{"id":10346,"date":"2022-03-10T20:30:55","date_gmt":"2022-03-10T20:30:55","guid":{"rendered":"https:\/\/www.hexorcism.com\/19BP\/sm2566243\/"},"modified":"2022-03-10T20:30:55","modified_gmt":"2022-03-10T20:30:55","slug":"sm2566243","status":"publish","type":"page","link":"https:\/\/www.hexorcism.com\/19BP\/sm2566243\/","title":{"rendered":"NO COOL AIR [MANUAL AIR CONDITIONER (US)]"},"content":{"rendered":"<div class=\"detailsTabContent\">\n<h3 class=\"c1\">NO COOL AIR [MANUAL AIR CONDITIONER (US)]<\/h3>\n<\/div>\n<p>SM2566243<\/p>\n<div class=\"node SERVICE_MANUALS\"><\/p>\n<div class=\"textleft\">\n<div class=\"attr CONTENT content c2\">\n<hr \/>\n<p class=\"servinfo-title-id\" align=\"right\">id0703c27009c5<\/p>\n<p clear=\"all\">\n<table class=\"table-flame\" border=\"1\">\n<thead>\n<tr>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Troubleshooting item<\/p>\n<\/th>\n<th id=\"\" align=\"left\" colspan=\"2\">\n<p class=\"thead\">No cool air<\/p>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\"><span>Description<\/span><\/div>\n<\/td>\n<td id=\"\" align=\"left\" colspan=\"2\">\n<div class=\"list\">\u2022 Magnetic clutch does not operate<\/div>\n<div class=\"list\">\u2022 No cool airflow even if airflow temperature setting is MAX COLD<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\"><span>Possible cause<\/span><\/div>\n<\/td>\n<td id=\"\" align=\"left\" colspan=\"2\">\n<dl>\n<dd>\n<div class=\"attention3-label\">Note<\/div>\n<\/dd>\n<dd>\n<div class=\"attention3 list\">\u2022 If the engine coolant temperature increases due to a cooling system malfunction, the fail-safe function disables the A\/C operation.<\/div>\n<\/dd>\n<\/dl>\n<div class=\"list\">\u2022 A\/C request signal is not input to PCM<\/div>\n<dl>\n<dd class=\"list\">\n<div class=\"list\">\u2015 Communication error between dash electrical supply unit and body control module (BCM)<\/div>\n<div class=\"list\">\u2015 Communication error between body control module (BCM) and PCM<\/div>\n<\/dd>\n<\/dl>\n<div class=\"list\">\u2022 Magnetic clutch malfunction<\/div>\n<dl>\n<dd class=\"list\">\n<div class=\"list\">\u2015 Operation malfunction<\/div>\n<div class=\"list\">\u2015 Clearance adjustment malfunction<\/div>\n<\/dd>\n<\/dl>\n<div class=\"list\">\u2022 Refrigerant pressure sensor malfunction<\/div>\n<div class=\"list\">\u2022 A\/C compressor malfunction<\/div>\n<div class=\"list\">\u2022 Improper refrigerant charging amount<\/div>\n<div class=\"list\">\u2022 Evaporator temperature sensor malfunction<\/div>\n<div class=\"list\">\u2022 Open circuit or short to ground in wiring harness between evaporative temperature sensor and dash-electrical supply unit<\/div>\n<div class=\"list\">\u2022 Open circuit in A\/C relay signal circuit<\/div>\n<div class=\"list\">\u2022 Short to power supply in A\/C relay signal circuit<\/div>\n<div class=\"list\">\u2022 Open circuit in magnetic clutch power supply circuit<\/div>\n<div class=\"list\">\u2022 Short to ground in magnetic clutch power supply circuit<\/div>\n<div class=\"list\">\u2022 Open circuit in A\/C relay power supply circuit<\/div>\n<div class=\"list\">\u2022 Short to ground in A\/C relay power supply circuit<\/div>\n<div class=\"list\">\u2022 Open circuit in magnetic clutch signal circuit<\/div>\n<div class=\"list\">\u2022 Short to ground in magnetic clutch signal circuit<\/div>\n<div class=\"list\">\u2022 A\/C relay malfunction<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" colspan=\"3\"><img decoding=\"async\" src=\"..\/assets\/am3zzw00031399.png\" \/><\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" colspan=\"2\"><img decoding=\"async\" src=\"..\/assets\/am3zzw00022016.png\" \/><\/td>\n<td id=\"\" align=\"center\"><img decoding=\"async\" src=\"..\/assets\/am3zzw00022017.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"list\">\u2022 When performing an asterisked (*) troubleshooting inspection, shake the wiring harness and connectors while performing the inspection to discover whether poor contact points are the cause of any intermittent malfunctions. If there is a problem, check to make sure connectors, terminals and wiring harnesses are connected correctly and undamaged.<\/div>\n<p clear=\"all\">\n<p class=\"table-title\">Diagnostic Procedure<\/p>\n<table class=\"table-flame\" border=\"1\">\n<thead>\n<tr>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Step<\/p>\n<\/th>\n<th id=\"\" align=\"center\" colspan=\"2\">\n<p class=\"thead\">Inspection<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Action<\/p>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">1<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">VERIFY AIRFLOW CONDITION<\/div>\n<div class=\"list\">\u2022 Switch the ignition ON (engine off or on).