/a>.)<\/p>\n<p class=\"list\">\n<p class=\"list\">3.Remove the plug hole plate (See <a href=\"SM2565613\">PLUG HOLE PLATE REMOVAL\/INSTALLATION [SKYACTIV-G (WITHOUT CYLINDER DEACTIVATION (US))]<\/a>.) (See <a href=\"SM2565639\">PLUG HOLE PLATE REMOVAL\/INSTALLATION [SKYACTIV-G (WITH CYLINDER DEACTIVATION (US))]<\/a>.)<\/p>\n<p class=\"list\">\n<p class=\"list\">4.Remove the cooler pipe. (See <a href=\"SM2335723\">REFRIGERANT LINE REMOVAL\/INSTALLATION [SKYACTIV-G 2.0, SKYACTIV-G 2.5]<\/a>.)<\/p>\n<p class=\"list\">\n<p class=\"list\">5.Loosen the refrigerant pressure sensor using two spanners.<\/p>\n<p class=\"list\">\n<table class=\"figure-flame\">\n<tbody>\n<tr>\n<td width=\"10mm\"><\/td>\n<td>\n<table class=\"figure-float\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/ac5wzw00008860.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">ac5wzw00008860<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"list\">6.Remove the refrigerant pressure sensor.<\/p>\n<p class=\"list\">\n<table class=\"figure-flame\">\n<tbody>\n<tr>\n<td width=\"10mm\"><\/td>\n<td>\n<table class=\"figure-float\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzw00021430.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3zzw00021430<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<dl>\n<dd>\n<div class=\"attention2-label\">Caution<\/div>\n<\/dd>\n<dd>\n<div class=\"attention2 list\">\u2022 If moisture or foreign material enters the refrigeration cycle, cooling ability will be lowered and abnormal noise will occur. Always immediately plug all open fittings after removing any refrigeration cycle parts to keep moisture or foreign material out of the cycle.<\/div>\n<\/dd>\n<\/dl>\n<p class=\"list\">7.Install in the reverse order of removal. (See <a href=\"#id0740a28173y302\">Refrigerant pressure sensor installation note<\/a>.)<\/p>\n<p class=\"list\">\n<p class=\"list\">8.Perform the refrigerant system performance test. (See <a href=\"SM2566247\">REFRIGERANT SYSTEM PERFORMANCE TEST [(US)]<\/a>.)<\/p>\n<p class=\"list\">\n<p><br clear=\"all\" \/><\/p>\n<p><a name=\"id0740a28173y302\" id=\"id0740a28173y302\"><\/a><\/p>\n<p class=\"topic-title\">Refrigerant pressure sensor installation note<\/p>\n<p class=\"list\">1.Apply compressor oil to the O-rings and connect the joints.<\/p>\n<p class=\"list\">\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id0740a28173y303\" id=\"id0740a28173y303\"><\/a><\/p>\n<p class=\"servinfosub-title\">Refrigerant Pressure Sensor No.2<\/p>\n<dl>\n<dd>\n<div class=\"attention3-label\">Note<\/div>\n<\/dd>\n<dd>\n<div class=\"attention3 list\">\u2022 The refrigerant pressure sensor No.2 is located in the cooler hose (HI).<\/div>\n<\/dd>\n<\/dl>\n<p class=\"list\">1.Disconnect the negative battery terminal. (See <a href=\"SM2565818\">NEGATIVE BATTERY TERMINAL DISCONNECTION\/CONNECTION [(US)]<\/a>.)<\/p>\n<p class=\"list\">\n<p class=\"list\">2.Discharge the refrigerant. (See <a href=\"SM2566250\">REFRIGERANT RECOVERY<\/a>.) (See <a href=\"SM2566248\">REFRIGERANT CHARGING [(US)]<\/a>.)<\/p>\n<p class=\"list\">\n<p class=\"list\">3.Remove the plug hole plate (See <a href=\"SM2565613\">PLUG HOLE PLATE REMOVAL\/INSTALLATION [SKYACTIV-G (WITHOUT CYLINDER DEACTIVATION (US))]<\/a>.) (See <a href=\"SM2565639\">PLUG HOLE PLATE REMOVAL\/INSTALLATION [SKYACTIV-G (WITH CYLINDER DEACTIVATION (US))]<\/a>.)