{"id":10273,"date":"2022-03-10T20:30:54","date_gmt":"2022-03-10T20:30:54","guid":{"rendered":"https:\/\/www.hexorcism.com\/19BP\/sm2566145\/"},"modified":"2022-03-10T20:30:54","modified_gmt":"2022-03-10T20:30:54","slug":"sm2566145","status":"publish","type":"page","link":"https:\/\/www.hexorcism.com\/19BP\/sm2566145\/","title":{"rendered":"TRANSAXLE OVERHEATS [ET6A-EL (US)]"},"content":{"rendered":"<div class=\"detailsTabContent\">\n<h3 class=\"c1\">TRANSAXLE OVERHEATS [ET6A-EL (US)]<\/h3>\n<\/div>\n<p>SM2566145<\/p>\n<div class=\"node SERVICE_MANUALS\"><\/p>\n<div class=\"textleft\">\n<div class=\"attr CONTENT content c2\">\n<hr \/>\n<p class=\"servinfo-title-id\" align=\"right\">id0503n21026n5<\/p>\n<p clear=\"all\">\n<table class=\"table-flame\" border=\"1\">\n<thead>\n<tr>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Troubleshooting item<\/p>\n<\/th>\n<th id=\"\" align=\"left\">\n<p class=\"thead\">Transaxle overheats<\/p>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\"><span>Description<\/span><\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">\u2022 Burnt smell emitted from the transaxle.<\/div>\n<div class=\"list\">\u2022 Smoke is emitted from the transaxle.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\"><span>Possible cause<\/span><\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">1. Signal malfunction<\/div>\n<dl>\n<dd class=\"list\">\n<div class=\"list\">\u2015 APP sensor malfunction<\/div>\n<div class=\"list\">\u2015 Brake switch malfunction<\/div>\n<div class=\"list\">\u2015 CKP sensor malfunction<\/div>\n<div class=\"list\">\u2015 ECT sensor malfunction<\/div>\n<\/dd>\n<\/dl>\n<div class=\"list\">2. ATF malfunction<\/div>\n<div class=\"list\">3. Oil cooler malfunction<\/div>\n<div class=\"list\">4. Control valve body malfunction<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\"><span>System wiring diagram<\/span><\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">\u2022 Not applicable<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\"><span>Connector diagram<\/span><\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"list\">\u2022 Not applicable<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p clear=\"all\">\n<p class=\"table-title\">Diagnostic procedure<\/p>\n<table class=\"table-flame\" border=\"1\">\n<thead>\n<tr>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Step<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Inspection<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Results<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Action<\/p>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">1<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT SIGNAL PARTS FOR MALFUNCTION<\/div>\n<div class=\"list\">\u2022 Inspect the value at the following PCM PIDs using the M-MDS. (See <a href=\"SM2337317\">PID\/DATA MONITOR INSPECTION<\/a>.)<\/div>\n<dl>\n<dd class=\"list\">\n<div class=\"list\">\u2015 APP (APP sensor)<\/div>\n<div class=\"list\">\u2015 ECT (ECT sensor)<\/div>\n<div class=\"list\">\u2015 ENG_RPM (CKP sensor)<\/div>\n<\/dd>\n<\/dl>\n<div class=\"list\">\u2022 Is there any malfunction? (See <a href=\"SM2565542\">PID\/DATA MONITOR TABLE [PCM (SKYACTIV-G (US))]<\/a>.)<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace any malfunctioning parts according to the inspection result.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">2<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT SIGNAL PARTS FOR MALFUNCTION<\/div>\n<div class=\"list\">\u2022 Inspect the value at the following ESU PIDs using the M-MDS. (See <a href=\"SM2337317\">PID\/DATA MONITOR INSPECTION<\/a>.)<\/div>\n<dl>\n<dd class=\"list\">\n<div class=\"list\">\u2015 BRK_SW (Brake switch)<\/div>\n<\/dd>\n<\/dl>\n<div class=\"list\">\u2022 Is there any malfunction? (See <a href=\"SM2566313\">PID\/DATA MONITOR TABLE [ELECTRICAL SUPPLY UNIT (ESU) (US)]<\/a>.)<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace any malfunctioning parts according to the inspection result.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">3<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">INSPECT ATF LEVEL<\/div>\n<div class=\"list\">\u2022 Inspect the ATF level. (See <a href=\"SM2566179\">AUTOMATIC TRANSAXLE FLUID (ATF) INSPECTION [ET6A-EL (US)]<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is there any malfunction?