DTC U0401:68 [INSTRUMENT CLUSTER]

< Previous Next >

2016 – MX-5 – Body and Accessories

DTC U0401:68 [INSTRUMENT CLUSTER]

Description

Error signal received from PCM

Detection condition

  • Instrument cluster receives the error signals from the PCM with the ignition switched ON (engine off or on).

Fail-safe

Not applicable

Possible cause

  • DTCs are stored in the PCM.

  • PCM malfunction

  • Instrument cluster malfunction

System wiring diagram

Not applicable

Diagnostic Procedure

Step

Inspection

Action

1

VERIFY PCM DTCs

Yes

Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.

(See DTC TABLE [PCM (SKYACTIV-G 2.0)].)

No

Go to the next step.

2

VERIFY IF MALFUNCTIONING LOCATION IS PCM DEPENDING ON REPEATABILITY

Yes

Replace the PCM, then go to the next step.

(See PCM REMOVAL/INSTALLATION [SKYACTIV-G 2.0].)

No

Go to Step 4.

3

VERIFY THAT REPAIRS HAVE BEEN COMPLETED

Yes

Replace the instrument cluster, then go to the next step.

(See INSTRUMENT CLUSTER REMOVAL/INSTALLATION.)

No

Go to the next step.

4

VERIFY IF OTHER DTCs DISPLAYED

  • Are any other DTCs displayed?

Yes

Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.

(See DTC TABLE [INSTRUMENT CLUSTER].)

No

DTC troubleshooting completed.

< Previous Next >

© 2014 Mazda North American Operations, U.S.A.