Menu +
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors

DETERMINING SHORT TO GROUND LOCATION (CAN-BUS No.1) [(US)]

DETERMINING SHORT TO GROUND LOCATION (CAN-BUS No.1) [(US)]

SM2566444


id1002x1001800

Caution
• Perform the following malfunction diagnosis only when it is diagnosed with a short to ground by CONTROLLER AREA NETWORK (CAN) MALFUNCTION DIAGNOSIS FLOW. (See CONTROLLER AREA NETWORK (CAN) MALFUNCTION DIAGNOSIS FLOW [(US)].)



System Wiring Diagram

am3zzw00027504



Determination Procedure

Caution
• When disconnecting the connector, verify that there is no looseness, damage, deformation, corrosion, or poor connection of the connector terminals.
• When inspecting the connector, touch it with a paper clip or similar thin pin without directly inserting a tester probe into the terminal.

Step

Inspection

Action

1
INSPECT FOR SHORT TO GROUND BETWEEN BODY CONTROL MODULE (BCM) AND CONNECTOR C-40
• Switch the ignition off.
• Disconnect the negative battery cable. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION [(US)])
• Disconnect the connector C-40.
• Inspect for continuity at the following terminals:
― Between body control module (BCM) terminal 3X and body ground
― Between body control module (BCM) terminal 3W and body ground
• Is there continuity?
Yes
Go to the next step.
No
Go to Step 3.
2
INSPECT CAN LINE IN BODY CONTROL MODULE (BCM) FOR SHORT TO GROUND
• Disconnect the connector 3 which has body control module (BCM) terminals 3X and 3W.
• Inspect for continuity at the following terminals:
― Between body control module (BCM) terminal 3X (wiring harness side) and body ground
― Between body control module (BCM) terminal 3W (wiring harness side) and body ground
• Is there continuity?
Yes
Repair or replace the wiring harness between the connector C-40 and body control module (BCM) because the wiring harness is shorted to ground.
No
Replace the body control module (BCM) because there is a short to ground in the body control module (BCM).
3
INSPECT FOR SHORT TO GROUND BETWEEN EPS CONTROL MODULE AND CONNECTOR C-40
• Inspect for continuity at the following terminals:
― Between EPS control module terminal 2C and body ground
― Between EPS control module terminal 2A and body ground
• Is there continuity?
Yes
Go to the next step.
No
Go to Step 5.
4
INSPECT CAN LINE IN EPS CONTROL MODULE FOR SHORT TO GROUND
• Disconnect the EPS control module connector.
• Inspect for continuity at the following terminals:
― Between EPS control module terminal 2C (wiring harness side) and body ground
― Between EPS control module terminal 2A (wiring harness side) and body ground
• Is there continuity?
Yes
Repair or replace the wiring harness between the EPS control module and connector C-40 because the wiring harness is shorted to ground.
No
Replace the EPS control module because there is a short to ground in the EPS control module.
5
INSPECT FOR SHORT TO GROUND BETWEEN AFS CONTROL MODULE / AUTO LEVELING CONTROL MODULE AND CONNECTOR C-40
• Inspect for continuity at the following terminals:
― Between AFS control module / auto leveling control module terminal I and body ground
― Between AFS control module / auto leveling control module terminal J and body ground
• Is there continuity?
Yes
Go to the next step.
No
Go to Step 7.
6
INSPECT CAN LINE IN AFS CONTROL MODULE / AUTO LEVELING CONTROL MODULE FOR SHORT TO GROUND
• Disconnect the AFS control module / auto leveling control module connector.
• Inspect for continuity at the following terminals:
― Between AFS control module / auto leveling control module terminal I (wiring harness side) and body ground
― Between AFS control module / auto leveling control module terminal J (wiring harness side) and body ground
• Is there continuity?
Yes
Repair or replace the wiring harness between the AFS control module / auto leveling control module and connector C-40 because the wiring harness is shorted to ground.
No
Replace the AFS control module / auto leveling control module because there is a short to ground in the AFS control module / auto leveling control module.
7
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-40 AND CONNECTOR C-13
• Connect the connector C-40.
