{"id":10002,"date":"2022-03-10T20:30:52","date_gmt":"2022-03-10T20:30:52","guid":{"rendered":"https:\/\/www.hexorcism.com\/19BP\/sm2565557\/"},"modified":"2022-03-10T20:30:52","modified_gmt":"2022-03-10T20:30:52","slug":"sm2565557","status":"publish","type":"page","link":"https:\/\/www.hexorcism.com\/19BP\/sm2565557\/","title":{"rendered":"DTC P0130:00 [PCM (SKYACTIV-G (US))]"},"content":{"rendered":"<div class=\"detailsTabContent\">\n<h3 class=\"c1\">DTC P0130:00 [PCM (SKYACTIV-G (US))]<\/h3>\n<\/div>\n<p>SM2565557<\/p>\n<div class=\"node SERVICE_MANUALS\"><\/p>\n<div class=\"textleft\">\n<div class=\"attr CONTENT content c2\">\n<hr \/>\n<p class=\"servinfo-title-id\" align=\"right\">id0102t47021u0<\/p>\n<dl>\n<dd>\n<div class=\"attention3-label\">Note<\/div>\n<\/dd>\n<dd>\n<div class=\"attention3 list\">\u2022 To determine the malfunctioning part, proceed with the diagnostics from &#8220;Function Inspection Using M-MDS&#8221;.<\/div>\n<\/dd>\n<\/dl>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id0102t47021u001\" id=\"id0102t47021u001\"><\/a><\/p>\n<p class=\"servinfosub-title\">Details On DTCs<\/p>\n<p clear=\"all\">\n<table class=\"table-flame\" border=\"1\">\n<thead>\n<tr>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Description<\/p>\n<\/th>\n<th id=\"\" align=\"left\" colspan=\"3\">\n<p class=\"thead\">Voltage problem between PCM terminal 1S and PCM terminal 1M<\/p>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"5\">\n<div class=\"tbody\"><span>Detection condition<\/span><\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Determination conditions<\/div>\n<\/td>\n<td id=\"\" align=\"left\" colspan=\"2\">\n<div class=\"list\">\u2022 A condition in which the voltage between PCM terminals 1S and 1M exceeds the specified range continues for the specified period or more.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Preconditions<\/div>\n<\/td>\n<td id=\"\" align=\"left\" colspan=\"2\">\n<div class=\"list\">\u2022 Switch the ignition ON (engine off or on)<\/div>\n<div class=\"list\">\u2022 Battery voltage: <span>11\u201418 V<\/span> <sup>*1<\/sup><\/div>\n<div class=\"list\">\u2022 The following DTC is not detected:<\/div>\n<dl>\n<dd class=\"list\">\n<div class=\"list\">\u2015 Internal PCM malfunction: P064D:00<\/div>\n<\/dd>\n<\/dl>\n<div class=\"list\"><sup>*1<\/sup>: Standard can be verified by displaying PIDs using M-MDS<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Drive cycle<\/div>\n<\/td>\n<td id=\"\" align=\"left\" colspan=\"2\">\n<div class=\"list\">\u2022 2<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Self test type<\/div>\n<\/td>\n<td id=\"\" align=\"left\" colspan=\"2\">\n<div class=\"list\">\u2022 CMDTC self test, KOER self test<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Sensor used<\/div>\n<\/td>\n<td id=\"\" align=\"left\" colspan=\"2\">\n<div class=\"list\">\u2022 A\/F sensor<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\"><span>Fail-safe function<\/span><\/div>\n<\/td>\n<td id=\"\" align=\"left\" colspan=\"3\">\n<div class=\"list\">\u2022 Fixes duty value of A\/F sensor heater<\/div>\n<div class=\"list\">\u2022 Stops fuel feedback control of A\/F sensor<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\"><span>Vehicle status when DTCs are output<\/span><\/div>\n<\/td>\n<td id=\"\" align=\"left\" colspan=\"3\">\n<div class=\"list\">\u2022 Not applicable<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\"><span>Possible cause<\/span><\/div>\n<\/td>\n<td id=\"\" align=\"left\" colspan=\"3\">\n<div class=\"list\">\u2022 A\/F sensor connector or terminals malfunction<\/div>\n<div class=\"list\">\u2022 PCM connector or terminals malfunction<\/div>\n<div class=\"list\">\u2022 Deterioration in any of the following A\/F sensor circuits.<\/div>\n<dl>\n<dd class=\"list\">\n<div class=\"list\">\u2015 Control circuit<\/div>\n<div class=\"list\">\u2015 Signal circuit<\/div>\n<\/dd>\n<\/dl>\n<div class=\"list\">\u2022 A\/F sensor malfunction<\/div>\n<div class=\"list\">\u2022 PCM malfunction<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" colspan=\"4\"><img decoding=\"async\" src=\"..\/assets\/am3zzw00033678.png\" \/><\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" colspan=\"4\"><img decoding=\"async\" src=\"..