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Adjust the ATF level to the specification.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2566182\">AUTOMATIC TRANSAXLE FLUID (ATF) ADJUSTMENT [ET6A-EL (US)]<\/a>.)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">4<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">VISUALLY INSPECT OIL COOLER<\/div>\n<div class=\"list\">\u2022 Visually inspect the oil cooler.<\/div>\n<div class=\"list\">\u2022 Is there any malfunction?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace any malfunctioning parts according to the inspection result.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2335462\">OIL COOLER REMOVAL\/INSTALLATION [ET6A-EL (SKYACTIV-G 2.0, SKYACTIV-G 2.5) (US)]<\/a>.)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">5<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">VERIFY IF MALFUNCTION CAUSE IS CONTROL VALVE BODY<\/div>\n<div class=\"list\">\u2022 Inspect the value at the following TCM PIDs using the M-MDS. (See <a href=\"SM2337317\">PID\/DATA MONITOR INSPECTION<\/a>.)<\/div>\n<dl>\n<dd class=\"list\">\n<div class=\"list\">\u2015 ECU_TEMP_A<\/div>\n<div class=\"list\">\u2015 ECU_TEMP_B<\/div>\n<div class=\"list\">\u2015 ECU_TEMP_C<\/div>\n<div class=\"list\">\u2015 GEAR_SEL<\/div>\n<div class=\"list\">\u2015 LINE_PRES_COMD<\/div>\n<div class=\"list\">\u2015 CLTCH_OIL_PRES_SW1<\/div>\n<div class=\"list\">\u2015 CLTCH_OIL_PRES_SW2<\/div>\n<div class=\"list\">\u2015 CLTCH_OIL_PRES_SW3<\/div>\n<div class=\"list\">\u2015 CLTCH_OIL_PRES_SW4<\/div>\n<div class=\"list\">\u2015 OSS<\/div>\n<div class=\"list\">\u2015 SHIFT_SOL_B_CUR_ACT<\/div>\n<div class=\"list\">\u2015 SHIFT_SOL_C_CUR_ACT<\/div>\n<div class=\"list\">\u2015 SHIFT_SOL_D_CUR_ACT<\/div>\n<div class=\"list\">\u2015 SHIFT_SOL_E_CUR_ACT<\/div>\n<div class=\"list\">\u2015 TRQ_CON_CLTCH_CUR_ACT<\/div>\n<div class=\"list\">\u2015 TRQ_CON_CLTCH_PRES<\/div>\n<div class=\"list\">\u2015 SHIFT_SOL_A_CUR<\/div>\n<div class=\"list\">\u2015 SHIFT_SOL_A_PRES<\/div>\n<div class=\"list\">\u2015 TR1<\/div>\n<div class=\"list\">\u2015 TSS<\/div>\n<div class=\"list\">\u2015 VSS<\/div>\n<\/dd>\n<\/dl>\n<div class=\"list\">\u2022 Is there any malfunction? (See <a href=\"SM2565981\">PID\/DATA MONITOR TABLE [TCM (ET6A-EL) (US)]<\/a>.)<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Replace the control valve body.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2335463\">CONTROL VALVE BODY REMOVAL\/INSTALLATION [ET6A-EL (US)]<\/a>.)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Symptom troubleshooting is completed.<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"ATTACHMENTS\"><\/div>\n<div class=\"attr VTOC_FILENAME content c2\"><!--\n                        am3zz0503n2w0000092 --><\/div>\n<div class=\"attr SIE_ID content c2\"><!--\n                        id0503n21026n5.ent --><\/div>\n<p><!--\n*****************************\nERROR: Schema not found. TYPE=META REFERENCEKEY=SERVICE_MANUALS ROOT=null\n*****************************\n--><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>TRANSAXLE OVERHEATS [ET6A-EL (US)] SM2566145 id0503n21026n5 Troubleshooting item Transaxle overheats Description \u2022 Burnt smell emitted from the transaxle. \u2022 Smoke is emitted from the transaxle. Possible cause 1. Signal malfunction \u2015 APP sensor malfunction \u2015 Brake switch malfunction \u2015 CKP sensor malfunction \u2015 ECT sensor malfunction 2. ATF malfunction 3. Oil cooler malfunction 4. Control valve body malfunction System wiring diagram \u2022 Not applicable Connector diagram \u2022 Not applicable Diagnostic procedure Step Inspection Results Action [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-10273","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/10273","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/comments?post=10273"}],"version-history":[{"count":0,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/10273\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/media?parent=10273"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}