• Disconnect the connector C-13.
• Inspect for continuity at the following terminals:
― Between body control module (BCM) terminal 3X and body ground
― Between body control module (BCM) terminal 3W and body ground
• Is there continuity?
Yes
Repair or replace the wiring harness between the connector C-40 and connector C-13 because the wiring harness is shorted to ground.
No
Go to the next step.
8
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-13 AND CONNECTOR C-21
• Connect the connector C-13.
• Disconnect the connector C-21.
• Inspect for continuity at the following terminals:
― Between body control module (BCM) terminal 3X and body ground
― Between body control module (BCM) terminal 3W and body ground
• Is there continuity?
Yes
Repair or replace the wiring harness between the connector C-13 and connector C-21 because the wiring harness is shorted to ground.
No
Go to the next step.
9
INSPECT FOR SHORT TO GROUND BETWEEN SAS CONTROL MODULE AND CONNECTOR C-21
• Inspect for continuity at the following terminals:
― Between SAS control module terminal 3A and body ground
― Between SAS control module terminal 3D and body ground
• Is there continuity?
Yes
Go to the next step.
No
Go to Step 13.
10
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-21 AND CONNECTORS C-55, C-56
• Disconnect the connectors C-55, C-56.
• Connect the connector C-21.
• Inspect for continuity at the following terminals:
― Between body control module (BCM) terminal 3X and body ground
― Between body control module (BCM) terminal 3W and body ground
• Is there continuity?
Yes
Repair or replace the wiring harness between the connector C-21 and connectors C-55, C-56 because the wiring harness is shorted to ground.
No
Go to the next step.
11
INSPECT FOR SHORT TO GROUND BETWEEN SAS CONTROL MODULE AND CONNECTORS C-55, C-56
• Inspect for continuity at the following terminals:
― Between SAS control module terminal 3A and body ground
― Between SAS control module terminal 3D and body ground
• Is there continuity?
Yes
Go to the next step.
No
Repair or replace the wiring harness between the connectors C-55, C-56 and connector C-21 because the wiring harness is shorted to ground.
12
INSPECT CAN LINE IN SAS CONTROL MODULE FOR SHORT TO GROUND
• Disconnect the SAS control module connector.
• Inspect for continuity at the following terminals:
― Between SAS control module terminal 3A (wiring harness side) and body ground
― Between SAS control module terminal 3D (wiring harness side) and body ground
• Is there continuity?
Yes
Repair or replace the wiring harness between the SAS control module and connectors C-55, C-56 because the wiring harness is shorted to ground.
No
Replace the SAS control module because there is a short to ground in the SAS control module.
13
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-21 AND CONNECTOR C-07
• Connect the connector C-21.
• Disconnect the connector C-07.
• Inspect for continuity at the following terminals:
― Between body control module (BCM) terminal 3X and body ground
― Between body control module (BCM) terminal 3W and body ground
• Is there continuity?
Yes
Repair or replace the wiring harness between the connector C-21 and connector C-07 because the wiring harness is shorted to ground.
No
• Go to the next step. (with connectors C-37, C-36)
• Go to Step 18. (without connectors C-37, C-36)
14
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-07 AND CONNECTORS C-37, C-36
• Connect the connector C-07.
• Disconnect the connectors C-37, C-36.
• Inspect for continuity at the following terminals:
― Between body control module (BCM) terminal 3X and body ground
― Between body control module (BCM) terminal 3W and body ground
• Is there continuity?
Yes
Repair or replace the wiring harness between the connector C-07 and connectors C-37, C-36 because the wiring harness is shorted to ground.
No
Go to the next step.
15
INSPECT FOR SHORT TO GROUND BETWEEN DSC HU/CM AND CONNECTORS C-37, C-36
• Inspect for continuity at the following terminals:
― Between DSC HU/CM terminal L and body ground
― Between DSC HU/CM terminal J and body ground
• Is there continuity?
Yes
Go to the next step.
No
Go to Step 17.