\/assets\/am3zzw00033679.png\" \/><\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" colspan=\"4\"><img decoding=\"async\" src=\"..\/assets\/am3zzw00033680.png\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id0102t47021u002\" id=\"id0102t47021u002\"><\/a><\/p>\n<p class=\"servinfosub-title\">Function Explanation (DTC Detection Outline)<\/p>\n<div class=\"list\">\u2022 If the voltage between PCM terminal 1S and PCM terminal 1M exceeds the specified range with the A\/F sensor activated, the element in the A\/F sensor could deteriorate. To prevent this, the PCM stops control of the A\/F sensor and stores a DTC.<\/div>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id0102t47021u003\" id=\"id0102t47021u003\"><\/a><\/p>\n<p class=\"servinfosub-title\">Repeatability Verification Procedure<\/p>\n<div class=\"list\">1. Warm up the engine to allow the engine coolant temperature to reach <span>80 \u00b0C {176 \u00b0F} or more<\/span>.<\/div>\n<div class=\"list\">2. Start the engine and leave it idling for <span>1 min<\/span>.<\/p>\n<dl>\n<dd>\n<div class=\"attention3-label\">Note<\/div>\n<\/dd>\n<dd>\n<div class=\"attention3 list\">\u2022 Match the engine coolant temperature in the recorded freeze frame data\/snapshot data, the vehicle speed, and engine speed values to the best extent possible while driving the vehicle.<\/div>\n<\/dd>\n<\/dl>\n<\/div>\n<div class=\"list\">3. Try to reproduce the malfunction by driving the vehicle for <span>5 min<\/span> based on the values in the freeze frame data\/snapshot data.<\/div>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id0102t47021u004\" id=\"id0102t47021u004\"><\/a><\/p>\n<p class=\"servinfosub-title\">PID Item\/Simulation Item Used In Diagnosis<\/p>\n<p clear=\"all\">\n<p class=\"table-title\">PID\/DATA monitor item table<\/p>\n<table class=\"table-flame\" border=\"1\">\n<thead>\n<tr>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">PIDs<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Reference<\/p>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">A\/F_SEN_CUR<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">(See <a href=\"SM2565542\">PID\/DATA MONITOR TABLE [PCM (SKYACTIV-G (US))]<\/a>.)<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id0102t47021u005\" id=\"id0102t47021u005\"><\/a><\/p>\n<p class=\"servinfosub-title\">Function Inspection Using M-MDS<\/p>\n<p clear=\"all\">\n<table class=\"table-flame\" border=\"1\">\n<thead>\n<tr>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Step<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Inspection<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Results<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Action<\/p>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">1<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">PURPOSE: VERIFY RELATED REPAIR INFORMATION OR SERVICE INFORMATION AVAILABILITY<\/div>\n<div class=\"list\">\u2022 Verify related Service Bulletins, on-line repair information, or Service Information availability.<\/div>\n<div class=\"list\">\u2022 Is any related Information available?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Perform repair or diagnosis according to the available information.<\/div>\n<div class=\"list\">\u2022 If the vehicle is not repaired, go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">2<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"entry-title\">PURPOSE: RECORD VEHICLE STATUS WHEN DTC WAS DETECTED TO UTILIZE WITH REPEATABILITY VERIFICATION<\/div>\n<div class=\"list\">\u2022 Record the freeze frame data\/snapshot data and diagnostic monitoring test results (A\/F sensor, HO2S related).<\/p>\n<dl>\n<dd>\n<div class=\"attention3-label\">Note<\/div>\n<\/dd>\n<dd>\n<div class=\"attention3 list\">\u2022 Recording can be facilitated using the screen capture function of the PC.<\/div>\n<\/dd>\n<\/dl>\n<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">\u2014<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to Troubleshooting Diagnostic Procedure to perform the procedure from Step 1.