<\/div>\n<div class=\"list\">\u2022 Set the airflow volume control dial to <span>1 or more<\/span>.<\/div>\n<div class=\"list\">\u2022 Does air flow from the vent after operating the blower motor?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to Step 1 of the following troubleshooting.<\/div>\n<div class=\"list\">\u2022 <a href=\"SM2335685\">INSUFFICIENT AIR (OR NO AIR) BLOWN FROM VENTS [MANUAL AIR CONDITIONER]<\/a><\/div>\n<div class=\"list\">\u2022 <a href=\"SM2335686\">AMOUNT OF AIR BLOWN FROM VENTS DOES NOT CHANGE [MANUAL AIR CONDITIONER]<\/a><\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">2<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT A\/C COMPRESSOR OPERATION<\/div>\n<div class=\"list\">\u2022 Start engine.<\/div>\n<div class=\"list\">\u2022 Turn A\/C switch on.<\/div>\n<div class=\"list\">\u2022 Does A\/C compressor operate?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to Step 1 of the following troubleshooting.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2335690\">AIR FROM VENTS NOT COLD ENOUGH [MANUAL AIR CONDITIONER]<\/a>.)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">3<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">VERIFY DTCs FOR RELATED MODULES<\/div>\n<div class=\"list\">\u2022 Verify DTCs using the M-MDS.<\/div>\n<dl>\n<dd class=\"list\">\n<div class=\"list\">\u2015 PCM (See <a href=\"SM2337315\">DTC INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2015 Dash-electrical supply unit (See <a href=\"SM2337315\">DTC INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2015 Body control module (BCM) (See <a href=\"SM2337315\">DTC INSPECTION<\/a>.)<\/div>\n<\/dd>\n<\/dl>\n<div class=\"list\">\u2022 Are any DTCs displayed?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the applicable DTC inspection.<\/div>\n<div class=\"list\">\u2015 PCM (See <a href=\"SM2515115\">DTC TABLE [PCM (SKYACTIV-G (US))]<\/a>.)<\/div>\n<div class=\"list\">\u2015 Dash-electrical supply unit (See <a href=\"SM2335558\">DTC TABLE [DASH-ELECTRICAL SUPPLY UNIT (US)]<\/a>.)<\/div>\n<div class=\"list\">\u2015 Body control module (BCM) (See <a href=\"SM2566350\">DTC TABLE [BODY CONTROL MODULE (BCM) (US)]<\/a>.)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">4<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">VERIFY MAGNETIC CLUTCH OPERATION<\/div>\n<div class=\"list\">\u2022 Access PCM PID A\/C_SW using the M-MDS. (See <a href=\"SM2337317\">PID\/DATA MONITOR INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Start engine.<\/div>\n<div class=\"list\">\u2022 Turn the PID A\/C_SW to ON from OFF using the M-MDS simulation function. (See <a href=\"SM2337318\">SIMULATION INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the magnetic clutch engaged\/disengaged according to the simulation function operation?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to Step 9.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">5<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">VERIFY MEASURED VALUE OF A\/C PRESSURE SENSOR<\/div>\n<div class=\"list\">\u2022 Access PCM PIDs AC_PRES_AFT_COMP and AC_PRES_BEF_EXP_VLV using the M-MDS. (See <a href=\"SM2337317\">PID\/DATA MONITOR INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Monitor the AC_PRES_AFT_COMP and AC_PRES_BEF_EXP_VLV PIDs while turning on and off the air conditioner by switching the control panel.<\/div>\n<div class=\"list\">\u2022 Are PIDs normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to Step 7.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">6<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT REFRIGERANT PRESSURE SENSOR<\/div>\n<div class=\"list\">\u2022 Inspect the refrigerant pressure sensor. (See <a href=\"SM2566296\">REFRIGERANT PRESSURE SENSOR INSPECTION [MANUAL AIR CONDITIONER (US)]<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the refrigerant pressure sensor normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Inspect the following and repair or replace if necessary.<\/div>\n<div class=\"list\">\u2022 Refrigerant charge amount (if refrigerant has discharged completely, replace receiver\/drier( <sup>*1<\/sup>)) (See <a href=\"SM2335718\">RECEIVER\/DRIER REMOVAL\/INSTALLATION [SKYACTIV-G 2.0, SKYACTIV-G 2.5]<\/a>.)<\/div>\n<div class=\"list\">\u2022 A\/C compressor (See <a href=\"SM2335715\">A\/C COMPRESSOR REMOVAL\/INSTALLATION [SKYACTIV-G 2.0, SKYACTIV-G 2.5]<\/a>.)<\/div>\n<div class=\"tbody\">Perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Replace refrigerant pressure sensor, then perform the repair completion verification.