DTC U2300:56 [INSTRUMENT CLUSTER]

< Previous Next >

2016 – MX-5 – Body and Accessories

DTC U2300:56 [INSTRUMENT CLUSTER]

Description

Instrument cluster configuration error

Detection condition

  • Instrument cluster configuration error (incorrect value write) detected.

Fail-safe

Not applicable

Possible cause

  • Instrument cluster configuration error

  • Instrument cluster malfunction

System wiring diagram

Not applicable

Diagnostic Procedure

Step

Inspection

Action

1

PERFORM INSTRUMENT CLUSTER CONFIGURATION (USING AS-BUILT DATA)

Yes

Using the M-MDS, perform the instrument cluster configuration (using As-Built data) again, then go to the next step.

(See INSTRUMENT CLUSTER CONFIGURATION (USING AS-BUILT DATA).)

No

Go to Step 3.

2

VERIFY THAT REPAIRS HAVE BEEN COMPLETED

Yes

Replace the instrument cluster, then go to the next step.

(See INSTRUMENT CLUSTER REMOVAL/INSTALLATION.)

No

Go to the next step.

3

VERIFY IF OTHER DTCs DISPLAYED

  • Are any other DTCs displayed?

Yes

Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.

(See DTC TABLE [INSTRUMENT CLUSTER].)

No

DTC troubleshooting completed.