{"id":10385,"date":"2022-03-10T20:30:55","date_gmt":"2022-03-10T20:30:55","guid":{"rendered":"https:\/\/www.hexorcism.com\/19BP\/sm2566283\/"},"modified":"2022-03-10T20:30:55","modified_gmt":"2022-03-10T20:30:55","slug":"sm2566283","status":"publish","type":"page","link":"https:\/\/www.hexorcism.com\/19BP\/sm2566283\/","title":{"rendered":"AIRFLOW MODE ACTUATOR INSPECTION [MANUAL AIR CONDITIONER]"},"content":{"rendered":"<div class=\"detailsTabContent\">\n<h3 class=\"c1\">AIRFLOW MODE ACTUATOR INSPECTION [MANUAL AIR CONDITIONER]<\/h3>\n<\/div>\n<p>SM2566283<\/p>\n<div class=\"node SERVICE_MANUALS\"><\/p>\n<div class=\"textleft\">\n<div class=\"attr CONTENT content c2\">\n<hr \/>\n<p class=\"servinfo-title-id\" align=\"right\">id0740a2801700<\/p>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id0740a280170001\" id=\"id0740a280170001\"><\/a><\/p>\n<p class=\"servinfosub-title\">Actuator inspection<\/p>\n<p class=\"list\">1.Disconnect the negative battery terminal. (See <a href=\"SM2565818\">NEGATIVE BATTERY TERMINAL DISCONNECTION\/CONNECTION [(US)]<\/a>.)<\/p>\n<p class=\"list\">\n<p class=\"list\">2.Remove the airflow mode actuator. (See <a href=\"SM2566292\">AIRFLOW MODE ACTUATOR REMOVAL [MANUAL AIR CONDITIONER (US)]<\/a>.)(See <a href=\"SM2566293\">AIRFLOW MODE ACTUATOR INSTALLATION [MANUAL AIR CONDITIONER (US)]<\/a>.)<\/p>\n<p class=\"list\">\n<p class=\"list\">3.Connect the mode actuator connector.<\/p>\n<p class=\"list\">\n<p class=\"list\">4.Connect the M-MDS to the DLC-2.<\/p>\n<p class=\"list\">\n<p class=\"list\">5.Operate the mode actuator using the simulation function. (See <a href=\"SM2337318\">SIMULATION INSPECTION<\/a>.)(See <a href=\"SM2335668\">SIMULATION TABLE [DASH-ELECTRICAL SUPPLY UNIT (US)]<\/a>.)<\/p>\n<p class=\"list\">\n<p class=\"list\">6.Verify that the mode actuator operation condition is as shown in the figure.<\/p>\n<p class=\"list\">\n<table class=\"figure-flame-non\">\n<tbody>\n<tr>\n<td>\n<table class=\"figure-non-float\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzw00027688.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"figure-caption\">am3zzw00027688<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"list\">7.If it cannot be operated, replace the mode actuator. (See <a href=\"SM2566292\">AIRFLOW MODE ACTUATOR REMOVAL [MANUAL AIR CONDITIONER (US)]<\/a>.)(See <a href=\"SM2566293\">AIRFLOW MODE ACTUATOR INSTALLATION [MANUAL AIR CONDITIONER (US)]<\/a>.)<\/p>\n<p class=\"list\">\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id0740a280170002\" id=\"id0740a280170002\"><\/a><\/p>\n<p class=\"servinfosub-title\">Position sensor inspection<\/p>\n<p class=\"list\">1.Switch the ignition ON (engine on).<\/p>\n<p class=\"list\">\n<p class=\"list\">2.Connect the M-MDS to the DLC-2.<\/p>\n<p class=\"list\">\n<p class=\"list\">3.Display PID \u201cMODE_ACTAT_POS\u201d using the M-MDS. (See <a href=\"SM2337317\">PID\/DATA MONITOR INSPECTION<\/a>.)(See <a href=\"SM2335667\">PID\/DATA MONITOR TABLE [DASH-ELECTRICAL SUPPLY UNIT (US)]<\/a>.)<\/p>\n<p class=\"list\">\n<p class=\"list\">4.Operate the mode switch.<\/p>\n<p class=\"list\">\n<p class=\"list\">5.Verify that the PID value conforms to the mode switch operation.<\/p>\n<p class=\"list\">\n<p class=\"list\">6.If it cannot be verified, replace the mode actuator. (See <a href=\"SM2566292\">AIRFLOW MODE ACTUATOR REMOVAL [MANUAL AIR CONDITIONER (US)]<\/a>.)(See <a href=\"SM2566293\">AIRFLOW MODE ACTUATOR INSTALLATION [MANUAL AIR CONDITIONER (US)]<\/a>.)<\/p>\n<p class=\"list\">\n<\/div>\n<div class=\"ATTACHMENTS\"><\/div>\n<div class=\"attr VTOC_FILENAME content c2\"><!--\n                        am3zz0740y4w0000003 --><\/div>\n<div class=\"attr SIE_ID content c2\"><!--\n                        id0740a2801700.ent --><\/div>\n<p><!--\n*****************************\nERROR: Schema not found. TYPE=META REFERENCEKEY=SERVICE_MANUALS ROOT=null\n*****************************\n--><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>AIRFLOW MODE ACTUATOR INSPECTION [MANUAL AIR CONDITIONER] SM2566283 id0740a2801700 Actuator inspection 1.Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION\/CONNECTION [(US)].) 2.Remove the airflow mode actuator. (See AIRFLOW MODE ACTUATOR REMOVAL [MANUAL AIR CONDITIONER (US)].)(See AIRFLOW MODE ACTUATOR INSTALLATION [MANUAL AIR CONDITIONER (US)].) 3.Connect the mode actuator connector. 4.Connect the M-MDS to the DLC-2. 5.Operate the mode actuator using the simulation function. (See SIMULATION INSPECTION.)(See SIMULATION TABLE [DASH-ELECTRICAL SUPPLY UNIT (US)].) 6.Verify that the [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-10385","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/10385","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/comments?post=10385"}],"version-history":[{"count":0,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/10385\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/media?parent=10385"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}