Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors

DTC U200D:11 [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)]

< Previous Next >

2016 – MX-5 – HVAC

DTC U200D:11 [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)]

System malfunction location

  • Climate control unit circuit voltage (+5V) circuit short to ground

Detection condition

  • Malfunction in wiring harness between climate control unit circuit voltage (+5V) and each sensor/actuator

Fail-safe function

Not applicable

Possible cause

  • Connector or terminal malfunction

  • Each actuator malfunction

  • Short to ground in wiring harness between climate control unit and air mix actuator

  • Short to ground in wiring harness between climate control unit and airflow mode actuator

  • Climate control unit malfunction

Diagnostic procedure

STEP

INSPECTION

ACTION

1

VERIFY CLIMATE CONTROL UNIT CONNECTOR CONDITION

Yes

Go to the next step.

No

Repair/replace the malfunctioning vehicle wiring harness, connector, or terminal.

After repair procedure, go to the next step.

2

VERIFY CONNECTOR CONDITION

Yes

Go to the next step.

No

Replace the malfunctioning part.

(See AIR MIX ACTUATOR REMOVAL/INSTALLATION [MANUAL AIR CONDITIONER].)

(See AIRFLOW MODE ACTUATOR REMOVAL/INSTALLATION [MANUAL AIR CONDITIONER].)

After replace procedure, go to the next step.

3

INSPECT EACH SENSOR/ACTUATOR

Yes

Go to the next step.

No

Replace the malfunctioning sensor/actuator.

(See AIR MIX ACTUATOR REMOVAL/INSTALLATION [MANUAL AIR CONDITIONER].)

(See AIRFLOW MODE ACTUATOR REMOVAL/INSTALLATION [MANUAL AIR CONDITIONER].)

After replace procedure, go to the next step.

4

INSPECT EACH SENSOR/ACTUATOR CIRCUIT FOR SHORT TO GROUND

  • Inspect for continuity between the following terminal (wiring harness-side) and body ground:

    • Climate control unit terminal H

  • Is there continuity?

Yes

Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal H and each sensor/actuator terminals.

    If there is a common connector:

  • Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to ground.

  • Repair or replace the malfunctioning part.

    If there is no common connector:

  • Repair or replace the wiring harness which has a short to ground.

Go to the next step.

No

Go to the next step.

5

VERIFY THAT SAME DTC IS NOT OUTPUT AGAIN

Yes

Repeat the inspection from Step 1.

Go to the next step.

No

Go to the next step.

6

VERIFY THAT NO OTHER DTCs ARE PRESENT

Yes

Perform the corresponding DTC inspection.

(See DTC TABLE [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)].)

No

DTC troubleshooting completed.

< Previous Next >

© 2014 Mazda North American Operations, U.S.A.