HEATED OXYGEN SENSOR (HO2S) HEATER CONTROL [SKYACTIV-G (WITHOUT CYLINDER DEACTIVATION (US))]
HEATED OXYGEN SENSOR (HO2S) HEATER CONTROL [SKYACTIV-G (WITHOUT CYLINDER DEACTIVATION (US))]
SM2565352
id0140u0785600
Outline
Block Diagram
| 
 am3zzn00008281 | 
Operation
| Output duty ratio | Control condition | 
|---|---|
| 0% | • Engine stopped (excludes engine stop by i-stop control) • Fuel cut injection control is in engine start zone • Engine coolant temperature is -10 °C {14 °F}or less • Other than battery voltage of 9—16 V • Within a fixed period of time after engine start (varies according to engine coolant temperature) | 
| 0―100% (Duty ratio determined by measuring the element temperature by the HO2S sensor heater element impedance) | • After engine warm-up (value fluctuates by battery condition, etc.) | 