<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><br clear=\"all\" \/><br \/>\n<a name=\"id0102t47021u006\" id=\"id0102t47021u006\"><\/a><\/p>\n<p class=\"servinfosub-title\">Troubleshooting Diagnostic Procedure<\/p>\n<div class=\"list-title\">Intention of troubleshooting procedure<\/div>\n<div class=\"list\">\u2022 Step 1\u20142<\/div>\n<dl>\n<dd class=\"list\">\n<div class=\"list\">\u2015 Perform an inspection of the A\/F sensor and PCM-related connectors.<\/div>\n<\/dd>\n<\/dl>\n<div class=\"list\">\u2022 Step 3<\/div>\n<dl>\n<dd class=\"list\">\n<div class=\"list\">\u2015 Inspect the wiring harness between the A\/F sensor and PCM for deterioration.<\/div>\n<\/dd>\n<\/dl>\n<div class=\"list\">\u2022 Step 4<\/div>\n<dl>\n<dd class=\"list\">\n<div class=\"list\">\u2015 Perform a unit inspection of the A\/F sensor.<\/div>\n<\/dd>\n<\/dl>\n<div class=\"list\">\u2022 Repair completion verification<\/div>\n<dl>\n<dd class=\"list\">\n<div class=\"list\">\u2015 Verify that the primary malfunction is resolved and there are no other malfunctions.<\/div>\n<\/dd>\n<\/dl>\n<p clear=\"all\">\n<table class=\"table-flame\" border=\"1\">\n<thead>\n<tr>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Step<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Inspection<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Results<\/p>\n<\/th>\n<th id=\"\" align=\"center\">\n<p class=\"thead\">Action<\/p>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">1<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">PURPOSE: INSPECT A\/F SENSOR CONNECTOR FOR MALFUNCTION<\/div>\n<div class=\"list\">\u2022 Inspect the applicable connector and terminal. (See <a href=\"SM2337320\">CONNECTOR INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Are the connector and terminal normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location and perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">2<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">PURPOSE: INSPECT PCM CONNECTOR FOR MALFUNCTION<\/div>\n<div class=\"list\">\u2022 Inspect the applicable connector and terminal. (See <a href=\"SM2337320\">CONNECTOR INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Are the connector and terminal normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location and perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">3<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">PURPOSE: INSPECT A\/F SENSOR CONTROL CIRCUIT AND SIGNAL CIRCUIT FOR DETERIORATION<\/div>\n<div class=\"list\">\u2022 Inspect the applicable circuit for deterioration. (See <a href=\"SM2337319\">CIRCUIT INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the circuit normal?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair or replace the malfunctioning location and perform the repair completion verification.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">4<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">PURPOSE: DETERMINE INTEGRITY OF A\/F SENSOR<\/div>\n<div class=\"list\">\u2022 Start the engine and warm it up completely.<\/div>\n<div class=\"list\">\u2022 Access the A\/F_SEN_CUR PID using the M-MDS. (See <a href=\"SM2337317\">PID\/DATA MONITOR INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Drive the vehicle under the following conditions.<\/p>\n<dl>\n<dd>\n<div class=\"attention1-label\">Warning<\/div>\n<\/dd>\n<dd>\n<div class=\"attention1\">\n<div class=\"list\">\u2022 When the M-MDS is used to observe monitor system status while driving, be sure to have another technician with you, or record the data in the M-MDS using the PID\/DATA MONITOR AND RECORD capturing function and inspect later.<\/div>\n<div class=\"list\">\u2022 While performing this step, always operate the vehicle in a safe and lawful manner.<\/div>\n<\/div>\n<\/dd>\n<\/dl>\n<\/div>\n<dl>\n<dd class=\"list\">\n<div class=\"list\">\u2015 After increasing the engine speed to <span>3,000 rpm<\/span>, decelerate using engine braking.<\/div>\n<\/dd>\n<\/dl>\n<div class=\"list\">\u2022 Is the displayed PID value as follows?<\/div>\n<dl>\n<dd class=\"list\">\n<div class=\"list\">\u2015 A\/F_SEN_CUR: <span>0.25 mA or more<\/span><\/div>\n<\/dd>\n<\/dl>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Replace the A\/F sensor and perform the repair completion verification.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2565927\">AIR FUEL RATIO (A\/F) SENSOR REMOVAL\/INSTALLATION [SKYACTIV-G (WITH CYLINDER DEACTIVATION (US))]<\/a>.)