{"id":8301,"date":"2017-06-11T23:56:43","date_gmt":"2017-06-11T23:56:43","guid":{"rendered":"http:\/\/mazdaman.x10host.com\/sh13009\/"},"modified":"2017-06-11T23:56:43","modified_gmt":"2017-06-11T23:56:43","slug":"sh13009","status":"publish","type":"page","link":"https:\/\/www.hexorcism.com\/16ND\/sh13009\/","title":{"rendered":"ELECTRIC VARIABLE VALVE TIMING RELAY [SKYACTIV-G 2.0]"},"content":{"rendered":"<div class=\"node node SERVICE_HIGHLIGHTS\">\n    <\/p>\n<div class=\"textleft\">\n<div class=\"attr CONTENT c1\">\n<div class=\"content\">\n          <link rel=\"stylesheet\" type=\"text\/css\" href=\"style.css\" media=\"screen\"><a class=\"prevPage\" href=\"SH13008\">&lt; Previous<\/a> <a class=\"nextPage\" href=\"SH13010\">Next &gt;<\/a><\/p>\n<h2>2016 &#8211; MX-5 &#8211; Engine<\/h2>\n<p><a name=\"id0110h2198600\" id=\"id0110h2198600\"><\/a><\/p>\n<h3>ELECTRIC VARIABLE VALVE TIMING RELAY [SKYACTIV-G 2.0]<\/h3>\n<p><a name=\"id0110h219860001\" id=\"id0110h219860001\"><\/a><\/p>\n<h4>Purpose, Function<\/h4>\n<ul type=\"disc\">\n<li>\n<p>The electric variable valve timing relay operates by the battery voltage after main relay energization, and supplies battery voltage to the electric variable timing motor\/driver.<\/p>\n<\/li>\n<\/ul>\n<p>          <a name=\"id0110h219860002\" id=\"id0110h219860002\"><\/a><\/p>\n<h4>Construction<\/h4>\n<ul type=\"disc\">\n<li>\n<p>The electric variable valve timing relay is located on the relay and fuse block.<\/p>\n<p align=\"center\"><a href=\"\/16ND\/wp-content\/uploads\/2017\/05\/AMXUUN00001575.GIF\"><img decoding=\"async\" align=\"absmiddle\" border=\"0\" src=\"\/16ND\/wp-content\/uploads\/2017\/05\/AMXUUN00001575.GIF\"><\/a><\/p>\n<\/li>\n<\/ul>\n<ul type=\"disc\">\n<li>\n<p>A normally open relay has been adopted for the electric variable valve timing relay.<\/p>\n<\/li>\n<li>\n<p>When electric current flows to the coil, the contact point is attracted by the generated electromagnetic power and switches on.<\/p>\n<p align=\"center\"><a href=\"\/16ND\/wp-content\/uploads\/2017\/05\/ARDJJN00001688.GIF\"><img decoding=\"async\" align=\"absmiddle\" border=\"0\" src=\"\/16ND\/wp-content\/uploads\/2017\/05\/ARDJJN00001688.GIF\"><\/a><\/p>\n<\/li>\n<\/ul>\n<p>          <a name=\"id0110h219860003\" id=\"id0110h219860003\"><\/a><\/p>\n<h4>Operation<\/h4>\n<p>            1. Flows (1) electric current to the main relay coil based on the signals from the PCM.<\/p>\n<p>            2. When electric current flows to the coil, the contact point is attracted by the generated electromagnetic power and switches on (2).<\/p>\n<p>            3. When the contact point switches on, the battery power supply flows (3) electric current to the electric variable valve timing relay.<\/p>\n<p>            4. When electric current flows to the coil, the contact point is attracted by the generated electromagnetic power and switches on (4).<\/p>\n<p>            5. When the contact point switches on, the battery power supply flows (5) electric current to the electric variable valve timing motor\/driver.<\/p>\n<p align=\"center\"><a href=\"\/16ND\/wp-content\/uploads\/2017\/05\/AMXUUN00001135.GIF\"><img decoding=\"async\" align=\"absmiddle\" border=\"0\" src=\"\/16ND\/wp-content\/uploads\/2017\/05\/AMXUUN00001135.GIF\"><\/a><\/p>\n<p>          <a name=\"id0110h219860004\" id=\"id0110h219860004\"><\/a><\/p>\n<h4>Fail-safe<\/h4>\n<table border=\"1\" cellpadding=\"0\" cellspacing=\"@colsep\" bordercolor=\"#CCCCCC\" frame=\"box\" rules=\"all\">\n<tbody valign=\"\" cellspacing=\"1\" rowspan=\"\">\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>DTC<\/p>\n<\/td>\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Fail-safe<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>P0010:00<\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<ul type=\"disc\">\n<li>\n<p>Stops activation of the electric variable valve timing driver.<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\n          <a class=\"prevPage\" href=\"SH13008\">&lt; Previous<\/a> <a class=\"nextPage\" href=\"SH13010\">Next &gt;<\/a><\/p>\n<div align=\"right\">\n            <a href=\"\"#\">Back to Top<\/a>\n          <\/div>\n<div align=\"center\">\n            <em>\u00a9 2014 Mazda North American Operations, U.S.A.<\/em>\n          <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n","protected":false},"excerpt":{"rendered":"<p>&lt; Previous Next &gt; 2016 &#8211; MX-5 &#8211; Engine ELECTRIC VARIABLE VALVE TIMING RELAY [SKYACTIV-G 2.0] Purpose, Function The electric variable valve timing relay operates by the battery voltage after main relay energization, and supplies battery voltage to the electric variable timing motor\/driver. Construction The electric variable valve timing relay is located on the relay and fuse block. A normally open relay has been adopted for the electric variable valve timing relay. When electric current [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-8301","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.hexorcism.com\/16ND\/wp-json\/wp\/v2\/pages\/8301","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hexorcism.com\/16ND\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.hexorcism.com\/16ND\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/16ND\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hexorcism.com\/16ND\/wp-json\/wp\/v2\/comments?post=8301"}],"version-history":[{"count":0,"href":"https:\/\/www.hexorcism.com\/16ND\/wp-json\/wp\/v2\/pages\/8301\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.hexorcism.com\/16ND\/wp-json\/wp\/v2\/media?parent=8301"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}