<\/p>\n<p class=\"list\">\n<p class=\"list\">4.Remove the cooler hose (HI). (See <a href=\"SM2335723\">REFRIGERANT LINE REMOVAL\/INSTALLATION [SKYACTIV-G 2.0, SKYACTIV-G 2.5]<\/a>.)<\/p>\n<p class=\"list\">\n<p class=\"list\">5.Loosen the refrigerant pressure sensor using two spanners.<\/p>\n<p class=\"list\">\n<table class=\"figure-flame\">\n<tbody>\n<tr>\n<td width=\"10mm\"><\/td>\n<td>\n<table class=\"figure-float\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/ac5wzw00008860.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">ac5wzw00008860<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"list\">6.Remove the refrigerant pressure sensor.<\/p>\n<p class=\"list\">\n<table class=\"figure-flame\">\n<tbody>\n<tr>\n<td width=\"10mm\"><\/td>\n<td>\n<table class=\"figure-float\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzw00021429.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3zzw00021429<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<dl>\n<dd>\n<div class=\"attention2-label\">Caution<\/div>\n<\/dd>\n<dd>\n<div class=\"attention2 list\">\u2022 If moisture or foreign material enters the refrigeration cycle, cooling ability will be lowered and abnormal noise will occur. Always immediately plug all open fittings after removing any refrigeration cycle parts to keep moisture or foreign material out of the cycle.<\/div>\n<\/dd>\n<\/dl>\n<p class=\"list\">7.Install in the reverse order of removal. (See <a href=\"#id0740a28173y304\">Refrigerant pressure sensor installation note<\/a>.)<\/p>\n<p class=\"list\">\n<p class=\"list\">8.Perform the refrigerant system performance test. (See <a href=\"SM2566247\">REFRIGERANT SYSTEM PERFORMANCE TEST [(US)]<\/a>.)<\/p>\n<p class=\"list\">\n<p><br clear=\"all\" \/><\/p>\n<p><a name=\"id0740a28173y304\" id=\"id0740a28173y304\"><\/a><\/p>\n<p class=\"topic-title\">Refrigerant pressure sensor installation note<\/p>\n<p class=\"list\">1.Apply compressor oil to the O-rings and connect the joints.<\/p>\n<p class=\"list\">\n<\/div>\n<div class=\"ATTACHMENTS\"><\/div>\n<div class=\"attr VTOC_FILENAME content c2\"><!--\n                        am3zz0740a2w0000075 --><\/div>\n<div class=\"attr SIE_ID content c2\"><!--\n                        id0740a28173y3.ent --><\/div>\n<p><!--\n*****************************\nERROR: Schema not found. TYPE=META REFERENCEKEY=SERVICE_MANUALS ROOT=null\n*****************************\n--><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>REFRIGERANT PRESSURE SENSOR REMOVAL\/INSTALLATION [MANUAL AIR CONDITIONER (US)] SM2566295 id0740a28173y3 Replacement Part O-ring Quantity: 1 Location of use: Refrigerant pressure sensor Refrigerant Pressure Sensor No.1 Note \u2022 The refrigerant pressure sensor No.1 is located in the cooler pipe. 1.Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION\/CONNECTION [(US)].) 2.Discharge the refrigerant. (See REFRIGERANT RECOVERY.) (See REFRIGERANT CHARGING [(US)].) 3.Remove the plug hole plate (See PLUG HOLE PLATE REMOVAL\/INSTALLATION [SKYACTIV-G (WITHOUT CYLINDER DEACTIVATION (US))].) (See [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-10397","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/10397","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/comments?post=10397"}],"version-history":[{"count":0,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/10397\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/media?parent=10397"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}