DETERMINING SHORT TO GROUND LOCATION (CAN-BUS No.1) [(US)]
DETERMINING SHORT TO GROUND LOCATION (CAN-BUS No.1) [(US)]
SM2566444
id1002x1001800
-
Caution
-
• Perform the following malfunction diagnosis only when it is diagnosed with a short to ground by CONTROLLER AREA NETWORK (CAN) MALFUNCTION DIAGNOSIS FLOW. (See CONTROLLER AREA NETWORK (CAN) MALFUNCTION DIAGNOSIS FLOW [(US)].)
System Wiring Diagram
|
Determination Procedure
-
Caution
-
• When disconnecting the connector, verify that there is no looseness, damage, deformation, corrosion, or poor connection of the connector terminals.• When inspecting the connector, touch it with a paper clip or similar thin pin without directly inserting a tester probe into the terminal.
Step |
Inspection |
Action |
|
---|---|---|---|
1
|
INSPECT FOR SHORT TO GROUND BETWEEN BODY CONTROL MODULE (BCM) AND CONNECTOR C-40
• Switch the ignition off.
• Disconnect the negative battery cable. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION [(US)])
• Disconnect the connector C-40.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Go to the next step.
|
No
|
Go to Step 3.
|
||
2
|
INSPECT CAN LINE IN BODY CONTROL MODULE (BCM) FOR SHORT TO GROUND
• Disconnect the connector 3 which has body control module (BCM) terminals 3X and 3W.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between the connector C-40 and body control module (BCM) because the wiring harness is shorted to ground.
|
No
|
Replace the body control module (BCM) because there is a short to ground in the body control module (BCM).
|
||
3
|
INSPECT FOR SHORT TO GROUND BETWEEN EPS CONTROL MODULE AND CONNECTOR C-40
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Go to the next step.
|
No
|
Go to Step 5.
|
||
4
|
INSPECT CAN LINE IN EPS CONTROL MODULE FOR SHORT TO GROUND
• Disconnect the EPS control module connector.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between the EPS control module and connector C-40 because the wiring harness is shorted to ground.
|
No
|
Replace the EPS control module because there is a short to ground in the EPS control module.
|
||
5
|
INSPECT FOR SHORT TO GROUND BETWEEN AFS CONTROL MODULE / AUTO LEVELING CONTROL MODULE AND CONNECTOR C-40
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Go to the next step.
|
No
|
Go to Step 7.
|
||
6
|
INSPECT CAN LINE IN AFS CONTROL MODULE / AUTO LEVELING CONTROL MODULE FOR SHORT TO GROUND
• Disconnect the AFS control module / auto leveling control module connector.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between the AFS control module / auto leveling control module and connector C-40 because the wiring harness is shorted to ground.
|
No
|
Replace the AFS control module / auto leveling control module because there is a short to ground in the AFS control module / auto leveling control module.
|
||
7
|
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-40 AND CONNECTOR C-13
• Connect the connector C-40.
• Disconnect the connector C-13.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between the connector C-40 and connector C-13 because the wiring harness is shorted to ground.
|
No
|
Go to the next step.
|
||
8
|
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-13 AND CONNECTOR C-21
• Connect the connector C-13.
• Disconnect the connector C-21.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between the connector C-13 and connector C-21 because the wiring harness is shorted to ground.
|
No
|
Go to the next step.
|
||
9
|
INSPECT FOR SHORT TO GROUND BETWEEN SAS CONTROL MODULE AND CONNECTOR C-21
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Go to the next step.
|
No
|
Go to Step 13.
|
||
10
|
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-21 AND CONNECTORS C-55, C-56
• Disconnect the connectors C-55, C-56.
• Connect the connector C-21.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between the connector C-21 and connectors C-55, C-56 because the wiring harness is shorted to ground.
|
No
|
Go to the next step.
|
||
11
|
INSPECT FOR SHORT TO GROUND BETWEEN SAS CONTROL MODULE AND CONNECTORS C-55, C-56
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Go to the next step.
|
No
|
Repair or replace the wiring harness between the connectors C-55, C-56 and connector C-21 because the wiring harness is shorted to ground.
|
||
12
|
INSPECT CAN LINE IN SAS CONTROL MODULE FOR SHORT TO GROUND
• Disconnect the SAS control module connector.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between the SAS control module and connectors C-55, C-56 because the wiring harness is shorted to ground.
|
No
|
Replace the SAS control module because there is a short to ground in the SAS control module.
|
||
13
|
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-21 AND CONNECTOR C-07
• Connect the connector C-21.
• Disconnect the connector C-07.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between the connector C-21 and connector C-07 because the wiring harness is shorted to ground.
|
No
|
• Go to the next step. (with connectors C-37, C-36)
• Go to Step 18. (without connectors C-37, C-36)
|
||
14
|
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-07 AND CONNECTORS C-37, C-36
• Connect the connector C-07.
• Disconnect the connectors C-37, C-36.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between the connector C-07 and connectors C-37, C-36 because the wiring harness is shorted to ground.
|
No
|
Go to the next step.
|
||
15
|
INSPECT FOR SHORT TO GROUND BETWEEN DSC HU/CM AND CONNECTORS C-37, C-36
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Go to the next step.
|
No
|
Go to Step 17.
|
||
16
|
INSPECT CAN LINE IN DSC HU/CM FOR SHORT TO GROUND
• Disconnect the DSC HU/CM connector.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between the DSC HU/CM and connectors C-37, C-36 because the wiring harness is shorted to ground.
|
No
|
Replace the DSC HU/CM because there is a short to ground in the DSC HU/CM.
|
||
17
|
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTORS C-37, C-36 AND CONNECTOR C-02
• Connect the connectors C-37, C-36.
• Disconnect the connector C-02.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between the connectors C-37, C-36 and connector C-02 because the wiring harness is shorted to ground.
|
No
|
Go to Step 20.
|
||
18
|
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-02 AND CONNECTOR C-07
• Connect the connector C-07.
• Disconnect the connector C-02.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Go to the next step.
|
No
|
Go to Step 20.
|
||
19
|
INSPECT CAN LINE IN DSC HU/CM FOR SHORT TO GROUND
• Disconnect the DSC HU/CM connector.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between the connector C-07 and connector C-02 because the wiring harness is shorted to ground.
|
No
|
Replace the DSC HU/CM because there is a short to ground in the DSC HU/CM.
|
||
20
|
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-02 AND CONNECTOR C-38
• Connect the connector C-02.
• Disconnect the connector C-38.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between the connector C-02 and connector C-38 because the wiring harness is shorted to ground.
|
No
|
Go to the next step.
|
||
21
|
INSPECT FOR SHORT TO GROUND BETWEEN TCM AND CONNECTOR C-38
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Go to the next step.
|
No
|
Go to Step 23.
|
||
22
|
INSPECT CAN LINE IN TCM FOR SHORT TO GROUND
• Disconnect the TCM connector.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between the TCM and connector C-38 because the wiring harness is shorted to ground.
|
No
|
Replace the TCM because there is a short to ground in the TCM.
|
||
23
|
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-38 AND CONNECTOR C-01
• Connect the connector C-38.
• Disconnect the connector C-01.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between the connector C-38 and connector C-01 because the wiring harness is shorted to ground.
|
No
|
Go to the next step.
|
||
24
|
INSPECT CAN LINE IN PCM FOR SHORT TO GROUND
• Disconnect the PCM connector.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between the PCM and connector C-01 because the wiring harness is shorted to ground.
|
No
|
Replace the PCM because there is a short to ground in the PCM.
|