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2566295\">REFRIGERANT PRESSURE SENSOR REMOVAL\/INSTALLATION [MANUAL AIR CONDITIONER (US)]<\/a>.)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">7<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">VERIFY MEASURED VALUE OF EVAPORATOR TEMPERATURE SENSOR<\/div>\n<div class=\"list\">\u2022 Access dash-electrical supply unit PID EVA_TMP using the M-MDS. (See <a href=\"SM2337317\">PID\/DATA MONITOR INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Turn the climate control unit A\/C switch on and off while the PID EVA_TMP is displayed.<\/div>\n<div class=\"list\">\u2022 Is the PID normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">8<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT EVAPORATOR TEMPERATURE SENSOR<\/div>\n<div class=\"list\">\u2022 Inspect the evaporator temperature sensor. (See <a href=\"SM2566280\">EVAPORATOR TEMPERATURE SENSOR INSPECTION [MANUAL AIR CONDITIONER]<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the evaporator temperature sensor normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Refer to the wiring diagram and verify whether or not there is a common connector between evaporator temperature sensor terminal and climate control unit terminal.<\/div>\n<div class=\"list-title\">If there is a common connector:<\/div>\n<div class=\"list\">\u2022 Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection.<\/div>\n<div class=\"list\">\u2022 Repair or replace the malfunctioning part.<\/div>\n<div class=\"list-title\">If there is no common connector:<\/div>\n<div class=\"list\">\u2022 Repair or replace the wiring harness.<\/div>\n<div class=\"tbody\">Perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Replace the evaporator temperature sensor, then perform the repair completion verification.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2566279\">EVAPORATOR TEMPERATURE SENSOR REMOVAL\/INSTALLATION [MANUAL AIR CONDITIONER (US)]<\/a>.)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">9<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">DETERMINE IF MALFUNCTION IS CAUSED BY A\/C RELAY CIRCUIT MALFUNCTION OR PCM MALFUNCTION<\/div>\n<div class=\"list\">\u2022 Short circuit between A\/C relay terminal E (A\/C control signal) and ground.<\/div>\n<div class=\"list\">\u2022 Is there cool airflow?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair the short circuit and go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to Step 13.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">10<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT A\/C RELAY CONTROL CIRCUIT FOR OPEN CIRCUIT<\/div>\n<div class=\"list\">\u2022 Inspect the applicable circuit for open circuit. (See <a href=\"SM2337319\">CIRCUIT INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the circuit normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location and perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">11<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT A\/C RELAY CONTROL CIRCUIT FOR SHORT TO GROUND<\/div>\n<div class=\"list\">\u2022 Inspect the applicable circuit for a short to ground. (See <a href=\"SM2337319\">CIRCUIT INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the circuit normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location and perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">12<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT MAGNETIC CLUTCH<\/div>\n<div class=\"list\">\u2022 Inspect the magnetic clutch. (See <a href=\"SM2335705\">MAGNETIC CLUTCH INSPECTION [SKYACTIV-G 2.0, SKYACTIV-G 2.5]<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the magnetic clutch normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Replace the magnetic clutch, then perform the repair completion verification.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2335703\">MAGNETIC CLUTCH DISASSEMBLY\/ASSEMBLY [SKYACTIV-G 2.0, SKYACTIV-G 2.5]<\/a>.)