16
INSPECT CAN LINE IN DSC HU/CM FOR SHORT TO GROUND
• Disconnect the DSC HU/CM connector.
• Inspect for continuity at the following terminals:
― Between DSC HU/CM terminal L (wiring harness side) and body ground
― Between DSC HU/CM terminal J (wiring harness side) and body ground
• Is there continuity?
Yes
Repair or replace the wiring harness between the DSC HU/CM and connectors C-37, C-36 because the wiring harness is shorted to ground.
No
Replace the DSC HU/CM because there is a short to ground in the DSC HU/CM.
17
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTORS C-37, C-36 AND CONNECTOR C-02
• Connect the connectors C-37, C-36.
• Disconnect the connector C-02.
• Inspect for continuity at the following terminals:
― Between body control module (BCM) terminal 3X and body ground
― Between body control module (BCM) terminal 3W and body ground
• Is there continuity?
Yes
Repair or replace the wiring harness between the connectors C-37, C-36 and connector C-02 because the wiring harness is shorted to ground.
No
Go to Step 20.
18
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-02 AND CONNECTOR C-07
• Connect the connector C-07.
• Disconnect the connector C-02.
• Inspect for continuity at the following terminals:
― Between body control module (BCM) terminal 3X and body ground
― Between body control module (BCM) terminal 3W and body ground
• Is there continuity?
Yes
Go to the next step.
No
Go to Step 20.
19
INSPECT CAN LINE IN DSC HU/CM FOR SHORT TO GROUND
• Disconnect the DSC HU/CM connector.
• Inspect for continuity at the following terminals:
― Between DSC HU/CM terminal L (wiring harness side) and body ground
― Between DSC HU/CM terminal J (wiring harness side) and body ground
• Is there continuity?
Yes
Repair or replace the wiring harness between the connector C-07 and connector C-02 because the wiring harness is shorted to ground.
No
Replace the DSC HU/CM because there is a short to ground in the DSC HU/CM.
20
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-02 AND CONNECTOR C-38
• Connect the connector C-02.
• Disconnect the connector C-38.
• Inspect for continuity at the following terminals:
― Between body control module (BCM) terminal 3X and body ground
― Between body control module (BCM) terminal 3W and body ground
• Is there continuity?
Yes
Repair or replace the wiring harness between the connector C-02 and connector C-38 because the wiring harness is shorted to ground.
No
Go to the next step.
21
INSPECT FOR SHORT TO GROUND BETWEEN TCM AND CONNECTOR C-38
• Inspect for continuity at the following terminals:
― Between TCM terminal E and body ground
― Between TCM terminal F and body ground
• Is there continuity?
Yes
Go to the next step.
No
Go to Step 23.
22
INSPECT CAN LINE IN TCM FOR SHORT TO GROUND
• Disconnect the TCM connector.
• Inspect for continuity at the following terminals:
― Between TCM terminal E (wiring harness side) and body ground
― Between TCM terminal F (wiring harness side) and body ground
• Is there continuity?
Yes
Repair or replace the wiring harness between the TCM and connector C-38 because the wiring harness is shorted to ground.
No
Replace the TCM because there is a short to ground in the TCM.
23
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-38 AND CONNECTOR C-01
• Connect the connector C-38.
• Disconnect the connector C-01.
• Inspect for continuity at the following terminals:
― Between body control module (BCM) terminal 3X and body ground
― Between body control module (BCM) terminal 3W and body ground
• Is there continuity?
Yes
Repair or replace the wiring harness between the connector C-38 and connector C-01 because the wiring harness is shorted to ground.
No
Go to the next step.
24
INSPECT CAN LINE IN PCM FOR SHORT TO GROUND
• Disconnect the PCM connector.
• Inspect for continuity at the following terminals:
― Between PCM terminal 2S (wiring harness side) and body ground
― Between PCM terminal 2T (wiring harness side) and body ground
• Is there continuity?
Yes
Repair or replace the wiring harness between the PCM and connector C-01 because the wiring harness is shorted to ground.
No
Replace the PCM because there is a short to ground in the PCM.