Menu +
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors

DTC P0615:12 [START STOP UNIT]

< Previous Next >

2016 – MX-5 – Body and Accessories

DTC P0615:12 [START STOP UNIT]

Description

Starter relay circuit malfunction

Detection condition

  • Start stop unit detects that the starter relay circuit voltage of specification or more for 0.1 s or more with the ignition switched off.

Fail-safe

  • Inhibits switching the ignition ON (engine off or on).

  • Inhibits the engine start.

Possible cause

  • DTCs are stored in the PCM.

  • Starter relay malfunction

  • Start stop unit connector or terminal malfunction

  • PCM connector malfunction

  • Short to power supply in wiring harness between the following terminals:

    • Start stop unit terminal 1D—Starter relay terminal E

    • Starter relay terminal E—PCM terminal 2AZ

    • Start stop unit terminal 2V—Starter relay terminal A

  • PCM malfunction

  • Start stop unit malfunction

Diagnostic Procedure

Step

Inspection

Action

1

VERIFY PCM DTCs

Yes

Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.

(See DTC TABLE [PCM (SKYACTIV-G 2.0)].)

No

Go to the next step.

2

INSPECT STARTER RELAY

Yes

Go to the next step.

No

Replace the starter relay, then go to Step 7.

(See RELAY LOCATION.)

3

INSPECT START STOP UNIT CONNECTOR CONDITION

  • Disconnect the start stop unit connector.

  • Inspect the connector engagement and connection condition and inspect the terminals for damage, deformation, corrosion, or disconnection.

  • Is the connector normal?

Yes

Go to the next step.

No

Repair or replace the connector, then go to Step 7.

4

INSPECT PCM CONNECTOR CONDITION

  • Disconnect the PCM connector.

  • Inspect the connector engagement and connection condition and inspect the terminals for damage, deformation, corrosion, or disconnection.

  • Is the connector normal?

Yes

Go to the next step.

No

Repair or replace the connector, then go to Step 7.

5

INSPECT STARTER RELAY CIRCUIT FOR SHORT TO POWER SUPPLY

  • Verify that the starter relay is removed.

  • Verify that the start stop unit and PCM connectors are disconnected.

  • Connect the negative battery cable.

    (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION.)

  • Measure the voltage at the following terminals (wiring harness-side):

    • Start stop unit terminal 1D

    • Start stop unit terminal 2V

  • Is the voltage 0 V?

Yes

Go to the next step.

No

Refer to the wiring diagram and verify whether or not there is a common connector between the following terminals:

  • Start stop unit terminal 1D—Starter relay terminal E

  • Starter relay terminal E—PCM terminal 2AZ

  • Start stop unit terminal 2V—Starter relay terminal A

    If there is a common connector:

  • Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to power supply.

  • Repair or replace the malfunctioning part.

    If there is no common connector:

  • Repair or replace the wiring harness which has a short to power supply.

Go to Step 7.

6

VERIFY IF MALFUNCTIONING LOCATION IS PCM DEPENDING ON REPEATABILITY

Yes

Replace the PCM, then go to the next step.

(See PCM REMOVAL/INSTALLATION [SKYACTIV-G 2.0].)

No

Go to Step 8.

7

VERIFY THAT REPAIRS HAVE BEEN COMPLETED

Yes

Repeat the inspection from Step 1.

Go to the next step.

No

Go to the next step.

8

VERIFY IF OTHER DTCs DISPLAYED

  • Are any other DTCs displayed?

Yes

Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.

(See DTC TABLE [START STOP UNIT].)

No

DTC troubleshooting completed.

< Previous Next >