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">13*<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT MAGNETIC CLUTCH POWER SUPPLY CIRCUIT FOR SHORT TO GROUND AND OPEN CIRCUIT<\/div>\n<div class=\"list\">\u2022 Inspect the power supply circuit for an open circuit and short to ground. (See <a href=\"SM2337319\">CIRCUIT INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the circuit normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location and perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">14*<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT A\/C RELAY POWER SUPPLY CIRCUIT FOR OPEN CIRCUIT<\/div>\n<div class=\"list\">\u2022 Inspect the power supply circuit for an open circuit. (See <a href=\"SM2337319\">CIRCUIT INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the circuit normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location and perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">15*<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT A\/C RELAY POWER SUPPLY CIRCUIT FOR SHORT TO GROUND<\/div>\n<div class=\"list\">\u2022 Inspect the applicable circuit for a short to ground. (See <a href=\"SM2337319\">CIRCUIT INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the circuit normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location and perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">16*<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT MAGNETIC CLUTCH CONTROL CIRCUIT FOR OPEN CIRCUIT<\/div>\n<div class=\"list\">\u2022 Inspect the applicable circuit for open circuit. (See <a href=\"SM2337319\">CIRCUIT INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the circuit normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location and perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">17*<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT MAGNETIC CLUTCH CONTROL CIRCUIT FOR SHORT TO GROUND<\/div>\n<div class=\"list\">\u2022 Inspect the applicable circuit for a short to ground. (See <a href=\"SM2337319\">CIRCUIT INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the circuit normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Replace the A\/C relay and perform the repair completion verification.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2566431\">RELAY LOCATION [(US)]<\/a>.)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location and perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">Repair completion verification<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">VERIFY THAT MALFUNCTION SYMPTOM DOES NOT RECUR AFTER REPAIR<\/div>\n<div class=\"list\">\u2022 Does cool air discharge from the vents? (Are the results of refrigerant system performance test normal?) (See <a href=\"SM2566247\">REFRIGERANT SYSTEM PERFORMANCE TEST [(US)]<\/a>.)<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Troubleshooting completed. Explain repairs to customer.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Refer to the controller area network (CAN) malfunction diagnosis flow to inspect for a CAN communication error.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2566441\">CONTROLLER AREA NETWORK (CAN) MALFUNCTION DIAGNOSIS FLOW [(US)]<\/a>.)<\/div>\n<div class=\"tbody\">If the CAN communication is normal, perform the diagnosis from Step 1.<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"deflist\">*1:If the refrigerant has completely leaked out, ambient air may penetrate the refrigerant system and the desiccant in the receiver\/drier may absorb moisture in the ambient air resulting in saturation. If the refrigerant system is used under this condition, rust may generate in the A\/C compressor due to the moisture, causing secondary problems such as A\/C compressor lock or abnormal noise. Therefore, it will be necessary to replace the receiver\/drier. (See <a href=\"SM2335718\">RECEIVER\/DRIER REMOVAL\/INSTALLATION [SKYACTIV-G 2.0, SKYACTIV-G 2.5]<\/a>.)<\/div>\n<\/div>\n<div class=\"ATTACHMENTS\"><\/div>\n<div class=\"attr VTOC_FILENAME content c2\"><!--\n                        am3zz0703c2w0000088 --><\/div>\n<div class=\"attr SIE_ID content c2\"><!--\n                        id0703c27009c5.ent --><\/div>\n<p><!--\n*****************************\nERROR: Schema not found. TYPE=META REFERENCEKEY=SERVICE_MANUALS ROOT=null\n*****************************\n--><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>NO COOL AIR [MANUAL AIR CONDITIONER (US)] SM2566243 id0703c27009c5 Troubleshooting item No cool air Description \u2022 Magnetic clutch does not operate \u2022 No cool airflow even if airflow temperature setting is MAX COLD Possible cause Note \u2022 If the engine coolant temperature increases due to a cooling system malfunction, the fail-safe function disables the A\/C operation. \u2022 A\/C request signal is not input to PCM \u2015 Communication error between dash electrical supply unit and body [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-10346","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/10346","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/comments?post=10346"}],"version-history":[{"count":0,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/10346\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/media?parent=10346"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}