<\/div>\n<div class=\"tbody\">(See <a href=\"SM2565881\">AIR FUEL RATIO (A\/F) SENSOR REMOVAL\/INSTALLATION [SKYACTIV-G (WITHOUT CYLINDER DEACTIVATION (US))]<\/a>.)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">Repair completion verification 1<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">PURPOSE: VERIFY THAT VEHICLE IS REPAIRED<\/div>\n<div class=\"list\">\u2022 Install\/connect the part removed\/disconnected during the troubleshooting procedure.<\/div>\n<div class=\"list\">\u2022 Clear the DTC recorded in the memory. (See <a href=\"SM2337316\">CLEARING DTC<\/a>.)<\/div>\n<div class=\"list\">\u2022 Replicate the vehicle conditions at the time the DTC was detected using the following procedure.<\/div>\n<dl>\n<dd class=\"list\">\n<div class=\"list\">\u2015 Perform the KOER self test. (See <a href=\"SM2337315\">DTC INSPECTION<\/a>.)<\/div>\n<\/dd>\n<\/dl>\n<div class=\"list\">\u2022 Perform the DTC inspection for the PCM. (See <a href=\"SM2337315\">DTC INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Is the same Pending DTC present?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Refer to the controller area network (CAN) malfunction diagnosis flow to inspect for a CAN communication error.<\/div>\n<div class=\"tbody\">(See <a href=\"SM2566441\">CONTROLLER AREA NETWORK (CAN) MALFUNCTION DIAGNOSIS FLOW [(US)]<\/a>.)<\/div>\n<div class=\"tbody\">If the CAN communication is normal, perform the diagnosis from Step 1.<\/div>\n<div class=\"list\">\u2022 If the malfunction recurs, replace the PCM, then go to the next step. (See <a href=\"SM2565911\">PCM REMOVAL\/INSTALLATION [SKYACTIV-G (WITH CYLINDER DEACTIVATION (US))]<\/a>.) (See <a href=\"SM2565865\">PCM REMOVAL\/INSTALLATION [SKYACTIV-G (WITHOUT CYLINDER DEACTIVATION (US))]<\/a>.)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Go to the next step.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\" rowspan=\"2\">\n<div class=\"tbody\">Repair completion verification 2<\/div>\n<\/td>\n<td id=\"\" align=\"left\" rowspan=\"2\">\n<div class=\"entry-title\">PURPOSE: VERIFY IF OTHER DTCs DISPLAYED<\/div>\n<div class=\"list\">\u2022 Perform the DTC inspection. (See <a href=\"SM2337315\">DTC INSPECTION<\/a>.)<\/div>\n<div class=\"list\">\u2022 Are any other DTCs displayed?<\/div>\n<\/td>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">Yes<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">Repair the malfunctioning location according to the applicable DTC troubleshooting.<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td id=\"\" align=\"center\">\n<div class=\"tbody\">No<\/div>\n<\/td>\n<td id=\"\" align=\"left\">\n<div class=\"tbody\">DTC troubleshooting completed.<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"ATTACHMENTS\"><\/div>\n<div class=\"attr VTOC_FILENAME content c2\"><!--\n                        am3zz0102t4w0000814 --><\/div>\n<div class=\"attr SIE_ID content c2\"><!--\n                        id0102t47021u0.ent --><\/div>\n<p><!--\n*****************************\nERROR: Schema not found. TYPE=META REFERENCEKEY=SERVICE_MANUALS ROOT=null\n*****************************\n--><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>DTC P0130:00 [PCM (SKYACTIV-G (US))] SM2565557 id0102t47021u0 Note \u2022 To determine the malfunctioning part, proceed with the diagnostics from &#8220;Function Inspection Using M-MDS&#8221;. Details On DTCs Description Voltage problem between PCM terminal 1S and PCM terminal 1M Detection condition Determination conditions \u2022 A condition in which the voltage between PCM terminals 1S and 1M exceeds the specified range continues for the specified period or more. Preconditions \u2022 Switch the ignition ON (engine off or on) [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-10002","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/10002","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/comments?post=10002"}],"version-history":[{"count":0,"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/pages\/10002\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.hexorcism.com\/19BP\/wp-json\/wp\/v2\/media?parent=10002"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}